These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 2643367)

  • 21. Efficacy of cell saver in reducing homologous blood transfusions during OPCAB surgery: a prospective randomized trial.
    Goel P; Pannu H; Mohan D; Arora R
    Transfus Med; 2007 Aug; 17(4):285-9. PubMed ID: 17680954
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Autotransfusion and emergency surgery: preliminary report on an improved technique.
    Olivero S; Enrichens F; Mao P; Benedetto G; Sciascia C
    Int J Artif Organs; 1985 Jul; 8(4):221-4. PubMed ID: 4055097
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Intraoperative washing of long-stored packed red blood cells by using an autotransfusion device prevents hyperkalemia.
    Knichwitz G; Zahl M; Van Aken H; Semjonow A; Booke M
    Anesth Analg; 2002 Aug; 95(2):324-5, table of contents. PubMed ID: 12145045
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Intraoperative red cell salvage.
    Fisher T
    Br J Perioper Nurs; 2004 Aug; 14(8):361-6. PubMed ID: 15378939
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Haptoglobin determination in the serum of patients following intraoperative autotransfusion using the Haemonetics Cell Saver III. Studies on the loading of patients with free hemoglobin in retransfused erythrocyte concentrate].
    Henn A; Hoffmann R; Müller HA
    Anaesthesist; 1988 Dec; 37(12):741-5. PubMed ID: 3218723
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Intraoperative autologous blood collection and autotransfusion in the surgical management of early cancers of the uterine cervix.
    Connor JP; Morris PC; Alagoz T; Anderson B; Bottles K; Buller RE
    Obstet Gynecol; 1995 Sep; 86(3):373-8. PubMed ID: 7651645
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Potential problems with autotransfusion during hepatic transplantation.
    Brajtbord D; Paulsen AW; Ramsay MA; Swygert TH; Valek TR; Ramon VJ; Johnson DD; Parks RI; Pyron JT; Walling PT
    Transplant Proc; 1989 Feb; 21(1 Pt 2):2347-8. PubMed ID: 2652762
    [No Abstract]   [Full Text] [Related]  

  • 28. [Intraoperative hemodilutional autotransfusion using a closed circuit for patients of Jehovah's Witness].
    Hiraki T; Hamada N; Kano T; Isamoto Y
    Masui; 2000 May; 49(5):535-9. PubMed ID: 10846387
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [A comparison of autologous transfusion procedures in hip surgery].
    Lorentz A; Osswald PM; Schilling M; Jani L
    Anaesthesist; 1991 Apr; 40(4):205-13. PubMed ID: 2058822
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [The Haemonetics cell saver in open heart surgery (author's transl)].
    Saggau W; Späth J; Tanzeem A; Storch HH; Schmitz W
    Anasth Intensivther Notfallmed; 1982 Feb; 17(1):51-7. PubMed ID: 7065387
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Autotransfusion and erythrocyte washing. Technic and application in cardiac surgery].
    Chauvaud S; Massonet-Castel S; Pelissier E; d'Allaines C; Carpentier A
    Chirurgie; 1984; 110(1):63-9. PubMed ID: 6734349
    [No Abstract]   [Full Text] [Related]  

  • 32. [Autotransfusion using Cell Saver III. Experience with 90 cases of surgery of the spine in childhood and adolescence].
    Gaudiche O; Loose JP; Egu JF; Dubousset J; Saint-Maurice C
    Cah Anesthesiol; 1988 Oct; 36(6):451-7. PubMed ID: 3214771
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Difference in efficacy of the Cell Saver in coronary bypass grafting surgery and cardiac valvular reoperations.
    Wang MJ; Chen TL; Huang CH; Chao A; Chu SH
    J Formos Med Assoc; 1994 Feb; 93(2):117-21. PubMed ID: 7912581
    [TBL] [Abstract][Full Text] [Related]  

  • 34. An autotransfusion apparatus.
    Johnston B; Kamath BS; McLellan I
    Anaesthesia; 1977; 32(10):1020-3. PubMed ID: 596589
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Use of Cell Saver 4 in traumatology. Apropos of 9 cases].
    Cantais R; Coquelin G; Petit D; Stephanazi J; Quinot JF
    Cah Anesthesiol; 1992; 40(4):289-91. PubMed ID: 1477749
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Blood-saving effectiveness of preoperative reservation of autoblood for surgical treatment of ischemic heart disease].
    Naumenko SE; Pokrovskiĭ MG; Belavin AS; Kim SF
    Vestn Khir Im I I Grek; 2003; 162(2):59-64. PubMed ID: 14606149
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Autologous blood replacement in urology].
    Faul P; Partecke G
    Infusionstherapie; 1990 Apr; 17 Suppl 2():41-2. PubMed ID: 1695616
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Intraoperative mechanical autotransfusion: examination of the withdrawn blood before retransfusion].
    Anaesthesist; 1985 May; 34(5):255-60. PubMed ID: 4025795
    [No Abstract]   [Full Text] [Related]  

  • 39. [Autotransfusion. Intraoperative autologous transfusion of washed red cells].
    Pillgram-Larsen J; Pedersen TH; Karlsen H; Semb G
    Tidsskr Nor Laegeforen; 1987 Jan; 107(2):158-60. PubMed ID: 3824305
    [No Abstract]   [Full Text] [Related]  

  • 40. Exchange Autotransfusion for Rapid Correction of Hyperkalemia During Liver Transplantation: A Case Report.
    Yoon U; Gerney G; Hsu G; Elia E; Kang Y
    A A Pract; 2019 Jan; 12(1):15-18. PubMed ID: 29985842
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.