These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 26429441)

  • 1. Phillips-Tikhonov regularization with a priori information for neutron emission tomographic reconstruction on Joint European Torus.
    Bielecki J; Giacomelli L; Kiptily V; Scholz M; Drozdowicz K; Conroy S; Craciunescu T; Kempenaars M;
    Rev Sci Instrum; 2015 Sep; 86(9):093505. PubMed ID: 26429441
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of reconstruction errors and identification of artefacts for JET gamma and neutron tomography.
    Craciunescu T; Murari A; Kiptily V; Lupelli I; Fernandes A; Sharapov S; Tiseanu I; Zoita V;
    Rev Sci Instrum; 2016 Jan; 87(1):013502. PubMed ID: 26827316
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus.
    Giacomelli L; Conroy S; Gorini G; Horton L; Murari A; Popovichev S; Syme DB;
    Rev Sci Instrum; 2014 Feb; 85(2):023505. PubMed ID: 24593359
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimized tomography methods for plasma emissivity reconstruction at the ASDEX Upgrade tokamak.
    Odstrčil T; Pütterich T; Odstrčil M; Gude A; Igochine V; Stroth U;
    Rev Sci Instrum; 2016 Dec; 87(12):123505. PubMed ID: 28040918
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Maximum likelihood bolometric tomography for the determination of the uncertainties in the radiation emission on JET TOKAMAK.
    Craciunescu T; Peluso E; Murari A; Gelfusa M;
    Rev Sci Instrum; 2018 May; 89(5):053504. PubMed ID: 29864891
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Exploration of ion temperature profile measurements at JET using the upgraded neutron profile monitor.
    Marocco D; Esposito B; Riva M;
    Rev Sci Instrum; 2012 Oct; 83(10):10D314. PubMed ID: 23130788
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A high-resolution neutron spectroscopic camera for the SPARC tokamak based on the Jet European Torus deuterium-tritium experience.
    Tardocchi M; Rebai M; Rigamonti D; Tinguely RA; Caruggi F; Croci G; Dal Molin A; Ghani Z; Giacomelli L; Girolami M; Grosso G; Kushoro M; Marcer G; Mastellone M; Muraro A; Nocente M; Perelli Cippo E; Petruzzo M; Putignano O; Scionti J; Serpente V; Trucchi DM; Mackie S; Saltos AA; De Marchi E; Parisi M; Trotta A; de la Luna E; Garcia J; Kazakov Y; Maslov M; Stancar Z; Gorini G;
    Rev Sci Instrum; 2022 Nov; 93(11):113512. PubMed ID: 36461481
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An adaptive Tikhonov regularization method for fluorescence molecular tomography.
    Cao X; Zhang B; Wang X; Liu F; Liu K; Luo J; Bai J
    Med Biol Eng Comput; 2013 Aug; 51(8):849-58. PubMed ID: 23504309
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reconstruction of fluorescence molecular tomography using a neighborhood regularization.
    Li M; Cao X; Liu F; Zhang B; Luo J; Bai J
    IEEE Trans Biomed Eng; 2012 Jul; 59(7):1799-803. PubMed ID: 22514202
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Compressive sensing-based tomography for Absolute X-ray UltraViolet (AXUV) diagnostics.
    Yang M; Cheng Z; Wang S; Wang B; Tan Y; Gao Z
    Rev Sci Instrum; 2023 Jun; 94(6):. PubMed ID: 37862513
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neutron-stimulated emission computed tomography of a multi-element phantom.
    Floyd CE; Kapadia AJ; Bender JE; Sharma AC; Xia JQ; Harrawood BP; Tourassi GD; Lo JY; Crowell AS; Kiser MR; Howell CR
    Phys Med Biol; 2008 May; 53(9):2313-26. PubMed ID: 18421119
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [An image reconstruction algorithm based on L(P)-norm for magnetic induction tomography].
    Chen Y; Wang X; Yang D; Lu Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2013 Feb; 30(1):162-5. PubMed ID: 23488158
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A hybrid reconstruction method in electrical impedance tomography based on GMRES and Tikhonov regularization].
    Wang H; Fan W; Hu L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Aug; 26(4):701-5. PubMed ID: 19813592
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel combined regularization algorithm of total variation and Tikhonov regularization for open electrical impedance tomography.
    Liu J; Ling L; Li G
    Physiol Meas; 2013 Jul; 34(7):823-38. PubMed ID: 23787806
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Neutron emission spectroscopy of D plasmas at JET with a compact liquid scintillating neutron spectrometer.
    Giacomelli L; Belli F; Binda F; Conroy SW; Eriksson J; Milocco A; Popovicev S; Syme DB;
    Rev Sci Instrum; 2018 Oct; 89(10):10I113. PubMed ID: 30399806
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multilevel, hybrid regularization method for reconstruction of fluorescent molecular tomography.
    Yi H; Chen D; Qu X; Peng K; Chen X; Zhou Y; Tian J; Liang J
    Appl Opt; 2012 Mar; 51(7):975-86. PubMed ID: 22410902
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint.
    Cohen-Bacrie C; Goussard Y; Guardo R
    IEEE Trans Med Imaging; 1997 Oct; 16(5):562-71. PubMed ID: 9368111
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enhancing the performance of model-based elastography by incorporating additional a priori information in the modulus image reconstruction process.
    Doyley MM; Srinivasan S; Dimidenko E; Soni N; Ophir J
    Phys Med Biol; 2006 Jan; 51(1):95-112. PubMed ID: 16357433
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The selection of Tikhonov regularization parameter in dynamic electrical impedance imaging].
    Peng Y; Mo Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Dec; 20(4):571-3. PubMed ID: 14716847
    [TBL] [Abstract][Full Text] [Related]  

  • 20. First results of the resistive bolometers on KSTAR.
    Seo D; Peterson BJ; Lee SH
    Rev Sci Instrum; 2010 Oct; 81(10):10E128. PubMed ID: 21033992
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.