73 related articles for article (PubMed ID: 26416070)
1. Stereotactic body radiation therapy patient specific quality assurance using a two-dimensional array at extended source to surface distance.
Stathakis S; Mavroidis P; Narayanasamy G; Markovic M; Myers P; Papanikolaou N
J BUON; 2015; 20(4):1154-63. PubMed ID: 26416070
[TBL] [Abstract][Full Text] [Related]
2. High resolution ion chamber array delivery quality assurance for robotic radiosurgery: Commissioning and validation.
Blanck O; Masi L; Chan MK; Adamczyk S; Albrecht C; Damme MC; Loutfi-Krauss B; Alraun M; Fehr R; Ramm U; Siebert FA; Stelljes TS; Poppinga D; Poppe B
Phys Med; 2016 Jun; 32(6):838-46. PubMed ID: 27245301
[TBL] [Abstract][Full Text] [Related]
3. Volumetric-modulated arc therapy: effective and efficient end-to-end patient-specific quality assurance.
O'Daniel J; Das S; Wu QJ; Yin FF
Int J Radiat Oncol Biol Phys; 2012 Apr; 82(5):1567-74. PubMed ID: 21470797
[TBL] [Abstract][Full Text] [Related]
4. IMRT quality assurance using a second treatment planning system.
Anjum MN; Parker W; Ruo R; Aldahlawi I; Afzal M
Med Dosim; 2010; 35(4):274-9. PubMed ID: 19944590
[TBL] [Abstract][Full Text] [Related]
5. Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance.
Yewondwossen M
Med Dosim; 2012; 37(3):250-6. PubMed ID: 22189031
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric quality assurance for intensity-modulated radiotherapy feasibility study for a filmless approach.
Wiezorek T; Banz N; Schwedas M; Scheithauer M; Salz H; Georg D; Wendt TG
Strahlenther Onkol; 2005 Jul; 181(7):468-74. PubMed ID: 15995841
[TBL] [Abstract][Full Text] [Related]
7. Comparison of Dosimetric Performance among Commercial Quality Assurance Systems for Verifying Pretreatment Plans of Stereotactic Body Radiotherapy Using Flattening-Filter-Free Beams.
Chung JB; Kang SW; Eom KY; Song C; Choi KS; Suh TS
J Korean Med Sci; 2016 Nov; 31(11):1742-1748. PubMed ID: 27709851
[TBL] [Abstract][Full Text] [Related]
8. Characterization of responses of 2d array seven29 detector and its combined use with octavius phantom for the patient-specific quality assurance in rapidarc treatment delivery.
Syamkumar SA; Padmanabhan S; Sukumar P; Nagarajan V
Med Dosim; 2012; 37(1):53-60. PubMed ID: 21741819
[TBL] [Abstract][Full Text] [Related]
9. A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans.
Li G; Wu K; Peng G; Zhang Y; Bai S
Med Dosim; 2014; 39(4):309-13. PubMed ID: 24958705
[TBL] [Abstract][Full Text] [Related]
10. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance.
Gagnon JC; Thériault D; Guillot M; Archambault L; Beddar S; Gingras L; Beaulieu L
Med Phys; 2012 Jan; 39(1):429-36. PubMed ID: 22225313
[TBL] [Abstract][Full Text] [Related]
11. A method to enhance 2D ion chamber array patient specific quality assurance for IMRT.
Diaz Moreno RM; Venencia D; Garrigo E; Pipman Y
Australas Phys Eng Sci Med; 2017 Mar; 40(1):145-151. PubMed ID: 27873283
[TBL] [Abstract][Full Text] [Related]
12. Characterization of a 2D ion chamber array for the verification of radiotherapy treatments.
Spezi E; Angelini AL; Romani F; Ferri A
Phys Med Biol; 2005 Jul; 50(14):3361-73. PubMed ID: 16177515
[TBL] [Abstract][Full Text] [Related]
13. Three-dimensional gamma criterion for patient-specific quality assurance of spot scanning proton beams.
Chang C; Poole KL; Teran AV; Luckman S; Mah D
J Appl Clin Med Phys; 2015 Sep; 16(5):381–388. PubMed ID: 26699329
[TBL] [Abstract][Full Text] [Related]
14. Quality assurance of rapid arc treatments: performances and pre-clinical verifications of a planar detector (MapCHECK2).
Rinaldin G; Perna L; Agnello G; Pallazzi G; Cattaneo GM; Fiorino C; Calandrino R
Phys Med; 2014 Mar; 30(2):184-90. PubMed ID: 23751395
[TBL] [Abstract][Full Text] [Related]
15. Patient-specific dose quality assurance of single-isocenter multiple brain metastasis stereotactic radiosurgery using PTW Octavius 4D.
McCulloch J; Pawlowski J; Kirby N; Rasmussen K; Shi Z; Myers P; Stathakis S; Papanikolaou N; Saenz DL
J Appl Clin Med Phys; 2020 Sep; 21(9):107-115. PubMed ID: 32681753
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric verification of brain and head and neck intensity-modulated radiation therapy treatment using EDR2 films and 2D ion chamber array matrix.
Varatharaj C; Ravikumar M; Sathiyan S; Supe SS; Vivek TR; Manikandan A
J Cancer Res Ther; 2010; 6(2):179-84. PubMed ID: 20622365
[TBL] [Abstract][Full Text] [Related]
17. Clinical Evaluation of a Two-dimensional Liquid-Filled Ion chamber Detector Array for Verification of High Modulation Small Fields in Radiotherapy.
Markovic M; Narayanasamy G; Stathakis S; Mavroidis P; Jurkovic IA; Saenz D; Papanikolaou N
J Med Phys; 2019; 44(2):91-98. PubMed ID: 31359926
[TBL] [Abstract][Full Text] [Related]
18. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device.
Kavuma A; Glegg M; Metwaly M; Currie G; Elliott A
Phys Med Biol; 2010 Jan; 55(2):435-52. PubMed ID: 20019398
[TBL] [Abstract][Full Text] [Related]
19. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT.
Korevaar EW; Wauben DJ; van der Hulst PC; Langendijk JA; Van't Veld AA
Radiother Oncol; 2011 Sep; 100(3):446-52. PubMed ID: 21963288
[TBL] [Abstract][Full Text] [Related]
20. Statistical variability and confidence intervals for planar dose QA pass rates.
Bailey DW; Nelms BE; Attwood K; Kumaraswamy L; Podgorsak MB
Med Phys; 2011 Nov; 38(11):6053-64. PubMed ID: 22047370
[TBL] [Abstract][Full Text] [Related]