  • 1. Detecting glaucomatous change in visual fields: Analysis with an optimization framework.
    Yousefi S; Goldbaum MH; Varnousfaderani ES; Belghith A; Jung TP; Medeiros FA; Zangwill LM; Weinreb RN; Liebmann JM; Girkin CA; Bowd C
    J Biomed Inform; 2015 Dec; 58():96-103. PubMed ID: 26440445
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Glaucomatous visual field progression with frequency-doubling technology and standard automated perimetry in a longitudinal prospective study.
    Haymes SA; Hutchison DM; McCormick TA; Varma DK; Nicolela MT; LeBlanc RP; Chauhan BC
    Invest Ophthalmol Vis Sci; 2005 Feb; 46(2):547-54. PubMed ID: 15671281
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Frequency doubling technology perimetry abnormalities as predictors of glaucomatous visual field loss.
    Medeiros FA; Sample PA; Weinreb RN
    Am J Ophthalmol; 2004 May; 137(5):863-71. PubMed ID: 15126151
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Frequency doubling technology perimetry for detection of visual field progression in glaucoma: a pointwise linear regression analysis.
    Liu S; Yu M; Weinreb RN; Lai G; Lam DS; Leung CK
    Invest Ophthalmol Vis Sci; 2014 May; 55(5):2862-9. PubMed ID: 24595388
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.
    Sample PA; Bosworth CF; Blumenthal EZ; Girkin C; Weinreb RN
    Invest Ophthalmol Vis Sci; 2000 Jun; 41(7):1783-90. PubMed ID: 10845599
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Humphrey matrix frequency doubling perimetry for detection of visual-field defects in open-angle glaucoma.
    Clement CI; Goldberg I; Healey PR; Graham S
    Br J Ophthalmol; 2009 May; 93(5):582-8. PubMed ID: 18669543
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of progressive change in automated visual fields in glaucoma.
    Smith SD; Katz J; Quigley HA
    Invest Ophthalmol Vis Sci; 1996 Jun; 37(7):1419-28. PubMed ID: 8641844
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Learning from data: recognizing glaucomatous defect patterns and detecting progression from visual field measurements.
    Yousefi S; Goldbaum MH; Balasubramanian M; Medeiros FA; Zangwill LM; Liebmann JM; Girkin CA; Weinreb RN; Bowd C
    IEEE Trans Biomed Eng; 2014 Jul; 61(7):2112-24. PubMed ID: 24710816
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Frequency-doubling technology perimetry for detection of the development of visual field defects in glaucoma suspect eyes: a prospective study.
    Liu S; Yu M; Weinreb RN; Lai G; Lam DS; Leung CK
    JAMA Ophthalmol; 2014 Jan; 132(1):77-83. PubMed ID: 24177945
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Combining structural and functional testing for detection of glaucoma.
    Shah NN; Bowd C; Medeiros FA; Weinreb RN; Sample PA; Hoffmann EM; Zangwill LM
    Ophthalmology; 2006 Sep; 113(9):1593-602. PubMed ID: 16949444
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Visual field progression in glaucoma: cluster analysis].
    Bresson-Dumont H; Hatton J; Foucher J; Fonteneau M
    J Fr Ophtalmol; 2012 Nov; 35(9):735-41. PubMed ID: 22771181
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Retinal nerve fiber layer thickness measurements with scanning laser polarimetry predict glaucomatous visual field loss.
    Mohammadi K; Bowd C; Weinreb RN; Medeiros FA; Sample PA; Zangwill LM
    Am J Ophthalmol; 2004 Oct; 138(4):592-601. PubMed ID: 15488786
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparing multifocal VEP and standard automated perimetry in high-risk ocular hypertension and early glaucoma.
    Fortune B; Demirel S; Zhang X; Hood DC; Patterson E; Jamil A; Mansberger SL; Cioffi GA; Johnson CA
    Invest Ophthalmol Vis Sci; 2007 Mar; 48(3):1173-80. PubMed ID: 17325161
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Glaucoma diagnostics.
    Geimer SA
    Acta Ophthalmol; 2013 Feb; 91 Thesis 1():1-32. PubMed ID: 23384049
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma.
    Artes PH; Hutchison DM; Nicolela MT; LeBlanc RP; Chauhan BC
    Invest Ophthalmol Vis Sci; 2005 Jul; 46(7):2451-7. PubMed ID: 15980235
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Unsupervised learning with independent component analysis can identify patterns of glaucomatous visual field defects.
    Goldbaum MH
    Trans Am Ophthalmol Soc; 2005; 103():270-80. PubMed ID: 17057807
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The ability of short-wavelength automated perimetry to predict conversion to glaucoma.
    van der Schoot J; Reus NJ; Colen TP; Lemij HG
    Ophthalmology; 2010 Jan; 117(1):30-4. PubMed ID: 19896194
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.
    Liu S; Lam S; Weinreb RN; Ye C; Cheung CY; Lai G; Lam DS; Leung CK
    Invest Ophthalmol Vis Sci; 2011 Sep; 52(10):7325-31. PubMed ID: 21810975
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detectability of glaucomatous changes using SAP, FDT, flicker perimetry, and OCT.
    Nomoto H; Matsumoto C; Takada S; Hashimoto S; Arimura E; Okuyama S; Shimomura Y
    J Glaucoma; 2009 Feb; 18(2):165-71. PubMed ID: 19225357
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Visual field progression with frequency-doubling matrix perimetry and standard automated perimetry in patients with glaucoma and in healthy controls.
    Redmond T; O'Leary N; Hutchison DM; Nicolela MT; Artes PH; Chauhan BC
    JAMA Ophthalmol; 2013 Dec; 131(12):1565-72. PubMed ID: 24177807