267 related articles for article (PubMed ID: 26411812)
1. A Pilot Assessment of Carotid and Brachial Artery Blood Flow Estimation Using Ultrasound Doppler in Cardiac Surgery Patients.
Weber U; Glassford NJ; Eastwood GM; Bellomo R; Hilton AK
J Cardiothorac Vasc Anesth; 2016 Jan; 30(1):141-8. PubMed ID: 26411812
[TBL] [Abstract][Full Text] [Related]
2. A pilot study of the relationship between Doppler-estimated carotid and brachial artery flow and cardiac index.
Weber U; Glassford NJ; Eastwood GM; Bellomo R; Hilton AK
Anaesthesia; 2015 Oct; 70(10):1140-7. PubMed ID: 26010229
[TBL] [Abstract][Full Text] [Related]
3. How arterial stiffness may affect coronary blood flow: a challenging pathophysiological link.
Cusmà-Piccione M; Zito C; Khandheria BK; Pizzino F; Di Bella G; Antonini-Canterin F; Vriz O; Bello VA; Zimbalatti C; La Carrubba S; Oreto G; Carerj S
J Cardiovasc Med (Hagerstown); 2014 Nov; 15(11):797-802. PubMed ID: 25251941
[TBL] [Abstract][Full Text] [Related]
4. Carotid Doppler blood flow measurement during cardiopulmonary resuscitation is feasible: A first in man study.
Adedipe AA; Fly DL; Schwitz SD; Jorgenson DB; Duric H; Sayre MR; Nichol G
Resuscitation; 2015 Nov; 96():121-5. PubMed ID: 26234896
[TBL] [Abstract][Full Text] [Related]
5. Non-invasive assessment of arterial stiffness by pulse-wave velocity correlates with endothelial dysfunction.
Jadhav UM; Kadam NN
Indian Heart J; 2005; 57(3):226-32. PubMed ID: 16196179
[TBL] [Abstract][Full Text] [Related]
6. Doppler cardiac output and left ventricular performance after cardiac surgery. Pulsed Doppler ascending aorta and pulmonary blood flows and left ventricular function using implanted microprobes.
Fratacci MD; Payen D; Beloucif S; Laborde F
Chest; 1992 Aug; 102(2):380-6. PubMed ID: 1643918
[TBL] [Abstract][Full Text] [Related]
7. Correlation of Carotid Doppler Blood Flow With Invasive Cardiac Output Measurements in Cardiac Surgery Patients.
van Houte J; Mooi FJ; Montenij LJ; Meijs LPB; Suriani I; Conjaerts BCM; Houterman S; Bouwman AR
J Cardiothorac Vasc Anesth; 2022 Apr; 36(4):1081-1091. PubMed ID: 34756675
[TBL] [Abstract][Full Text] [Related]
8. Bilateral brachial artery occlusion decreases internal carotid artery volume flow: a simple adjunct for cerebral protection?
Kashyap VS; Franklin KS; Fitzpatrick CM
J Endovasc Ther; 2005 Aug; 12(4):454-60. PubMed ID: 16048377
[TBL] [Abstract][Full Text] [Related]
9. Reduced flow velocity in the internal carotid artery independently of cardiac hemodynamics in patients with cerebral ischemia.
Fukuhara T; Hida K; Manabe Y; Munemasa M; Matsubara H; Akao I; Namba Y; Kuyama H
J Clin Ultrasound; 2007; 35(6):314-21. PubMed ID: 17427213
[TBL] [Abstract][Full Text] [Related]
10. Rapid ultrasound score as an indicator of atherosclerosis' clinical manifestations in a population of hypertensives: the interrelationship between flow-mediated dilatation of brachial artery, carotid intima thickness, renal resistive index and retina resistive index of central artery.
Natale F; Ranieri A; Siciliano A; Casillo B; Di Lorenzo C; Granato C; Cirillo C; Concilio C; Tedesco MA; Calabrò P; Golino P; Russo MG; Calabrò R
Anadolu Kardiyol Derg; 2014 Feb; 14(1):9-15. PubMed ID: 24342928
[TBL] [Abstract][Full Text] [Related]
11. Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device.
Jaeggi P; Hofer CK; Klaghofer R; Fodor P; Genoni M; Zollinger A
J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):217-20. PubMed ID: 12698405
[TBL] [Abstract][Full Text] [Related]
12. Measuring peripheral resistance and conduit arterial structure in humans using Doppler ultrasound.
Naylor LH; Weisbrod CJ; O'Driscoll G; Green DJ
J Appl Physiol (1985); 2005 Jun; 98(6):2311-5. PubMed ID: 15691903
[TBL] [Abstract][Full Text] [Related]
13. Non-invasive evaluation of the conduit function and the buffering function of large arteries in man.
Demolis PD; Asmar RG; Levy BI; Safar ME
Clin Physiol; 1991 Nov; 11(6):553-64. PubMed ID: 1663017
[TBL] [Abstract][Full Text] [Related]
14. [The effect of gender on vasomotor function of the vascular endothelium and cardiovascular remodelling during aging].
Bojić M; Djurić D; Petrović J; Popović Z; Tasić N; Petrović B; Djurić A; Bojić D; Plećas B; Mitrović V; Kanjuh V
Srp Arh Celok Lek; 1999; 127(3-4):101-8. PubMed ID: 10500433
[TBL] [Abstract][Full Text] [Related]
15. Pulsed Doppler ascending aortic, carotid, brachial, and femoral artery blood flows during caudal anesthesia in infants.
Payen D; Ecoffey C; Carli P; Dubousset AM
Anesthesiology; 1987 Nov; 67(5):681-5. PubMed ID: 3314596
[TBL] [Abstract][Full Text] [Related]
16. Radial artery pulse pressure variation correlates with brachial artery peak velocity variation in ventilated subjects when measured by internal medicine residents using hand-carried ultrasound devices.
Brennan JM; Blair JE; Hampole C; Goonewardena S; Vasaiwala S; Shah D; Spencer KT; Schmidt GA
Chest; 2007 May; 131(5):1301-7. PubMed ID: 17494781
[TBL] [Abstract][Full Text] [Related]
17. In vivo lateral blood flow velocity measurement using speckle size estimation.
Xu T; Hozan M; Bashford GR
Ultrasound Med Biol; 2014 May; 40(5):931-7. PubMed ID: 24462149
[TBL] [Abstract][Full Text] [Related]
18. Estimation of brachial artery volume flow by duplex ultrasound imaging predicts dialysis access maturation.
Ko SH; Bandyk DF; Hodgkiss-Harlow KD; Barleben A; Lane J
J Vasc Surg; 2015 Jun; 61(6):1521-7. PubMed ID: 25769390
[TBL] [Abstract][Full Text] [Related]
19. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.
Lindberg L; Johansson S; Perez-de-Sa V
Pediatr Crit Care Med; 2014 Feb; 15(2):139-47. PubMed ID: 24366506
[TBL] [Abstract][Full Text] [Related]
20. Carotid Doppler flowmetry correlates poorly with thermodilution cardiac output following cardiac surgery.
Roehrig C; Govier M; Robinson J; Aneman A
Acta Anaesthesiol Scand; 2017 Jan; 61(1):31-38. PubMed ID: 27766613
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]