These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 26422962)

  • 21. A simple fibreoptic assisted laryngoscope for paediatric difficult intubation: a manikin study.
    Komiya K; Inagawa G; Nakamura K; Kikuchi T; Fujimoto J; Sugawara Y; Goto T
    Anaesthesia; 2009 Apr; 64(4):425-9. PubMed ID: 19317709
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Successful fiberoptic tracheal intubation via Cobra PLA in a patient with an epiglottic tumor].
    Kusaka Y; Uda R; Son H; Akatsuka M
    Masui; 2009 Apr; 58(4):474-6. PubMed ID: 19364014
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Study and reflection on anesthesia for tracheobronchopathia osteochondroplastica.
    Huang L; Wang J; Chen S; Fang X
    J Int Med Res; 2020 Nov; 48(11):300060520971498. PubMed ID: 33233977
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Video-assisted versus conventional tracheal intubation in morbidly obese patients.
    Dhonneur G; Abdi W; Ndoko SK; Amathieu R; Risk N; El Housseini L; Polliand C; Champault G; Combes X; Tual L
    Obes Surg; 2009 Aug; 19(8):1096-101. PubMed ID: 18836785
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Prospective model-based comparison of different laryngoscopes for difficult intubation in infants.
    Kalbhenn J; Boelke AK; Steinmann D
    Paediatr Anaesth; 2012 Aug; 22(8):776-80. PubMed ID: 22646973
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
    Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
    Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Successful ventilation through a Rüsch intubation guide catheter in severe laryngotracheal stenosis.
    Van Regemorter V; Potié A; Schmitz S; Scholtes JL; Veevaete L; Van Boven M
    J Otolaryngol Head Neck Surg; 2018 May; 47(1):38. PubMed ID: 29801509
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fiberoptic intubation through an I-gel supraglottic airway in two patients with predicted difficult airway and intellectual disability.
    Michalek P; Hodgkinson P; Donaldson W
    Anesth Analg; 2008 May; 106(5):1501-4, table of contents. PubMed ID: 18420867
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Intubation with a double lumen tube in patients with difficult airway using endoscopy mask, and tracheal tube guide].
    Arai K; Kobayashi TL; Kato S; Watanabe K
    Masui; 2001 May; 50(5):516-8. PubMed ID: 11424468
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
    van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
    Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Double-lumen tube tracheal intubation using a rigid video-stylet: a randomized controlled comparison with the Macintosh laryngoscope.
    Yang M; Kim JA; Ahn HJ; Choi JW; Kim DK; Cho EA
    Br J Anaesth; 2013 Dec; 111(6):990-5. PubMed ID: 23975566
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Successful tracheal intubation using the pediatric Airtraq optical laryngoscope in a pediatric patient with Robin sequence].
    Iwai H; Kanai R; Takaku Y; Hirabayashi Y; Seo N
    Masui; 2011 Feb; 60(2):189-91. PubMed ID: 21384653
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Placement of a double-lumen tube using a 6 mm diameter fibro-bronchoscope and a Cook exchange catheter in a patient with unforeseen tracheal intubation difficulty].
    Villalonga A; Metje M; Torres-Bahí S; Aragonès N; Navarro M; March X
    Rev Esp Anestesiol Reanim; 2002 Apr; 49(4):205-8. PubMed ID: 14606381
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A comparison of the GlideScope with the Macintosh laryngoscope for nasotracheal intubation in patients with ankylosing spondylitis.
    Lili X; Zhiyong H; Jianjun S
    J Neurosurg Anesthesiol; 2014 Jan; 26(1):27-31. PubMed ID: 23764717
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Failed tracheal intubation using a laryngoscope and intubating laryngeal mask.
    Asai T; Hirose T; Shingu K
    Can J Anaesth; 2000 Apr; 47(4):325-8. PubMed ID: 10764176
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of fibrescope guided intubation via the classic laryngeal mask airway and i-gel in a manikin.
    de Lloyd L; Hodzovic I; Voisey S; Wilkes AR; Latto IP
    Anaesthesia; 2010 Jan; 65(1):36-43. PubMed ID: 19891671
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Management of difficult pediatric airway].
    Kinouchi K
    Masui; 2006 Jan; 55(1):24-32. PubMed ID: 16440704
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Awake fiberoptic intubation with Parker Flex-Tip tracheal tube in a patient with obesity, goiter, and laryngo-tracheal shift].
    Suzuki M; Mizuno J; Harashima T; Ichinokawa Y; Morita S
    Masui; 2010 Jun; 59(6):731-3. PubMed ID: 20560376
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Fiberoptic tracheal intubation through a laryngeal mask airway in a pediatric patient with treacher collins syndrome].
    Ogata T; Saito T; Tachikawa M; Arai T; Okuda Y
    Masui; 2013 Dec; 62(12):1413-5. PubMed ID: 24498771
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of wire reinforced tubes with warmed standard tubes to facilitate fiberoptic intubation.
    Connelly NR; Kyle R; Gotta J; Calimaran A; Robbins LD; Kanter G; Dunn SM
    J Clin Anesth; 2001 Feb; 13(1):3-5. PubMed ID: 11259886
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.