These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
293 related articles for article (PubMed ID: 26398125)
21. In vitro and in vivo evaluation of a new large animal spirometry device using mainstream CO2 flow sensors. Ambrisko TD; Lammer V; Schramel JP; Moens YP Equine Vet J; 2014 Jul; 46(4):507-11. PubMed ID: 23855602 [TBL] [Abstract][Full Text] [Related]
22. A respiratory monitoring device based on clavicular motion. Pitts DG; Patel MK; Lang PO; Sinclair AJ; Aspinall R Physiol Meas; 2013 Aug; 34(8):N51-61. PubMed ID: 23860005 [TBL] [Abstract][Full Text] [Related]
23. Determination of respiratory system mechanics during inspiration and expiration by FLow-controlled EXpiration (FLEX): a pilot study in anesthetized pigs. Schumann S; Goebel U; Haberstroh J; Vimlati L; Schneider M; Lichtwarck-Aschoff M; Guttmann J Minerva Anestesiol; 2014 Jan; 80(1):19-28. PubMed ID: 24193175 [TBL] [Abstract][Full Text] [Related]
24. [A new generation of pulmonary function measuring system]. Zeng BX; Chen SS; Huang M Zhongguo Yi Liao Qi Xie Za Zhi; 2000 Feb; 24(2):86-8. PubMed ID: 12583095 [TBL] [Abstract][Full Text] [Related]
25. Ambulatory monitoring of respiration: inhibitory breathing in the natural environment. Anderson DE; Coyle K; Haythornthwaite JA Psychophysiology; 1992 Sep; 29(5):551-7. PubMed ID: 1410184 [TBL] [Abstract][Full Text] [Related]
26. Hemodynamic and respiratory changes during lung recruitment and descending optimal positive end-expiratory pressure titration in patients with acute respiratory distress syndrome. Toth I; Leiner T; Mikor A; Szakmany T; Bogar L; Molnar Z Crit Care Med; 2007 Mar; 35(3):787-93. PubMed ID: 17255855 [TBL] [Abstract][Full Text] [Related]
27. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique. Battista L; Sciuto SA; Scorza A Rev Sci Instrum; 2013 Mar; 84(3):035005. PubMed ID: 23556844 [TBL] [Abstract][Full Text] [Related]
28. AANA journal course: new technologies in anesthesia: update for nurse anesthetists--monitoring ventilation and compliance with Side Stream Spirometry. Huffman LM AANA J; 1991 Jun; 59(3):249-59. PubMed ID: 1950403 [TBL] [Abstract][Full Text] [Related]
29. Photoplethysmogram measurement without direct skin-to-sensor contact using an adaptive light source intensity control. Baek HJ; Chung GS; Kim KK; Kim JS; Park KS IEEE Trans Inf Technol Biomed; 2009 Nov; 13(6):1085-8. PubMed ID: 19775979 [TBL] [Abstract][Full Text] [Related]
30. Non-invasive measurement of total respiratory compliance and resistance in cats. Epstein A; Godfrey S; Bar-Yishay E; Putilov A; Bark H Respir Physiol Neurobiol; 2007 May; 156(2):179-86. PubMed ID: 17113363 [TBL] [Abstract][Full Text] [Related]
31. Non-contact measurement of respiratory function and deduction of tidal volume. Lee YS; Pathirana PN; Steinfort CL; Caelli T Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():594-7. PubMed ID: 25570029 [TBL] [Abstract][Full Text] [Related]
32. Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses. Schmalisch G; Schmidt M; Proquitté H; Foitzik B; Rüdiger M; Wauer RR Crit Care Med; 2003 May; 31(5):1435-41. PubMed ID: 12771615 [TBL] [Abstract][Full Text] [Related]
33. Changes in lung volume and upper airway using MRI during application of nasal expiratory positive airway pressure in patients with sleep-disordered breathing. Braga CW; Chen Q; Burschtin OE; Rapoport DM; Ayappa I J Appl Physiol (1985); 2011 Nov; 111(5):1400-9. PubMed ID: 21799124 [TBL] [Abstract][Full Text] [Related]
34. Validation of the thoracic impedance derived respiratory signal using multilevel analysis. Houtveen JH; Groot PF; de Geus EJ Int J Psychophysiol; 2006 Feb; 59(2):97-106. PubMed ID: 15893397 [TBL] [Abstract][Full Text] [Related]
35. Extraction and Analysis of Respiratory Motion Using a Comprehensive Wearable Health Monitoring System. George UZ; Moon KS; Lee SQ Sensors (Basel); 2021 Feb; 21(4):. PubMed ID: 33671202 [TBL] [Abstract][Full Text] [Related]
36. The Structure Design of Piezoelectric Poly(vinylidene Fluoride) (PVDF) Polymer-Based Sensor Patch for the Respiration Monitoring under Dynamic Walking Conditions. Lei KF; Hsieh YZ; Chiu YY; Wu MH Sensors (Basel); 2015 Jul; 15(8):18801-12. PubMed ID: 26263992 [TBL] [Abstract][Full Text] [Related]