These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 26387117)

  • 1. Randomized comparison of contact force-guided versus conventional circumferential pulmonary vein isolation of atrial fibrillation: prevalence, characteristics, and predictors of electrical reconnections and clinical outcomes.
    Nakamura K; Naito S; Sasaki T; Nakano M; Minami K; Nakatani Y; Ikeda K; Yamashita E; Kumagai K; Funabashi N; Oshima S
    J Interv Card Electrophysiol; 2015 Dec; 44(3):235-45. PubMed ID: 26387117
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predictors of chronic pulmonary vein reconnections after contact force-guided ablation: importance of completing electrical isolation with circumferential lines and creating sufficient ablation lesion densities.
    Nakamura K; Naito S; Sasaki T; Minami K; Take Y; Shimizu S; Yamaguchi Y; Yano T; Senga M; Yamashita E; Sugai Y; Kumagai K; Funabashi N; Oshima S
    J Interv Card Electrophysiol; 2016 Dec; 47(3):321-331. PubMed ID: 27417148
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation.
    Itoh T; Kimura M; Tomita H; Sasaki S; Owada S; Horiuchi D; Sasaki K; Ishida Y; Kinjo T; Okumura K
    Europace; 2016 Apr; 18(4):531-7. PubMed ID: 26346921
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation.
    Makimoto H; Heeger CH; Lin T; Rillig A; Metzner A; Wissner E; Mathew S; Deiss S; Rausch P; Lemeš C; Kuck KH; Ouyang F; Tilz RR
    Clin Res Cardiol; 2015 Oct; 104(10):861-70. PubMed ID: 25893569
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized Study.
    Pedrote A; Arana-Rueda E; Arce-León A; Acosta J; Gómez-Pulido F; Martos-Maine JL; Frutos-López M; Sánchez-Brotons J; García-Riesco L
    Pacing Clin Electrophysiol; 2016 Apr; 39(4):361-9. PubMed ID: 26768692
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Three-year outcomes and reconnection patterns after initial contact force guided pulmonary vein isolation for paroxysmal atrial fibrillation.
    Nair GM; Yeo C; MacDonald Z; Ainslie MP; Alqarawi WA; Nery PB; Redpath CJ; Sadek M; Spence S; Green MS; Birnie DH
    J Cardiovasc Electrophysiol; 2017 Sep; 28(9):984-993. PubMed ID: 28635046
    [TBL] [Abstract][Full Text] [Related]  

  • 7. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation.
    Kautzner J; Neuzil P; Lambert H; Peichl P; Petru J; Cihak R; Skoda J; Wichterle D; Wissner E; Yulzari A; Kuck KH
    Europace; 2015 Aug; 17(8):1229-35. PubMed ID: 26041872
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures.
    Ciconte G; Velagić V; Mugnai G; Saitoh Y; Irfan G; Hunuk B; Ströker E; Conte G; Sieira J; Di Giovanni G; Baltogiannis G; Brugada P; de Asmundis C; Chierchia GB
    Europace; 2016 Jan; 18(1):71-7. PubMed ID: 26445821
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical utility of automated ablation lesion tagging based on catheter stability information (VisiTag Module of the CARTO 3 System) with contact force-time integral during pulmonary vein isolation for atrial fibrillation.
    Okumura Y; Watanabe I; Iso K; Nagashima K; Sonoda K; Sasaki N; Kogawa R; Takahashi K; Ohkubo K; Nakai T; Nakahara S; Hori Y; Hirayama A
    J Interv Card Electrophysiol; 2016 Nov; 47(2):245-252. PubMed ID: 27278517
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: a prospective, randomized study.
    Kimura M; Sasaki S; Owada S; Horiuchi D; Sasaki K; Itoh T; Ishida Y; Kinjo T; Tomita H; Okumura K
    Heart Rhythm; 2014 Jun; 11(6):984-91. PubMed ID: 24657428
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Superior efficacy of pulmonary vein isolation with online contact force measurement persists after the learning period: a prospective case control study.
    Wolf M; Saenen JB; Bories W; Miljoen HP; Nullens S; Vrints CJ; Sarkozy A
    J Interv Card Electrophysiol; 2015 Sep; 43(3):287-96. PubMed ID: 25956480
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Additional linear ablation from the superior vena cava to right atrial septum after pulmonary vein isolation improves the clinical outcome in patients with paroxysmal atrial fibrillation: prospective randomized study.
    Kang KW; Pak HN; Park J; Park JG; Uhm JS; Joung B; Lee MH; Hwang C
    Europace; 2014 Dec; 16(12):1738-45. PubMed ID: 25336668
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantitative Analysis of the Isolation Area During the Chronic Phase After a 28-mm Second-Generation Cryoballoon Ablation Demarcated by High-Resolution Electroanatomic Mapping.
    Miyazaki S; Taniguchi H; Hachiya H; Nakamura H; Takagi T; Iwasawa J; Hirao K; Iesaka Y
    Circ Arrhythm Electrophysiol; 2016 May; 9(5):e003879. PubMed ID: 27146418
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Duty-cycled multi-electrode radiofrequency vs. conventional irrigated point-by-point radiofrequency ablation for recurrent atrial fibrillation: comparative 3-year data.
    De Greef Y; Buysschaert I; Schwagten B; Stockman D; Tavernier R; Duytschaever M
    Europace; 2014 Jun; 16(6):820-5. PubMed ID: 24443035
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pulmonary vein isolation to treat paroxysmal atrial fibrillation: conventional versus multi-electrode radiofrequency ablation.
    Beukema RJ; Elvan A; Smit JJ; Delnoy PP; Misier AR; Reddy V
    J Interv Card Electrophysiol; 2012 Aug; 34(2):143-52. PubMed ID: 22354772
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pulmonary vein isolation combined with superior vena cava isolation for atrial fibrillation ablation: a prospective randomized study.
    Wang XH; Liu X; Sun YM; Shi HF; Zhou L; Gu JN
    Europace; 2008 May; 10(5):600-5. PubMed ID: 18442966
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison Between Contact Force Monitoring and Unipolar Signal Modification as a Guide for Catheter Ablation of Atrial Fibrillation: Prospective Multi-Center Randomized Study.
    Ejima K; Kato K; Okada A; Wakisaka O; Kimura R; Ishizawa M; Imai T; Toyama Y; Shoda M; Hagiwara N
    Circ Arrhythm Electrophysiol; 2019 Aug; 12(8):e007311. PubMed ID: 31345092
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results.
    Marijon E; Fazaa S; Narayanan K; Guy-Moyat B; Bouzeman A; Providencia R; Treguer F; Combes N; Bortone A; Boveda S; Combes S; Albenque JP
    J Cardiovasc Electrophysiol; 2014 Feb; 25(2):130-7. PubMed ID: 24433324
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical recurrence and electrical pulmonary vein reconnections after second-generation cryoballoon ablation.
    Miyazaki S; Taniguchi H; Hachiya H; Nakamura H; Takagi T; Hirao K; Iesaka Y
    Heart Rhythm; 2016 Sep; 13(9):1852-7. PubMed ID: 27241352
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation.
    le Polain de Waroux JB; Weerasooriya R; Anvardeen K; Barbraud C; Marchandise S; De Meester C; Goesaert C; Reis I; Scavee C
    Europace; 2015 Jun; 17(6):877-83. PubMed ID: 25618742
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.