BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 26390093)

  • 1. Subnormothermic ex vivo liver perfusion is a safe alternative to cold static storage for preserving standard criteria grafts.
    Spetzler VN; Goldaracena N; Echiverri J; Kaths JM; Louis KS; Adeyi OA; Yip PM; Grant DR; Selzner N; Selzner M
    Liver Transpl; 2016 Jan; 22(1):111-9. PubMed ID: 26390093
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Subnormothermic ex vivo liver perfusion reduces endothelial cell and bile duct injury after donation after cardiac death pig liver transplantation.
    Knaak JM; Spetzler VN; Goldaracena N; Boehnert MU; Bazerbachi F; Louis KS; Adeyi OA; Minkovich L; Yip PM; Keshavjee S; Levy GA; Grant DR; Selzner N; Selzner M
    Liver Transpl; 2014 Nov; 20(11):1296-305. PubMed ID: 25179693
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anti-inflammatory signaling during ex vivo liver perfusion improves the preservation of pig liver grafts before transplantation.
    Goldaracena N; Echeverri J; Spetzler VN; Kaths JM; Barbas AS; Louis KS; Adeyi OA; Grant DR; Selzner N; Selzner M
    Liver Transpl; 2016 Nov; 22(11):1573-1583. PubMed ID: 27556578
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Normothermic ex vivo liver perfusion using steen solution as perfusate for human liver transplantation: First North American results.
    Selzner M; Goldaracena N; Echeverri J; Kaths JM; Linares I; Selzner N; Serrick C; Marquez M; Sapisochin G; Renner EL; Bhat M; McGilvray ID; Lilly L; Greig PD; Tsien C; Cattral MS; Ghanekar A; Grant DR
    Liver Transpl; 2016 Nov; 22(11):1501-1508. PubMed ID: 27339754
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of Temperature on Porcine Liver Machine Perfusion From Donors After Cardiac Death.
    Nassar A; Liu Q; Farias K; Buccini L; Baldwin W; Bennett A; Mangino M; Irefin S; Cywinski J; Okamoto T; Diago Uso T; Iuppa G; Soliman B; Miller C; Quintini C
    Artif Organs; 2016 Oct; 40(10):999-1008. PubMed ID: 27086771
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of a Rat Liver Machine Perfusion System for Normothermic and Subnormothermic Conditions.
    Nösser M; Gassner JMGV; Moosburner S; Wyrwal D; Claussen F; Hillebrandt KH; Horner R; Tang P; Reutzel-Selke A; Polenz D; Arsenic R; Pratschke J; Sauer IM; Raschzok N
    Tissue Eng Part A; 2020 Jan; 26(1-2):57-65. PubMed ID: 31364485
    [No Abstract]   [Full Text] [Related]  

  • 7. The Effects of Short-term Subnormothermic Perfusion After Cold Preservation on Liver Grafts From Donors After Circulatory Death: An Ex Vivo Rat Model.
    Kakizaki Y; Miyagi S; Shimizu K; Miyazawa K; Nakanishi W; Tokodai K; Hara Y; Nakanishi C; Unno M; Kamei T; Goto M; Satomi S
    Transplantation; 2018 Apr; 102(4):e147-e154. PubMed ID: 29309377
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Eight-Hour Continuous Normothermic Ex Vivo Kidney Perfusion Is a Safe Preservation Technique for Kidney Transplantation: A New Opportunity for the Storage, Assessment, and Repair of Kidney Grafts.
    Kaths JM; Echeverri J; Goldaracena N; Louis KS; Chun YM; Linares I; Wiebe A; Foltys DB; Yip PM; John R; Mucsi I; Ghanekar A; Bagli DJ; Grant DR; Robinson LA; Selzner M
    Transplantation; 2016 Sep; 100(9):1862-70. PubMed ID: 27479157
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dual versus single vessel normothermic ex vivo perfusion of rat liver grafts using metamizole for vasodilatation.
    Claussen F; Gassner JMGV; Moosburner S; Wyrwal D; Nösser M; Tang P; Wegener L; Pohl J; Reutzel-Selke A; Arsenic R; Pratschke J; Sauer IM; Raschzok N
    PLoS One; 2020; 15(7):e0235635. PubMed ID: 32614897
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Subnormothermic machine perfusion for non-heart-beating donor liver grafts preservation in a Swine model: a new strategy to increase the donor pool?
    Gringeri E; Bonsignore P; Bassi D; D'Amico FE; Mescoli C; Polacco M; Buggio M; Luisetto R; Boetto R; Noaro G; Ferrigno A; Boncompagni E; Freitas I; Vairetti MP; Carraro A; Neri D; Cillo U
    Transplant Proc; 2012 Sep; 44(7):2026-8. PubMed ID: 22974898
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Normothermic acellular ex vivo liver perfusion reduces liver and bile duct injury of pig livers retrieved after cardiac death.
    Boehnert MU; Yeung JC; Bazerbachi F; Knaak JM; Selzner N; McGilvray ID; Rotstein OD; Adeyi OA; Kandel SM; Rogalla P; Yip PM; Levy GA; Keshavjee S; Grant DR; Selzner M
    Am J Transplant; 2013 Jun; 13(6):1441-9. PubMed ID: 23668775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combined liver-kidney perfusion enhances protective effects of normothermic perfusion on liver grafts from donation after cardiac death.
    He X; Ji F; Zhang Z; Tang Y; Yang L; Huang S; Li W; Su Q; Xiong W; Zhu Z; Wang L; Lv L; Yao J; Zhang L; Zhang L; Guo Z
    Liver Transpl; 2018 Jan; 24(1):67-79. PubMed ID: 29024427
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hypothermic machine perfusion of the liver: is it more complex than for the kidney?
    Monbaliu D; Heedfeld V; Liu Q; Wylin T; van Pelt J; Vekemans K; Pirenne J
    Transplant Proc; 2011 Nov; 43(9):3445-50. PubMed ID: 22099817
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of Subnormothermic Perfusion Before Transplantation for Liver Grafts from Donation After Cardiac Death: A Simplified Dripping Perfusion Method in Pigs.
    Kakizaki Y; Miyagi S; Shimizu K; Kumata H; Matsumura M; Miyazaki Y; Fukuoka K; Uematsu SS; Tokodai K; Hara Y; Nakanishi C; Unno M; Kamei T; Goto M
    Transplant Proc; 2018 Jun; 50(5):1538-1543. PubMed ID: 29705279
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Functional recovery of donation after cardiac death liver graft by continuous machine perfusion preservation in pigs.
    Shigeta T; Matsuno N; Obara H; Mizunuma H; Kanazawa H; Tanaka H; Fukuda A; Sakamoto S; Kasahara M; Uemoto S; Enosawa S
    Transplant Proc; 2012 May; 44(4):946-7. PubMed ID: 22564592
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hypothermic oxygenated machine perfusion in porcine donation after circulatory determination of death liver transplant.
    Fondevila C; Hessheimer AJ; Maathuis MH; Muñoz J; Taurá P; Calatayud D; Leuvenink H; Rimola A; García-Valdecasas JC; Ploeg RJ
    Transplantation; 2012 Jul; 94(1):22-9. PubMed ID: 22691959
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preservation of steatotic livers: a comparison between cold storage and machine perfusion preservation.
    Bessems M; Doorschodt BM; Kolkert JL; Vetelainen RL; van Vliet AK; Vreeling H; van Marle J; van Gulik TM
    Liver Transpl; 2007 Apr; 13(4):497-504. PubMed ID: 17394146
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preservation of porcine non-heart-beating donor livers by sequential cold storage and warm perfusion.
    Reddy SP; Bhattacharjya S; Maniakin N; Greenwood J; Guerreiro D; Hughes D; Imber CJ; Pigott DW; Fuggle S; Taylor R; Friend PJ
    Transplantation; 2004 May; 77(9):1328-32. PubMed ID: 15167586
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of venous systemic oxygen persufflation supplemented with nitric oxide gas on cold-stored, warm ischemia-damaged experimental liver grafts.
    Srinivasan PK; Yagi S; Doorschodt B; Nagai K; Afify M; Uemoto S; Tolba R
    Liver Transpl; 2012 Feb; 18(2):219-25. PubMed ID: 21987402
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Subnormothermic machine perfusion protects against rat liver preservation injury: a comparative evaluation with conventional cold storage.
    Vairetti M; Ferrigno A; Rizzo V; Richelmi P; Boncompagni E; Neri D; Freitas I; Cillo U
    Transplant Proc; 2007; 39(6):1765-7. PubMed ID: 17692606
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.