BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 26389986)

  • 1. Evaluation of the Morphological Characteristics of Laser-Irradiated Dentin.
    Cvikl B; Lilaj B; Franz A; Degendorfer D; Moritz A
    Photomed Laser Surg; 2015 Oct; 33(10):504-8. PubMed ID: 26389986
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Occluding effect of Nd:YAG laser and different dentin desensitizing agents on human dentinal tubules in vitro: a scanning electron microscopy investigation.
    Al-Saud LM; Al-Nahedh HN
    Oper Dent; 2012; 37(4):340-55. PubMed ID: 22313266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of Water-Cooled Nd:YAG Laser on Dentinal Tubule Occlusion In Vitro.
    Xiao S; Liang K; Liu H; Zhang M; Yang H; Guo S; Ding Y
    Photomed Laser Surg; 2017 Feb; 35(2):98-104. PubMed ID: 27827556
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of Er:YAG and CO2 lasers with and without sodium fluoride gel on dentinal tubules: a scanning electron microscope examination.
    Cakar G; Kuru B; Ipci SD; Aksoy ZM; Okar I; Yilmaz S
    Photomed Laser Surg; 2008 Dec; 26(6):565-71. PubMed ID: 19099386
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bond strengths of one-step self-etch adhesives to laser-irradiated and bur-cut dentin after water storage and thermocycling.
    Akin GE; Herguner-Siso S; Ozcan M; Ozel-Bektas O; Akin H
    Photomed Laser Surg; 2012 Apr; 30(4):214-21. PubMed ID: 22420776
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bond strength of adhesive systems to Er,Cr:YSGG laser-irradiated dentin.
    Carvalho AO; Reis AF; de Oliveira MT; de Freitas PC; Aranha AC; Eduardo Cde P; Giannini M
    Photomed Laser Surg; 2011 Nov; 29(11):747-52. PubMed ID: 21923283
    [TBL] [Abstract][Full Text] [Related]  

  • 7. SEM analysis of dentin treated with the Er:YAG laser: a pilot study of the consequences resulting from laser use on adhesion mechanisms.
    Giachetti L; Scaminaci Russo D; Scarpelli F; Vitale M
    J Clin Laser Med Surg; 2004 Feb; 22(1):35-41. PubMed ID: 15117485
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of Er:YAG laser for cavity preparation: an SEM evaluation.
    Freitas PM; Navarro RS; Barros JA; de Paula Eduardo C
    Microsc Res Tech; 2007 Sep; 70(9):803-8. PubMed ID: 17576132
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of different desensitizers and lasers on dentine tubules: An in-vitro analysis.
    Öncü E; Karabekiroğlu S; Ünlü N
    Microsc Res Tech; 2017 Jul; 80(7):737-744. PubMed ID: 28251725
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sealing depth of Nd:YAG laser on human dentinal tubules.
    Liu HC; Lin CP; Lan WH
    J Endod; 1997 Nov; 23(11):691-3. PubMed ID: 9587310
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An evaluation of the occluding effects of Er;Cr:YSGG, Nd:YAG, CO₂ and diode lasers on dentinal tubules: a scanning electron microscope in vitro study.
    Gholami GA; Fekrazad R; Esmaiel-Nejad A; Kalhori KA
    Photomed Laser Surg; 2011 Feb; 29(2):115-21. PubMed ID: 21288081
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Shear bond strength of two adhesive systems bonded to Er:YAG laser-prepared dentin.
    da Silva MP; Barceleiro MO; Dias KR; Zanin F
    Gen Dent; 2011; 59(3):e96-100. PubMed ID: 21903536
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tensile bond strength of Er,Cr:YSGG laser-irradiated human dentin and analysis of dentin-resin interface.
    Lee BS; Lin PY; Chen MH; Hsieh TT; Lin CP; Lai JY; Lan WH
    Dent Mater; 2007 May; 23(5):570-8. PubMed ID: 16820200
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Scanning electron microscopic evaluation of resin-dentin interface after Er:YAG laser preparation.
    Bertrand MF; Hessleyer D; Muller-Bolla M; Nammour S; Rocca JP
    Lasers Surg Med; 2004; 35(1):51-7. PubMed ID: 15278928
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of Er:YAG and Nd:YAG lasers on dentin permeability in root surfaces: a preliminary in vitro study.
    Aranha AC; Domingues FB; Franco VO; Gutknecht N; Eduardo Cde P
    Photomed Laser Surg; 2005 Oct; 23(5):504-8. PubMed ID: 16262582
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of Er:YAG laser on bond strength of self-etching adhesives to caries-affected dentin.
    Koyuturk AE; Ozmen B; Cortcu M; Tokay U; Tosun G; Erhan Sari M
    Microsc Res Tech; 2014 Apr; 77(4):282-8. PubMed ID: 24481952
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Resin bond strength and micromorphology of human teeth prepared with an Erbium:YAG laser.
    Trajtenberg CP; Pereira PN; Powers JM
    Am J Dent; 2004 Oct; 17(5):331-6. PubMed ID: 15575443
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Combined Effects of Glutaraldehyde-based Desensitizer and Nd: YAG Laser on Dentinal Tubules Occlusion.
    Alzarooni AH; El-Damanhoury HM; Aravind SS; Rahman B
    J Contemp Dent Pract; 2024 Jan; 25(1):52-57. PubMed ID: 38514431
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Scanning electron microscopic evaluation of enamel and dentin surfaces after Er:YAG laser preparation and laser conditioning.
    Delmé KI; De Moor RJ
    Photomed Laser Surg; 2007 Oct; 25(5):393-401. PubMed ID: 17975952
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Morphological analysis of the resin-dentin interface in cavities prepared with Er,Cr:YSGG laser or bur in primary teeth.
    Oznurhan F; Olmez A
    Photomed Laser Surg; 2013 Aug; 31(8):386-91. PubMed ID: 23859751
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.