These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 2639224)

  • 41. [Scleral buckling using silicone sponge in children and adolescents].
    Koraszewska-Matuszewska B; Formińska M; Klepacki R
    Klin Oczna; 1984 Jul; 86(7):317-9. PubMed ID: 6392714
    [No Abstract]   [Full Text] [Related]  

  • 42. [Miragel in surgery of retinal detachment].
    Kmera-Muszyńska M; Kecik T; Okuniewska-Kalicka M
    Klin Oczna; 1993; 95(9-10):363-5. PubMed ID: 8022171
    [TBL] [Abstract][Full Text] [Related]  

  • 43. [Surgery of retinal detachment (author's transl)].
    Gailloud C; Gonvers M
    Klin Oczna; 1981; 83(4-5):229-30. PubMed ID: 7311377
    [No Abstract]   [Full Text] [Related]  

  • 44. [The scleral buckling combined with argon laser photocoagulation for retinal detachment].
    Li Z; Xia Y; Yang Z; Yang X; Wang X
    Zhonghua Yan Ke Za Zhi; 2001 Jul; 37(4):278-80. PubMed ID: 11864437
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Some materials used as episcleral implants. 3. Histological examination].
    Szwarcowa C; Kaluzny J; Szczypiński J
    Klin Oczna; 1976 Nov; 46(11):1189-91. PubMed ID: 994419
    [No Abstract]   [Full Text] [Related]  

  • 46. [Some materials used as episcleral implants. I. Clinical observations].
    Kaluzny J; Szczypiński J; Szwarcowa C
    Klin Oczna; 1976 Nov; 46(11):1177-82. PubMed ID: 994417
    [No Abstract]   [Full Text] [Related]  

  • 47. Variation of technique of episcleral sponge placement: effect on scleral indentation for retinal detachment repair.
    Boldrey EE
    Ann Ophthalmol; 1981 Jun; 13(6):743-6. PubMed ID: 7020553
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Conventional methods in retinal detachment surgery].
    Starzycka M; Górniak-Bednarz A; Ortyl E; Starzycka-Bigaj E
    Klin Oczna; 1996 Mar; 98(3):225-8. PubMed ID: 9019595
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Experimental studies of reaction of the eyeball to alloplastic implants in surgical treatment of retinal detachment. I. Introduction, scope of work and materials].
    Koziorowska M
    Klin Oczna; 1985 Apr; 87(4):173-5. PubMed ID: 4046479
    [No Abstract]   [Full Text] [Related]  

  • 50. [Evaluation of surgical methods of treatment for retinal detachment].
    Sempińska-Szewczyk J; Swietliczko I; Nawrocki J
    Klin Oczna; 1993 Jun; 95(6):233-5. PubMed ID: 8309194
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Analysis of treatment results in retinal detachment 1976-1982].
    Andrzejewska W; Karczewiczowa D; Anczykowska E; Lisicka E; Stankiewiczowa W
    Klin Oczna; 1984 Feb; 86(2):73-5. PubMed ID: 6374268
    [No Abstract]   [Full Text] [Related]  

  • 52. [Surgical treatment of idiopathic retinal detachment by temporary balloon scleral buckling].
    Walther A; Klein S
    Klin Oczna; 1985 Feb; 87(2):71-2. PubMed ID: 4032974
    [No Abstract]   [Full Text] [Related]  

  • 53. [Experimental studies of using highly fluorinated alkane in the surgical treatment of retinal detachment].
    Toczołowski J; Gerkowicz M; Dmowski W
    Klin Oczna; 1991; 93(4-5):105-7. PubMed ID: 1921213
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Mo-dified scleral buckling for additional fixation of the retina with endovitreal magnetic implant (experimental study)].
    Kazimirova EG; Shiryaev VV; Lyskin PV; Kramarenko EY
    Vestn Oftalmol; 2017; 133(5):24-31. PubMed ID: 29165409
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Synthetic implants in ablatio surgery. Physical properties of materials for cerclage operations].
    Meyer-Schwickerath G; Schmitz-Valckenberg P
    Ber Zusammenkunft Dtsch Ophthalmol Ges; 1978; (75):245-7. PubMed ID: 743102
    [No Abstract]   [Full Text] [Related]  

  • 56. [On the causes of extrusion of episcleral silicone implants following retinal detachment surgery].
    Fu SJ
    Zhonghua Yan Ke Za Zhi; 1985 Jan; 21(1):44-5. PubMed ID: 3920030
    [No Abstract]   [Full Text] [Related]  

  • 57. An evidence-based analysis of surgical interventions for uncomplicated rhegmatogenous retinal detachment.
    Saw SM; Gazzard G; Wagle AM; Lim J; Au Eong KG
    Acta Ophthalmol Scand; 2006 Oct; 84(5):606-12. PubMed ID: 16965489
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [The surgical treatment of retinal detachment by temporary balloon buckling: the late results, reasons for inefficacy and indications].
    Il'nitskiĭ VV; Saksonova EO; Movshovich AI
    Vestn Oftalmol; 1994; 110(2):11-4. PubMed ID: 8073569
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [Experience with the treatment of detachment of the retina by circular buckling of the sclera using a thread with silicone beads].
    Vodovozov AM; Fares A
    Oftalmol Zh; 1988; (1):34-7. PubMed ID: 3387001
    [No Abstract]   [Full Text] [Related]  

  • 60. [Complications of intra- and extrascleral silicone implants].
    Stankiewicz A; Smolińska K; Rudobielska I
    Klin Oczna; 1984 Dec; 86(12):553-4. PubMed ID: 6536796
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.