These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 26410097)

  • 1. Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation.
    Zhu M; Chen JY; Chong HC; Yew AKS; Foo LSS; Chia SL; Lo NN; Yeo SJ
    Knee Surg Sports Traumatol Arthrosc; 2017 Aug; 25(8):2567-2572. PubMed ID: 26410097
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.
    Anderl W; Pauzenberger L; Kölblinger R; Kiesselbach G; Brandl G; Laky B; Kriegleder B; Heuberer P; Schwameis E
    Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):102-11. PubMed ID: 25326759
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty.
    Gong S; Xu W; Wang R; Wang Z; Wang B; Han L; Chen G
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1083-1095. PubMed ID: 30377714
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Patient-Specific Instrumentation Does Not Affect Rotational Alignment of the Femoral Component and Perioperative Blood Loss in Total Knee Arthroplasty: A Prospective, Randomized, Controlled Trial.
    Randelli PS; Menon A; Pasqualotto S; Zanini B; Compagnoni R; Cucchi D
    J Arthroplasty; 2019 Jul; 34(7):1374-1381.e1. PubMed ID: 30979672
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Patient-specific instrumentation development in TKA: 1st and 2nd generation designs in comparison with conventional instrumentation.
    Kwon OR; Kang KT; Son J; Suh DS; Heo DB; Koh YG
    Arch Orthop Trauma Surg; 2017 Jan; 137(1):111-118. PubMed ID: 28005167
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The John Insall Award: No Functional Benefit After Unicompartmental Knee Arthroplasty Performed With Patient-specific Instrumentation: A Randomized Trial.
    Ollivier M; Parratte S; Lunebourg A; Viehweger E; Argenson JN
    Clin Orthop Relat Res; 2016 Jan; 474(1):60-8. PubMed ID: 25791446
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty.
    Huijbregts HJ; Khan RJ; Sorensen E; Fick DP; Haebich S
    Acta Orthop; 2016 Aug; 87(4):386-94. PubMed ID: 27249110
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial.
    Kosse NM; Heesterbeek PJC; Schimmel JJP; van Hellemondt GG; Wymenga AB; Defoort KC
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1792-1799. PubMed ID: 29181560
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study.
    Yaffe M; Luo M; Goyal N; Chan P; Patel A; Cayo M; Stulberg SD
    Int J Comput Assist Radiol Surg; 2014 Sep; 9(5):837-44. PubMed ID: 24337791
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Patient-specific instrumentation in total knee arthroplasty: simpler, faster and more accurate than standard instrumentation-a randomized controlled trial.
    Vide J; Freitas TP; Ramos A; Cruz H; Sousa JP
    Knee Surg Sports Traumatol Arthrosc; 2017 Aug; 25(8):2616-2621. PubMed ID: 26585908
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Use of Patient Specific Instruments at Total Knee Arthroplasty. One-Year Results of a Prospective Randomised Study].
    Musil D; Stehlík J; Abrman K; Held M; Sadovský P
    Acta Chir Orthop Traumatol Cech; 2016; 83(3):175-81. PubMed ID: 27484075
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can a Single-Use and Patient-Specific Instrumentation Be Reliably Used in Primary Total Knee Arthroplasty? A Multicenter Controlled Study.
    Abane L; Zaoui A; Anract P; Lefevre N; Herman S; Hamadouche M
    J Arthroplasty; 2018 Jul; 33(7):2111-2118. PubMed ID: 29576488
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation.
    Schotanus MGM; Thijs E; Boonen B; Kerens B; Jong B; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1656-1661. PubMed ID: 28785788
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Systematic review of patient-specific instrumentation in total knee arthroplasty: new but not improved.
    Sassoon A; Nam D; Nunley R; Barrack R
    Clin Orthop Relat Res; 2015 Jan; 473(1):151-8. PubMed ID: 25059850
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The accuracy of component alignment in custom cutting blocks compared with conventional total knee arthroplasty instrumentation: prospective control trial.
    Chotanaphuti T; Wangwittayakul V; Khuangsirikul S; Foojareonyos T
    Knee; 2014 Jan; 21(1):185-8. PubMed ID: 23999209
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty.
    Chan WC; Pinder E; Loeffler M
    J Orthop Surg (Hong Kong); 2016 Aug; 24(2):175-8. PubMed ID: 27574258
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Implant positioning in TKA: comparison between conventional and patient-specific instrumentation.
    Ferrara F; Cipriani A; Magarelli N; Rapisarda S; De Santis V; Burrofato A; Leone A; Bonomo L
    Orthopedics; 2015 Apr; 38(4):e271-80. PubMed ID: 25901619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis.
    Kizaki K; Shanmugaraj A; Yamashita F; Simunovic N; Duong A; Khanna V; Ayeni OR
    BMC Musculoskelet Disord; 2019 Nov; 20(1):561. PubMed ID: 31759392
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Patient-specific instrumentation does not improve alignment in total knee arthroplasty.
    Russell R; Brown T; Huo M; Jones R
    J Knee Surg; 2014 Dec; 27(6):501-4. PubMed ID: 24504637
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Abnormal rate of intraoperative and postoperative implant positioning outliers using "MRI-based patient-specific" compared to "computer assisted" instrumentation in total knee replacement.
    Ollivier M; Tribot-Laspiere Q; Amzallag J; Boisrenoult P; Pujol N; Beaufils P
    Knee Surg Sports Traumatol Arthrosc; 2016 Nov; 24(11):3441-3447. PubMed ID: 25994474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.