These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 26449936)

  • 1. A Novel Algorithm for Pacemaker-Mediated Tachycardia: Wrong Diagnosis, Right Therapy.
    Ip JE; Cheung JW; Markowitz SM; Lerman BB
    Pacing Clin Electrophysiol; 2016 Mar; 39(3):302-4. PubMed ID: 26449936
    [No Abstract]   [Full Text] [Related]  

  • 2. Ventricular safety pacing, ventricular sense response, and ventricular tachycardia.
    Lim S
    Heart Rhythm; 2010 Apr; 7(4):567-9. PubMed ID: 20056499
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anodal capture in cardiac resynchronization therapy implications for device programming.
    Tamborero D; Mont L; Alanis R; Berruezo A; Tolosana JM; Sitges M; Vidal B; Brugada J
    Pacing Clin Electrophysiol; 2006 Sep; 29(9):940-5. PubMed ID: 16981916
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pacemaker-mediated tachycardia initiated by an atrioventricular search algorithm to minimize right ventricular pacing.
    Barold SS; Stroobandt RX
    J Electrocardiol; 2012; 45(3):336-9. PubMed ID: 22280797
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Can Autocapture™ Function of Permanent Pacemakers Initiate Ventricular Tachyarrhythmias?
    Akdemir B; Vakil K; Benditt D; Adabag S
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):92-4. PubMed ID: 26227566
    [No Abstract]   [Full Text] [Related]  

  • 6. Repetitive non-reentrant VA synchrony and pacemaker-mediated tachycardia induced by the AF suppression algorithm.
    Kohno R; Abe H; Nagatomo T; Otsuji Y
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1333-5. PubMed ID: 19732366
    [No Abstract]   [Full Text] [Related]  

  • 7. Interventricular Pacemaker-Mediated Tachycardia during Biventricular Pacing.
    Barold SS; Delnoy PP; Kucher A
    Pacing Clin Electrophysiol; 2015 May; 38(5):645-50. PubMed ID: 24797447
    [No Abstract]   [Full Text] [Related]  

  • 8. Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study.
    Ricci RP; Botto GL; Bénézet JM; Nielsen JC; De Roy L; Piot O; Quesada A; Quaglione R; Vaccari D; Mangoni L; Grammatico A; Kozák M;
    Heart Rhythm; 2015 Nov; 12(11):2239-46. PubMed ID: 26142300
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wide complex tachycardia in a patient with a dual chamber pacemaker.
    Keuleers S; Ferdinande B; Huybrechts W; Willems R
    Europace; 2009 Jan; 11(1):125-8. PubMed ID: 19028708
    [No Abstract]   [Full Text] [Related]  

  • 10. Enhanced Pacemaker Detection software-induced electrocardiographic artifact.
    Kang JS; Simpson CS; Redfearn DP; Shaw C; Baranchuk A
    J Electrocardiol; 2008; 41(1):6-7. PubMed ID: 17888940
    [No Abstract]   [Full Text] [Related]  

  • 11. Pacemakers do not always tell the truth: diagnosis of ventricular tachycardia for supraventricular tachycardia on pacemaker telemetry.
    Bayrak F; de Asmundis C; Chierchia GB; Brugada P
    Turk Kardiyol Dern Ars; 2011 Dec; 39(8):683-5. PubMed ID: 22257807
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Possible role of a common pacing algorithm in initiation of ventricular arrhythmia.
    Pavri BB
    Pacing Clin Electrophysiol; 2009 May; 32(5):663-6. PubMed ID: 19422590
    [No Abstract]   [Full Text] [Related]  

  • 13. Temporary transvenous pacemaker placement: what criteria constitute an adequate pacing site?
    Goldberger J; Kruse J; Ehlert FA; Kadish A
    Am Heart J; 1993 Aug; 126(2):488-93. PubMed ID: 8338033
    [No Abstract]   [Full Text] [Related]  

  • 14. Accuracy of the pacemaker-mediated tachycardia algorithm in Boston Scientific devices.
    Strik M; Frontera A; Eschalier R; Defaye P; Mondoly P; Ritter P; Haïssaguerre M; Ploux S; Bordachar P
    J Electrocardiol; 2016; 49(4):522-9. PubMed ID: 27199031
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mode switching during managed ventricular pacing algorithm: what is the mechanism?
    Almehairi M; Simpson C; Caldwell JC; Baranchuk A
    Pacing Clin Electrophysiol; 2014 May; 37(5):646-9. PubMed ID: 23998558
    [No Abstract]   [Full Text] [Related]  

  • 16. Pacemaker update. Part IV: Antitachycardia devices.
    Futterman LG; Lemberg L
    Am J Crit Care; 1993 May; 2(3):253-5. PubMed ID: 8364677
    [No Abstract]   [Full Text] [Related]  

  • 17. Pacemaker-mediated tachycardia with varying cycle length: what is the mechanism?
    Verrijcken A; Huybrechts W; Willems R
    Europace; 2009 Oct; 11(10):1400-2. PubMed ID: 19578056
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The origin of epicardial ventricular tachycardia revealed by entrainment from a permanent epicardial left ventricular pacing lead.
    Inada K; Rosman J; Couper G; Tedrow UB
    J Cardiovasc Electrophysiol; 2010 Nov; 21(11):1293-5. PubMed ID: 20662982
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pacemaker tachycardia: is it pacemaker-mediated tachycardia or sinus tachycardia?
    Barold SS; Leonelli F; Khan N; Cutro R; Herweg B
    Pacing Clin Electrophysiol; 2007 Feb; 30(2):256-7. PubMed ID: 17338724
    [No Abstract]   [Full Text] [Related]  

  • 20. Performance evaluation of a right atrial automatic capture verification algorithm using two different sensing configurations.
    Sperzel J; Goetze S; Kennergren C; Biffi M; Brooke MJ; Vireca E; Saha S; Schubert B; Butter C
    Pacing Clin Electrophysiol; 2009 May; 32(5):579-87. PubMed ID: 19422578
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.