These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 26394338)

  • 1. Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study.
    Bilhan H; Bilmenoglu C; Urgun AC; Ates G; Bural C; Cilingir A; Geckili O
    Int J Oral Maxillofac Implants; 2015; 30(5):1036-40. PubMed ID: 26394338
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of implant geometry on primary insertion stability and simulated peri-implant bone loss: an in vitro study using resonance frequency analysis and damping capacity assessment.
    Lachmann S; Laval JY; Axmann D; Weber H
    Int J Oral Maxillofac Implants; 2011; 26(2):347-55. PubMed ID: 21483888
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis.
    Falco A; Berardini M; Trisi P
    Int J Oral Maxillofac Implants; 2018; 33(4):824-830. PubMed ID: 30024998
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone.
    Bilhan H; Geckili O; Mumcu E; Bozdag E; Sünbüloğlu E; Kutay O
    J Oral Rehabil; 2010 Dec; 37(12):900-7. PubMed ID: 20529176
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative ex vivo evaluation of two electronic percussive testing devices measuring the stability of dental implants.
    Geckili O; Bilhan H; Cilingir A; Bilmenoglu C; Ates G; Urgun AC; Bural C
    J Periodontol; 2014 Dec; 85(12):1786-91. PubMed ID: 25269525
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface.
    Barewal RM; Oates TW; Meredith N; Cochran DL
    Int J Oral Maxillofac Implants; 2003; 18(5):641-51. PubMed ID: 14579951
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stability and marginal bone loss with three types of early loaded implants during the first year after loading.
    Liaje A; Ozkan YK; Ozkan Y; Vanlioğlu B
    Int J Oral Maxillofac Implants; 2012; 27(1):162-72. PubMed ID: 22299093
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite, Osseotite, SLA and TiOblast implants.
    Sul YT; Jönsson J; Yoon GS; Johansson C
    Clin Oral Implants Res; 2009 Oct; 20(10):1146-55. PubMed ID: 19719742
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Implant Thread Geometry on Secondary Stability, Bone Density, and Bone-to-Implant Contact: A Biomechanical and Histological Analysis.
    Trisi P; Berardini M; Falco A; Podaliri Vulpiani M
    Implant Dent; 2015 Aug; 24(4):384-91. PubMed ID: 25939083
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A correlation between bone (B), insertion torque (IT), and implant stability (S): BITS score.
    Herekar M; Sethi M; Ahmad T; Fernandes AS; Patil V; Kulkarni H
    J Prosthet Dent; 2014 Oct; 112(4):805-10. PubMed ID: 24726588
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modal analysis for implant stability assessment: Sensitivity of this methodology for different implant designs.
    Zanetti EM; Ciaramella S; Calì M; Pascoletti G; Martorelli M; Asero R; Watts DC
    Dent Mater; 2018 Aug; 34(8):1235-1245. PubMed ID: 29891196
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Influence of Implant Shape on Primary Stability of Implants With a Thread Cutting and Forming Design: An Ex Vivo Study.
    Dayan C; Geckili O; Bural C
    J Oral Implantol; 2019 Jun; 45(3):181-185. PubMed ID: 30702967
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Resonance frequency analysis measurements of implants at placement surgery.
    Ostman PO; Hellman M; Wendelhag I; Sennerby L
    Int J Prosthodont; 2006; 19(1):77-83; discussion 84. PubMed ID: 16479765
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability.
    Lachmann S; Jäger B; Axmann D; Gomez-Roman G; Groten M; Weber H
    Clin Oral Implants Res; 2006 Feb; 17(1):75-9. PubMed ID: 16441787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Parameters of implant stability measurements based on resonance frequency and damping capacity: a comparative finite element analysis.
    Winter W; Möhrle S; Holst S; Karl M
    Int J Oral Maxillofac Implants; 2010; 25(3):532-9. PubMed ID: 20556252
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of the correlation between implant stability and bone density by computed tomography and resonance frequency analysis in fresh cadavers.
    Coutant JC; Seguela V; Hauret L; Caix P; Ella B
    Int J Oral Maxillofac Implants; 2014; 29(6):1264-70. PubMed ID: 25397790
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modal damping factor detected with an impulse-forced vibration method provides additional information on osseointegration during dental implant healing.
    Feng SW; Chang WJ; Lin CT; Lee SY; Teng NC; Huang HM
    Int J Oral Maxillofac Implants; 2015; 30(6):1333-40. PubMed ID: 26574858
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implant stability measurement of delayed and immediately loaded implants during healing.
    Bischof M; Nedir R; Szmukler-Moncler S; Bernard JP; Samson J
    Clin Oral Implants Res; 2004 Oct; 15(5):529-39. PubMed ID: 15355394
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of the Localization of Frontal Bone Defects on Primary Stability Values of 2 Different Implant Designs: An In Vitro Study.
    Mercan U; Bilhan H; Meral DG; Kazokoglu S; Aykol-Sahin G; Geckili O
    Implant Dent; 2017 Feb; 26(1):87-94. PubMed ID: 28079610
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants.
    Çehreli S; Arman-Özçırpıcı A
    Am J Orthod Dentofacial Orthop; 2012 Feb; 141(2):187-95. PubMed ID: 22284286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.