These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
84 related articles for article (PubMed ID: 26447362)
1. Does the St. Jude Regent 17-mm Offer Better Outcomes Than the Hemodynamic Plus 17-mm Aortic Valve Mechanical Prothesis? Prifti E; Bonacchi M; Baboci A; Giunti G; Esposito G; Kajo E; Nuellari E; Vanini V J Card Surg; 2015 Nov; 30(11):787-95. PubMed ID: 26447362 [TBL] [Abstract][Full Text] [Related]
2. Early and mid-term functional and hemodynamic evaluation of the St. Jude Medical Regent 17 mm aortic valve mechanical prosthesis. Prifti E; Bonacchi M; Baboci A; Krakulli K; Giunti G J Heart Valve Dis; 2014 Jan; 23(1):112-21. PubMed ID: 24779337 [TBL] [Abstract][Full Text] [Related]
3. Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis. Prifti E; Bonacchi M; Ademaj F; Giunti G; Esposito G; Baboci A; Bajraktari G; Veshti A; Demiraj A; Vanini V J Cardiothorac Surg; 2015 Nov; 10():154. PubMed ID: 26541289 [TBL] [Abstract][Full Text] [Related]
4. Early and Mid-term Outcome of the St. Jude Medical Regent 19-mm Aortic Valve Mechanical Prosthesis. Functional and Haemodynamic Evaluation. Prifti E; Bonacchi M; Minardi G; Krakulli K; Baboci A; Esposito G; Demiraj A; Zeka M; Rruci E Heart Lung Circ; 2018 Feb; 27(2):235-247. PubMed ID: 28400190 [TBL] [Abstract][Full Text] [Related]
5. Hemodynamics of 17-mm vs. 19-mm St. Jude Medical Regent and annulus enlargement. Prifti E; Bonacchi M; Baboci A; Giunti G; Esposito G; Krakulli K; Ademaj F; Kajo E; Vanini V Asian Cardiovasc Thorac Ann; 2015 Jul; 23(6):670-83. PubMed ID: 25931567 [TBL] [Abstract][Full Text] [Related]
6. Hemodynamic function of the standard St. Jude bileaflet disc valve has no clinical impact 10 years after aortic valve replacement. Lund O; Dørup I; Emmertsen K; Jensen FT; Flø C Scand Cardiovasc J; 2005 Sep; 39(4):237-43. PubMed ID: 16118072 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography. Minardi G; Manzara C; Creazzo V; Maselli D; Casali G; Pulignano G; Musumeci F J Cardiothorac Surg; 2006 Sep; 1():27. PubMed ID: 16984626 [TBL] [Abstract][Full Text] [Related]
9. Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis. Amarelli C; Della Corte A; Romano G; Iasevoli G; Dialetto G; De Santo LS; De Feo M; Torella M; Scardone M; Cotrufo M J Thorac Cardiovasc Surg; 2005 Mar; 129(3):512-7. PubMed ID: 15746732 [TBL] [Abstract][Full Text] [Related]
10. [Early and mid-term results after 17 mm St Jude Regent mechanical valve replacement in 44 patients with small aortic root]. Zhu P; Zheng SY; Mai MJ; Zhuang J; Chen JM; Chen XQ; Chen PJ; Wu RB Nan Fang Yi Ke Da Xue Xue Bao; 2010 Apr; 30(4):799-801. PubMed ID: 20423854 [TBL] [Abstract][Full Text] [Related]
11. Early in vivo hemodynamic results after aortic valve replacement with the St Jude Medical Regent mechanical heart valve in patients with pure aortic stenosis. Gelsomino S; Morocutti G; Da Col P; Masullo G; Carella R; Guzzi G; Spedicato L; Livi U J Card Surg; 2003; 18(2):125-32. PubMed ID: 12757339 [TBL] [Abstract][Full Text] [Related]
12. Hemodynamics after aortic valve replacement with St. Jude Medical valve for patients with small aortic annulus and severe left ventricular hypertrophy. Natsuaki M; Itoh T; Tomita S; Naitoh K J Heart Valve Dis; 1998 Jan; 7(1):86-93. PubMed ID: 9502145 [TBL] [Abstract][Full Text] [Related]
13. Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly. Roscitano A; Benedetto U; Sciangula A; Merico E; Barberi F; Bianchini R; Tonelli E; Sinatra R Eur J Cardiothorac Surg; 2006 Feb; 29(2):139-43. PubMed ID: 16376565 [TBL] [Abstract][Full Text] [Related]
14. [Mid-long-term clinical results and hemodynamic evaluation of aortic valve replacement with 17 mm St. Jude medical regent valve]. Liu Y; Zhang EY; Fang Z; Gu J; Qian H Sichuan Da Xue Xue Bao Yi Xue Ban; 2013 Mar; 44(2):316-8, 326. PubMed ID: 23745280 [TBL] [Abstract][Full Text] [Related]
15. Standard versus hemodynamic plus 19-mm St Jude Medical aortic valves. Ismeno G; Renzulli A; De Feo M; Della Corte A; Covino FE; Cotrufo M J Thorac Cardiovasc Surg; 2001 Apr; 121(4):723-8. PubMed ID: 11279414 [TBL] [Abstract][Full Text] [Related]
16. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm). Kato Y; Hattori K; Motoki M; Takahashi Y; Kotani S; Nishimura S; Shibata T J Heart Valve Dis; 2013 Jul; 22(4):468-75. PubMed ID: 24224408 [TBL] [Abstract][Full Text] [Related]
17. Hemodynamics and outcomes of aortic valve replacement with a 17- or 19-mm valve. Okamura H; Yamaguchi A; Noguchi K; Naito K; Yuri K; Adachi H Asian Cardiovasc Thorac Ann; 2010 Oct; 18(5):450-5. PubMed ID: 20947599 [TBL] [Abstract][Full Text] [Related]
18. Early postoperative outcome and hemodynamic performance of the sorin pericarbon stentless aortic valve. Bonacchi M; Giunti G; Prifti E; Rostagno C; Bini M; Frati G; Sani G J Heart Valve Dis; 2002 Sep; 11(5):703-9. PubMed ID: 12358408 [TBL] [Abstract][Full Text] [Related]
19. Early in vivo experience with the Hemodynamic Plus St. Jude Medical heart valves in patients with narrowed aortic annulus. Carrel T; Zingg U; Jenni R; Aeschbacher B; Turina MI Ann Thorac Surg; 1996 May; 61(5):1418-22. PubMed ID: 8633952 [TBL] [Abstract][Full Text] [Related]
20. Left ventricular mass regression is independent of gradient drop and effective orifice area after aortic valve replacement with a porcine bioprosthesis. Sádaba JR; Herregods MC; Bogaert J; Harringer W; Gerosa G J Heart Valve Dis; 2012 Nov; 21(6):788-94. PubMed ID: 23409363 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]