BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 26429854)

  • 1. First Reported Successful Femoral Valve-in-Valve Transcatheter Aortic Valve Replacement Using the Edwards Sapien 3 Valve.
    Fournier S; Monney P; Roguelov C; Zuffi A; Iglesias JF; Qanadli SD; Courbon C; Eeckhout E; Muller O
    J Invasive Cardiol; 2015 Oct; 27(10):E220-3. PubMed ID: 26429854
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Emergency transapical mitral valve-in-valve implantation for bioprosthesis failure: transapical implantation of an Edwards Sapien-XT in a dysfunctional mitral bioprosthesis in a critical patient.
    Zanobini M; Manganiello S; Bonalumi G; Biondi R; Russo M; Mapelli M; Alamanni F; Saccocci M
    J Cardiothorac Surg; 2017 Dec; 12(1):114. PubMed ID: 29237501
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transfemoral implantation of Edwards SAPIEN-XT
    Rogkakou C; Braun P; Kullmer M; Schöls W
    J Cardiol Cases; 2017 Oct; 16(4):131-133. PubMed ID: 30279816
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Successful Rescue Transaortic Valve Replacement Using Edwards Sapien 3 Following Failed Evolut R Implantation in a Degenerated Surgical Bioprosthesis: A Case Report.
    Molina-Lopez VH; Partida-Rodriguez E; Rivera-Babilonia J; Rodriguez-Ospina L
    Cureus; 2024 Feb; 16(2):e54318. PubMed ID: 38496184
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Successful valve-in-valve replacement using intravascular lithotripsy for femoral access in an elderly patient with critical aortic stenosis and extensive vascular calcification.
    Rivero-Santana B; Galeote G; Jurado-Roman A; Jiménez-Valero S; Gonzálvez-García A; Moreno R
    J Invasive Cardiol; 2024 May; ():. PubMed ID: 38776474
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Numerical models for assessing the risk of leaflet thrombosis post-transcatheter aortic valve-in-valve implantation.
    Plitman Mayo R; Yaakobovich H; Finkelstein A; Shadden SC; Marom G
    R Soc Open Sci; 2020 Dec; 7(12):201838. PubMed ID: 33489295
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Case Report: Double chimney in valve-in-valve procedures for high-risk coronary obstruction.
    Cook ST; Togni M; Cook S
    Front Cardiovasc Med; 2023; 10():1270782. PubMed ID: 38111894
    [TBL] [Abstract][Full Text] [Related]  

  • 8. IntraCardiac echocardiography-guided leaflet modification for coronary protection prior to transcatheter valve-in-valve replacement.
    Kodra A; Wang D; Mehla P; Goldberg Y; Mustafa A; Cinelli M; Scheinerman J; Kliger C
    J Invasive Cardiol; 2024 May; ():. PubMed ID: 38718283
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcatheter Aortic Valve Implantation in a Patient With Degenerated Aortic Homograft and Anomalous Right Coronary Artery Originating From Left Aortic Sinus.
    Muñoz-Rodríguez R; Bosa-Ojeda F; Yanes-Bowden G; Lacalzada-Almeida J
    CASE (Phila); 2023 Oct; 7(10):405-408. PubMed ID: 37970479
    [TBL] [Abstract][Full Text] [Related]  

  • 10. MitraClip and Transcatheter Aortic Valve Implantation (TAVI): State of the Art 2015.
    Candreva A; Maisano F; Taramasso M
    Curr Heart Fail Rep; 2015 Dec; 12(6):379-88. PubMed ID: 26472189
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves.
    Pache G; Schoechlin S; Blanke P; Dorfs S; Jander N; Arepalli CD; Gick M; Buettner HJ; Leipsic J; Langer M; Neumann FJ; Ruile P
    Eur Heart J; 2016 Jul; 37(28):2263-71. PubMed ID: 26446193
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Outcomes of transcatheter aortic valve implantation in high surgical risk and inoperable patients with aortic stenosis: a single Australian Centre experience.
    Subban V; Murdoch D; Savage ML; Crowhurst J; Saireddy R; Poon KK; Incani A; Bett N; Burstow DJ; Scalia GM; Clarke A; Raffel OC; Aroney CN; Walters DL
    Intern Med J; 2016 Jan; 46(1):42-51. PubMed ID: 26482426
    [TBL] [Abstract][Full Text] [Related]  

  • 13. National Analysis of Short-Term Outcomes and Volume-Outcome Relationships for Transcatheter Aortic Valve Replacement in the Era of Commercialization.
    de Biasi AR; Paul S; Nasar A; Girardi LN; Salemi A
    Cardiology; 2016; 133(1):58-68. PubMed ID: 26489084
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimizing clinical outcomes of transcatheter aortic valve implantation patients with comorbidities.
    O'Sullivan CJ; Wenaweser P
    Expert Rev Cardiovasc Ther; 2015 Dec; 13(12):1419-32. PubMed ID: 26479904
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Three-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing.
    Vaquerizo B; Spaziano M; Alali J; Mylote D; Theriault-Lauzier P; Alfagih R; Martucci G; Buithieu J; Piazza N
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):15-23. PubMed ID: 26429921
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In-hospital resource utilization in surgical and transcatheter aortic valve replacement.
    Reinöhl J; Kaier K; Gutmann A; Sorg S; von Zur Mühlen C; Siepe M; Baumbach H; Moser M; Geibel A; Zirlik A; Blanke P; Vach W; Beyersdorf F; Bode C; Zehender M
    BMC Cardiovasc Disord; 2015 Oct; 15():132. PubMed ID: 26494488
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Streamlining the learning process for TAVI: Insight from a comparative analysis of the OCEAN-TAVI and the massy registries.
    Inohara T; Hayashida K; Watanabe Y; Yamamoto M; Takagi K; Yashima F; Arai T; Shimizu H; Chevalier B; Lefèvre T; Fukuda K; Morice MC
    Catheter Cardiovasc Interv; 2016 Apr; 87(5):963-70. PubMed ID: 26489980
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Early Outcomes With Direct Flow Medical Versus First-Generation Transcatheter Aortic Valve Devices: A Single-Center Propensity-Matched Analysis.
    Giustino G; Latib A; Panoulas VF; Montorfano M; Chieffo A; Taramasso M; Sato K; Agricola E; Alfieri O; Colombo A
    J Interv Cardiol; 2015 Dec; 28(6):583-93. PubMed ID: 26487433
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Strategy of Underexpansion and Ad Hoc Post-Dilation of Balloon-Expandable Transcatheter Aortic Valves in Patients at Risk of Annular Injury: Favorable Mid-Term Outcomes.
    Tan JS; Leipsic J; Perlman G; Stub D; Dvir D; Hansson NC; Norgaard BL; Blanke P; Cheung A; Ye J; Thompson CR; Moss RR; Lauck S; Wood D; Webb J
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1727-32. PubMed ID: 26476612
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Incidence, Causes, and Predictors of Early (≤30 Days) and Late Unplanned Hospital Readmissions After Transcatheter Aortic Valve Replacement.
    Nombela-Franco L; del Trigo M; Morrison-Polo G; Veiga G; Jimenez-Quevedo P; Abdul-Jawad Altisent O; Campelo-Parada F; Biagioni C; Puri R; DeLarochellière R; Dumont E; Doyle D; Paradis JM; Quirós A; Almeria C; Gonzalo N; Nuñez-Gil I; Salinas P; Mohammadi S; Escaned J; Fernández-Ortiz A; Macaya C; Rodés-Cabau J
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1748-57. PubMed ID: 26476610
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.