117 related articles for article (PubMed ID: 26429245)
1. Monte Carlo simulations of the dose from imaging with GE eXplore 120 micro-CT using GATE.
Bretin F; Bahri MA; Luxen A; Phillips C; Plenevaux A; Seret A
Med Phys; 2015 Oct; 42(10):5711-9. PubMed ID: 26429245
[TBL] [Abstract][Full Text] [Related]
2. Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom.
Taschereau R; Chow PL; Chatziioannou AF
Med Phys; 2006 Jan; 33(1):216-24. PubMed ID: 16485428
[TBL] [Abstract][Full Text] [Related]
3. Application of the optically stimulated luminescence (OSL) technique for mouse dosimetry in micro-CT imaging.
Vrigneaud JM; Courteau A; Ranouil J; Morgand L; Raguin O; Walker P; Oudot A; Collin B; Brunotte F
Med Phys; 2013 Dec; 40(12):122102. PubMed ID: 24320529
[TBL] [Abstract][Full Text] [Related]
4. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
[TBL] [Abstract][Full Text] [Related]
5. Monte Carlo evaluation of CTD(infinity) in infinitely long cylinders of water, polyethylene and PMMA with diameters from 10 mm to 500 mm.
Zhou H; Boone JM
Med Phys; 2008 Jun; 35(6):2424-31. PubMed ID: 18649475
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric characterization and organ dose assessment in digital breast tomosynthesis: Measurements and Monte Carlo simulations using voxel phantoms.
Baptista M; Di Maria S; Barros S; Figueira C; Sarmento M; Orvalho L; Vaz P
Med Phys; 2015 Jul; 42(7):3788-800. PubMed ID: 26133581
[TBL] [Abstract][Full Text] [Related]
7. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations.
Gu J; Bednarz B; Caracappa PF; Xu XG
Phys Med Biol; 2009 May; 54(9):2699-717. PubMed ID: 19351983
[TBL] [Abstract][Full Text] [Related]
8. Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology.
Ruan C; Yukihara EG; Clouse WJ; Gasparian PB; Ahmad S
Med Phys; 2010 Jul; 37(7):3560-8. PubMed ID: 20831063
[TBL] [Abstract][Full Text] [Related]
9. A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation.
Rupcich F; Badal A; Kyprianou I; Schmidt TG
Med Phys; 2012 Sep; 39(9):5336-46. PubMed ID: 22957601
[TBL] [Abstract][Full Text] [Related]
10. Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination.
Lee C; Lee C; Staton RJ; Hintenlang DE; Arreola MM; Williams JL; Bolch WE
Med Phys; 2007 May; 34(5):1858-73. PubMed ID: 17555267
[TBL] [Abstract][Full Text] [Related]
11. MicroCT imaging dose to mouse organs using a validated Monte Carlo model of the small animal radiation research platform (SARRP).
Johnstone CD; Bazalova-Carter M
Phys Med Biol; 2018 Jun; 63(11):115012. PubMed ID: 29741161
[TBL] [Abstract][Full Text] [Related]
12. New weighting factor of weighted CTDI equation for PMMA phantom diameter from 8 to 40 cm: A Monte Carlo study.
Haba T; Koyama S; Kinomura Y; Ida Y; Kobayashi M
Med Phys; 2017 Dec; 44(12):6603-6609. PubMed ID: 28960375
[TBL] [Abstract][Full Text] [Related]
13. On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations.
Perisinakis K; Tzedakis A; Damilakis J
Med Phys; 2008 May; 35(5):2018-28. PubMed ID: 18561678
[TBL] [Abstract][Full Text] [Related]
14. Prospective estimation of organ dose in CT under tube current modulation.
Tian X; Li X; Segars WP; Frush DP; Samei E
Med Phys; 2015 Apr; 42(4):1575-85. PubMed ID: 25832048
[TBL] [Abstract][Full Text] [Related]
15. Fast on-site Monte Carlo tool for dose calculations in CT applications.
Chen W; Kolditz D; Beister M; Bohle R; Kalender WA
Med Phys; 2012 Jun; 39(6):2985-96. PubMed ID: 22755683
[TBL] [Abstract][Full Text] [Related]
16. Correlation between X-ray tube current exposure time and X-ray photon number in GATE.
Romero IO; Fang Y; Li C
J Xray Sci Technol; 2022; 30(4):667-675. PubMed ID: 35466921
[TBL] [Abstract][Full Text] [Related]
17. Full modelling of the MOSAIC animal PET system based on the GATE Monte Carlo simulation code.
Merheb C; Petegnief Y; Talbot JN
Phys Med Biol; 2007 Feb; 52(3):563-76. PubMed ID: 17228105
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of organ doses in adult and paediatric CT examinations based on Monte Carlo simulations and in-phantom dosimetry.
Fujii K; Nomura K; Muramatsu Y; Takahashi K; Obara S; Akahane K; Satake M
Radiat Prot Dosimetry; 2015 Jul; 165(1-4):166-71. PubMed ID: 25848103
[TBL] [Abstract][Full Text] [Related]
19. Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image.
Wang J; Duan X; Christner JA; Leng S; Yu L; McCollough CH
Med Phys; 2012 Nov; 39(11):6764-71. PubMed ID: 23127070
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo assessment of CT dose equilibration in PMMA and water cylinders with diameters from 6 to 55 cm.
Li X; Zhang D; Liu B
Med Phys; 2013 Mar; 40(3):031903. PubMed ID: 23464318
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]