21. Reducing false alarms in the ICU by quantifying self-similarity of multimodal biosignals.
Antink CH; Leonhardt S; Walter M
Physiol Meas; 2016 Aug; 37(8):1233-52. PubMed ID: 27454256
[TBL] [Abstract][Full Text] [Related]
22. Reducing false arrhythmia alarm rates using robust heart rate estimation and cost-sensitive support vector machines.
Zhang Q; Chen X; Fang Z; Zhan Q; Yang T; Xia S
Physiol Meas; 2017 Feb; 38(2):259-271. PubMed ID: 28099159
[TBL] [Abstract][Full Text] [Related]
23. False ventricular tachycardia alarm suppression in the ICU based on the discrete wavelet transform in the ECG signal.
Salas-Boni R; Bai Y; Harris PR; Drew BJ; Hu X
J Electrocardiol; 2014; 47(6):775-80. PubMed ID: 25172188
[TBL] [Abstract][Full Text] [Related]
24. Signal quality and data fusion for false alarm reduction in the intensive care unit.
Li Q; Clifford GD
J Electrocardiol; 2012; 45(6):596-603. PubMed ID: 22960167
[TBL] [Abstract][Full Text] [Related]
25. Taming of the monitors: reducing false alarms in intensive care units.
Plesinger F; Klimes P; Halamek J; Jurak P
Physiol Meas; 2016 Aug; 37(8):1313-25. PubMed ID: 27454821
[TBL] [Abstract][Full Text] [Related]
26. Automated False Alarm Reduction in a Real-Life Intensive Care Setting Using Motion Detection.
Muroi C; Meier S; De Luca V; Mack DJ; Strässle C; Schwab P; Karlen W; Keller E
Neurocrit Care; 2020 Apr; 32(2):419-426. PubMed ID: 31290067
[TBL] [Abstract][Full Text] [Related]
27. Physiologic monitoring alarm load on medical/surgical floors of a community hospital.
Gross B; Dahl D; Nielsen L
Biomed Instrum Technol; 2011; Suppl():29-36. PubMed ID: 21599479
[TBL] [Abstract][Full Text] [Related]
28. Particle Filtering and Sensor Fusion for Robust Heart Rate Monitoring Using Wearable Sensors.
Nathan V; Jafari R
IEEE J Biomed Health Inform; 2018 Nov; 22(6):1834-1846. PubMed ID: 29990023
[TBL] [Abstract][Full Text] [Related]
29. Robust sensor fusion improves heart rate estimation: clinical evaluation.
Feldman JM; Ebrahim MH; Bar-Kana I
J Clin Monit; 1997 Nov; 13(6):379-84. PubMed ID: 9495290
[TBL] [Abstract][Full Text] [Related]
30. An expert system for monitor alarm integration.
Oberli C; Urzua J; Saez C; Guarini M; Ciprianio A; Garayar B; Lema G; Canessa R; Sacco C; Irarrazaval M
J Clin Monit Comput; 1999 Jan; 15(1):29-35. PubMed ID: 12578059
[TBL] [Abstract][Full Text] [Related]
31. Research: Association of Low-Amplitude QRSs with False-Positive Asystole Alarms.
Pelter MM; Fidler R; Hu X
Biomed Instrum Technol; 2016; 50(5):329-35. PubMed ID: 27632038
[TBL] [Abstract][Full Text] [Related]
32. Advanced clinical monitoring: considerations for real-time hemodynamic diagnostics.
Goldman JM; Cordova MJ
Proc Annu Symp Comput Appl Med Care; 1994; ():752-6. PubMed ID: 7950025
[TBL] [Abstract][Full Text] [Related]
33. Reducing false intracranial pressure alarms using morphological waveform features.
Scalzo F; Liebeskind D; Hu X
IEEE Trans Biomed Eng; 2013 Jan; 60(1):235-9. PubMed ID: 22851230
[TBL] [Abstract][Full Text] [Related]
34. Robust Interbeat Interval and Heart Rate Variability Estimation Method From Various Morphological Features Using Wearable Sensors.
Aygun A; Ghasemzadeh H; Jafari R
IEEE J Biomed Health Inform; 2020 Aug; 24(8):2238-2250. PubMed ID: 31899444
[TBL] [Abstract][Full Text] [Related]
35. Automatic detection of distorted plethysmogram pulses in neonates and paediatric patients using an adaptive-network-based fuzzy inference system.
Belal SY; Taktak AF; Nevill AJ; Spencer SA; Roden D; Bevan S
Artif Intell Med; 2002 Feb; 24(2):149-65. PubMed ID: 11830368
[TBL] [Abstract][Full Text] [Related]
36. Adaptive nocturnal seizure detection using heart rate and low-complexity novelty detection.
De Cooman T; Varon C; Van de Vel A; Jansen K; Ceulemans B; Lagae L; Van Huffel S
Seizure; 2018 Jul; 59():48-53. PubMed ID: 29747021
[TBL] [Abstract][Full Text] [Related]
37. A novel ECG detector performance metric and its relationship with missing and false heart rate limit alarms.
Daluwatte C; Vicente J; Galeotti L; Johannesen L; Strauss DG; Scully CG
J Electrocardiol; 2018; 51(1):68-73. PubMed ID: 28964425
[TBL] [Abstract][Full Text] [Related]
38. Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring.
Hoog Antink C; Schulz F; Leonhardt S; Walter M
Sensors (Basel); 2017 Dec; 18(1):. PubMed ID: 29295594
[TBL] [Abstract][Full Text] [Related]
39. False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.
Tanantong T; Nantajeewarawat E; Thiemjarus S
Sensors (Basel); 2015 Feb; 15(2):3952-74. PubMed ID: 25671512
[TBL] [Abstract][Full Text] [Related]
40. Fuzzy entropy based motion artifact detection and pulse rate estimation for fingertip photoplethysmography.
Paradkar N; Chowdhury SR
Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():58-61. PubMed ID: 25569896
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]