These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 26388481)

  • 1. Examination of segmental average mass spectra from liquid chromatography-tandem mass spectrometric (LC-MS/MS) data enables screening of multiple types of protein modifications.
    Liu NY; Lee HH; Chang ZF; Tsay YG
    Anal Chim Acta; 2015 Sep; 892():115-22. PubMed ID: 26388481
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection and identification of heme c-modified peptides by histidine affinity chromatography, high-performance liquid chromatography-mass spectrometry, and database searching.
    Merkley ED; Anderson BJ; Park J; Belchik SM; Shi L; Monroe ME; Smith RD; Lipton MS
    J Proteome Res; 2012 Dec; 11(12):6147-58. PubMed ID: 23082897
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous quantification of protein phosphorylation sites using liquid chromatography-tandem mass spectrometry-based targeted proteomics: a linear algebra approach for isobaric phosphopeptides.
    Xu F; Yang T; Sheng Y; Zhong T; Yang M; Chen Y
    J Proteome Res; 2014 Dec; 13(12):5452-60. PubMed ID: 25403019
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Strategy for comprehensive identification of post-translational modifications in cellular proteins, including low abundant modifications: application to glyceraldehyde-3-phosphate dehydrogenase.
    Seo J; Jeong J; Kim YM; Hwang N; Paek E; Lee KJ
    J Proteome Res; 2008 Feb; 7(2):587-602. PubMed ID: 18183946
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Extended Range Proteomic Analysis (ERPA): a new and sensitive LC-MS platform for high sequence coverage of complex proteins with extensive post-translational modifications-comprehensive analysis of beta-casein and epidermal growth factor receptor (EGFR).
    Wu SL; Kim J; Hancock WS; Karger B
    J Proteome Res; 2005; 4(4):1155-70. PubMed ID: 16083266
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comprehensive Protocol to Simultaneously Study Protein Phosphorylation, Acetylation, and N-Linked Sialylated Glycosylation.
    Melo-Braga MN; Ibáñez-Vea M; Kulej K; Larsen MR
    Methods Mol Biol; 2021; 2261():55-72. PubMed ID: 33420984
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mining phosphopeptide signals in liquid chromatography-mass spectrometry data for protein phosphorylation analysis.
    Wu HY; Tseng VS; Liao PC
    J Proteome Res; 2007 May; 6(5):1812-21. PubMed ID: 17402769
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Applying 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) for systematic toxicological analysis with liquid chromatography-high-resolution tandem mass spectrometry.
    Arnhard K; Gottschall A; Pitterl F; Oberacher H
    Anal Bioanal Chem; 2015 Jan; 407(2):405-14. PubMed ID: 25366975
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Post-translational modifications of Desulfovibrio vulgaris Hildenborough sulfate reduction pathway proteins.
    Gaucher SP; Redding AM; Mukhopadhyay A; Keasling JD; Singh AK
    J Proteome Res; 2008 Jun; 7(6):2320-31. PubMed ID: 18416566
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Targeted identification of phosphorylated peptides by off-line HPLC-MALDI-MS/MS using LC retention time prediction.
    Chen VC; Chou CC; Hsieh HY; Perreault H; Khoo KH
    J Mass Spectrom; 2008 Dec; 43(12):1649-58. PubMed ID: 18613259
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rapid identification of comigrating gel-isolated proteins by ion trap-mass spectrometry.
    Arnott D; Henzel WJ; Stults JT
    Electrophoresis; 1998 May; 19(6):968-80. PubMed ID: 9638943
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Separation of peptide isomers and conformers by ultra performance liquid chromatography.
    Winter D; Pipkorn R; Lehmann WD
    J Sep Sci; 2009 Apr; 32(8):1111-9. PubMed ID: 19360781
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Identification of phosphorylated proteins from thrombin-activated human platelets isolated by two-dimensional gel electrophoresis by electrospray ionization-tandem mass spectrometry (ESI-MS/MS) and liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS).
    Immler D; Gremm D; Kirsch D; Spengler B; Presek P; Meyer HE
    Electrophoresis; 1998 May; 19(6):1015-23. PubMed ID: 9638948
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and application of a phosphoproteomic method using electrostatic repulsion-hydrophilic interaction chromatography (ERLIC), IMAC, and LC-MS/MS analysis to study Marek's Disease Virus infection.
    Chien KY; Liu HC; Goshe MB
    J Proteome Res; 2011 Sep; 10(9):4041-53. PubMed ID: 21736374
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Systematic LC-MS analysis of labile post-translational modifications in complex mixtures.
    Carapito C; Klemm C; Aebersold R; Domon B
    J Proteome Res; 2009 May; 8(5):2608-14. PubMed ID: 19284785
    [TBL] [Abstract][Full Text] [Related]  

  • 16. PhosTShunter: a fast and reliable tool to detect phosphorylated peptides in liquid chromatography Fourier transform tandem mass spectrometry data sets.
    Köcher T; Savitski MM; Nielsen ML; Zubarev RA
    J Proteome Res; 2006 Mar; 5(3):659-68. PubMed ID: 16512682
    [TBL] [Abstract][Full Text] [Related]  

  • 17. VEMS 3.0: algorithms and computational tools for tandem mass spectrometry based identification of post-translational modifications in proteins.
    Matthiesen R; Trelle MB; Højrup P; Bunkenborg J; Jensen ON
    J Proteome Res; 2005; 4(6):2338-47. PubMed ID: 16335983
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Increased throughput for low-abundance protein biomarker verification by liquid chromatography/tandem mass spectrometry.
    Berna M; Ackermann B
    Anal Chem; 2009 May; 81(10):3950-6. PubMed ID: 19388669
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A strategy for identification and quantitation of phosphopeptides by liquid chromatography/tandem mass spectrometry.
    Tsay YG; Wang YH; Chiu CM; Shen BJ; Lee SC
    Anal Biochem; 2000 Dec; 287(1):55-64. PubMed ID: 11078583
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Peptides quantification by liquid chromatography with matrix-assisted laser desorption/ionization and selected reaction monitoring detection.
    Lesur A; Varesio E; Domon B; Hopfgartner G
    J Proteome Res; 2012 Oct; 11(10):4972-82. PubMed ID: 22897511
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.