These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

307 related articles for article (PubMed ID: 26386850)

  • 1. Ten-Year Follow-up of a Blind Patient Chronically Implanted with Epiretinal Prosthesis Argus I.
    Yue L; Falabella P; Christopher P; Wuyyuru V; Dorn J; Schor P; Greenberg RJ; Weiland JD; Humayun MS
    Ophthalmology; 2015 Dec; 122(12):2545-52.e1. PubMed ID: 26386850
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Long-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind.
    Ho AC; Humayun MS; Dorn JD; da Cruz L; Dagnelie G; Handa J; Barale PO; Sahel JA; Stanga PE; Hafezi F; Safran AB; Salzmann J; Santos A; Birch D; Spencer R; Cideciyan AV; de Juan E; Duncan JL; Eliott D; Fawzi A; Olmos de Koo LC; Brown GC; Haller JA; Regillo CD; Del Priore LV; Arditi A; Geruschat DR; Greenberg RJ;
    Ophthalmology; 2015 Aug; 122(8):1547-54. PubMed ID: 26162233
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interim results from the international trial of Second Sight's visual prosthesis.
    Humayun MS; Dorn JD; da Cruz L; Dagnelie G; Sahel JA; Stanga PE; Cideciyan AV; Duncan JL; Eliott D; Filley E; Ho AC; Santos A; Safran AB; Arditi A; Del Priore LV; Greenberg RJ;
    Ophthalmology; 2012 Apr; 119(4):779-88. PubMed ID: 22244176
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Retina-electrode interface properties and vision restoration by two generations of retinal prostheses in one patient-one in each eye.
    Yue L; Wuyyuru V; Gonzalez-Calle A; Dorn JD; Humayun MS
    J Neural Eng; 2020 Apr; 17(2):026020. PubMed ID: 32131056
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Factors affecting perceptual thresholds in epiretinal prostheses.
    de Balthasar C; Patel S; Roy A; Freda R; Greenwald S; Horsager A; Mahadevappa M; Yanai D; McMahon MJ; Humayun MS; Greenberg RJ; Weiland JD; Fine I
    Invest Ophthalmol Vis Sci; 2008 Jun; 49(6):2303-14. PubMed ID: 18515576
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temporal properties of visual perception on electrical stimulation of the retina.
    Pérez Fornos A; Sommerhalder J; da Cruz L; Sahel JA; Mohand-Said S; Hafezi F; Pelizzone M
    Invest Ophthalmol Vis Sci; 2012 May; 53(6):2720-31. PubMed ID: 22447863
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Perceptual thresholds and electrode impedance in three retinal prosthesis subjects.
    Mahadevappa M; Weiland JD; Yanai D; Fine I; Greenberg RJ; Humayun MS
    IEEE Trans Neural Syst Rehabil Eng; 2005 Jun; 13(2):201-6. PubMed ID: 16003900
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Detection of Motion by Blind Subjects With the Epiretinal 60-Electrode (Argus II) Retinal Prosthesis.
    Dorn JD; Ahuja AK; Caspi A; da Cruz L; Dagnelie G; Sahel JA; Greenberg RJ; McMahon MJ;
    JAMA Ophthalmol; 2013 Feb; 131(2):183-9. PubMed ID: 23544203
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Restoring Color Perception to the Blind: An Electrical Stimulation Strategy of Retina in Patients with End-stage Retinitis Pigmentosa.
    Yue L; Castillo J; Gonzalez AC; Neitz J; Humayun MS
    Ophthalmology; 2021 Mar; 128(3):453-462. PubMed ID: 32858064
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term Repeatability and Reproducibility of Phosphene Characteristics in Chronically Implanted Argus II Retinal Prosthesis Subjects.
    Luo YH; Zhong JJ; Clemo M; da Cruz L
    Am J Ophthalmol; 2016 Oct; 170():100-109. PubMed ID: 27491695
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-term histological and electrophysiological results of an inactive epiretinal electrode array implantation in dogs.
    Majji AB; Humayun MS; Weiland JD; Suzuki S; D'Anna SA; de Juan E
    Invest Ophthalmol Vis Sci; 1999 Aug; 40(9):2073-81. PubMed ID: 10440263
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Five-Year Safety and Performance Results from the Argus II Retinal Prosthesis System Clinical Trial.
    da Cruz L; Dorn JD; Humayun MS; Dagnelie G; Handa J; Barale PO; Sahel JA; Stanga PE; Hafezi F; Safran AB; Salzmann J; Santos A; Birch D; Spencer R; Cideciyan AV; de Juan E; Duncan JL; Eliott D; Fawzi A; Olmos de Koo LC; Ho AC; Brown G; Haller J; Regillo C; Del Priore LV; Arditi A; Greenberg RJ;
    Ophthalmology; 2016 Oct; 123(10):2248-54. PubMed ID: 27453256
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The first deaf-blind patient in Russia with Argus II retinal prosthesis system: what he sees and why.
    Demchinsky AM; Shaimov TB; Goranskaya DN; Moiseeva IV; Kuznetsov DI; Kuleshov DS; Polikanov DV
    J Neural Eng; 2019 Apr; 16(2):025002. PubMed ID: 30620937
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Brightness as a function of current amplitude in human retinal electrical stimulation.
    Greenwald SH; Horsager A; Humayun MS; Greenberg RJ; McMahon MJ; Fine I
    Invest Ophthalmol Vis Sci; 2009 Nov; 50(11):5017-25. PubMed ID: 19608533
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical coherence tomography imaging in the management of the Argus II retinal prosthesis system.
    Parmeggiani F; De Nadai K; Piovan A; Binotto A; Zamengo S; Chizzolini M
    Eur J Ophthalmol; 2017 Jan; 27(1):e16-e21. PubMed ID: 28009400
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stimulation with a wireless intraocular epiretinal implant elicits visual percepts in blind humans.
    Klauke S; Goertz M; Rein S; Hoehl D; Thomas U; Eckhorn R; Bremmer F; Wachtler T
    Invest Ophthalmol Vis Sci; 2011 Jan; 52(1):449-55. PubMed ID: 20861492
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electrically elicited visual evoked potentials in Argus II retinal implant wearers.
    Stronks HC; Barry MP; Dagnelie G
    Invest Ophthalmol Vis Sci; 2013 Jun; 54(6):3891-901. PubMed ID: 23611993
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Clinical Results after Implantation of Epiretinal Visual Prostheses].
    Schimitzek H; Roessler G; Walter P
    Klin Monbl Augenheilkd; 2016 Nov; 233(11):1227-1232. PubMed ID: 27676329
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Argus(®) II Retinal Prosthesis System.
    Luo YH; da Cruz L
    Prog Retin Eye Res; 2016 Jan; 50():89-107. PubMed ID: 26404104
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Implantation and explantation of a wireless epiretinal retina implant device: observations during the EPIRET3 prospective clinical trial.
    Roessler G; Laube T; Brockmann C; Kirschkamp T; Mazinani B; Goertz M; Koch C; Krisch I; Sellhaus B; Trieu HK; Weis J; Bornfeld N; Röthgen H; Messner A; Mokwa W; Walter P
    Invest Ophthalmol Vis Sci; 2009 Jun; 50(6):3003-8. PubMed ID: 19420330
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.