These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 2645206)

  • 1. Local tissue attenuation images based on pulsed-echo ultrasound scans.
    Walach E; Shmulewitz A; Itzchak Y; Heyman Z
    IEEE Trans Biomed Eng; 1989 Feb; 36(2):211-21. PubMed ID: 2645206
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrasound compounding with automatic attenuation compensation using paired angle scans.
    Treece GM; Gee AH; Prager RW
    Ultrasound Med Biol; 2007 Apr; 33(4):630-42. PubMed ID: 17320269
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
    Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
    J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Constrained least squares filtering algorithm for ultrasound image deconvolution.
    Yeoh WS; Zhang C
    IEEE Trans Biomed Eng; 2006 Oct; 53(10):2001-7. PubMed ID: 17019864
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Robust estimation of ultrasound pulses using outlier-resistant de-noising.
    Michailovich O; Adam D
    IEEE Trans Med Imaging; 2003 Mar; 22(3):368-81. PubMed ID: 12760554
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A quadrature demodulation method based on tracking the ultrasound echo frequency.
    Feng N; Zhang J; Wang W
    Ultrasonics; 2006 Dec; 44 Suppl 1():e47-50. PubMed ID: 16860363
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance improvement of the SPIHT coder based on statistics of medical ultrasound images in the wavelet domain.
    Kaur L; Chauhan RC; Saxena SC
    J Med Eng Technol; 2005; 29(6):297-301. PubMed ID: 16287679
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Boundary enhancement and speckle reduction for ultrasound images via salient structure extraction.
    Xie J; Jiang Y; Tsui HT; Heng PA
    IEEE Trans Biomed Eng; 2006 Nov; 53(11):2300-9. PubMed ID: 17073336
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The analysis and comparison of different edge detection algorithms in ultrasound B-scan images].
    Zhang LP; Yang BY; Wang CH
    Zhongguo Yi Liao Qi Xie Za Zhi; 2006 May; 30(3):170-2. PubMed ID: 16929771
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Volume quantification by fuzzy logic modelling in freehand ultrasound imaging.
    Betrouni N; Lopes R; Makni N; Dewalle AS; Vermandel M; Rousseau J
    Ultrasonics; 2009 Dec; 49(8):646-52. PubMed ID: 19409591
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A method to expedite data acquisition for multiple spatial-temporal analyses of tissue perfusion by contrast-enhanced ultrasound.
    Hansen C; Hüttebräuker N; Wilkening W; Ermert H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Mar; 56(3):507-19. PubMed ID: 19411210
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sensitivity to point-spread function parameters in medical ultrasound image deconvolution.
    Shin HC; Prager R; Ng J; Gomersall H; Kingsbury N; Treece G; Gee A
    Ultrasonics; 2009 Mar; 49(3):344-57. PubMed ID: 19068260
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detection of lines and boundaries in speckle images--application to medical ultrasound.
    Czerwinski RN; Jones DL; O'Brien WD
    IEEE Trans Med Imaging; 1999 Feb; 18(2):126-36. PubMed ID: 10232669
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Differential ultrasonic imaging for the characterization of lesions induced by high intensity focused ultrasound.
    Zhong H; Wan M; Jiang Y; Wang S
    Ultrasonics; 2006 Dec; 44 Suppl 1():e285-8. PubMed ID: 16844167
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reconstruction of volumetric ultrasound panorama based on improved 3D SIFT.
    Ni D; Chui YP; Qu Y; Yang X; Qin J; Wong TT; Ho SS; Heng PA
    Comput Med Imaging Graph; 2009 Oct; 33(7):559-66. PubMed ID: 19524403
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Homomorphic wavelet thresholding technique for denoising medical ultrasound images.
    Gupta S; Chauhan RC; Saxena SC
    J Med Eng Technol; 2005; 29(5):208-14. PubMed ID: 16126580
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An efficient sound speed estimation method to enhance image resolution in ultrasound imaging.
    Cho MH; Kang LH; Kim JS; Lee SY
    Ultrasonics; 2009 Dec; 49(8):774-8. PubMed ID: 19635626
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hybrid spectral domain method for attenuation slope estimation.
    Kim H; Varghese T
    Ultrasound Med Biol; 2008 Nov; 34(11):1808-19. PubMed ID: 18621468
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid elastic image registration for 3-D ultrasound.
    Krücker JF; LeCarpentier GL; Fowlkes JB; Carson PL
    IEEE Trans Med Imaging; 2002 Nov; 21(11):1384-94. PubMed ID: 12575875
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sensorless freehand 3D ultrasound in real tissue: speckle decorrelation without fully developed speckle.
    Gee AH; James Housden R; Hassenpflug P; Treece GM; Prager RW
    Med Image Anal; 2006 Apr; 10(2):137-49. PubMed ID: 16143560
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.