BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

288 related articles for article (PubMed ID: 26453527)

  • 1. Influence of needle diameter on spinal anaesthesia puncture failures for caesarean section: A prospective, randomised, experimental study.
    Fama' F; Linard C; Bierlaire D; Gioffre'-Florio M; Fusciardi J; Laffon M
    Anaesth Crit Care Pain Med; 2015 Oct; 34(5):277-80. PubMed ID: 26453527
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Post dural puncture headache after spinal anaesthesia for caesarean section: a comparison of 25 g Quincke, 27 g Quincke and 27 g Whitacre spinal needles.
    Shaikh JM; Memon A; Memon MA; Khan M
    J Ayub Med Coll Abbottabad; 2008; 20(3):10-3. PubMed ID: 19610505
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of spinal needle design and approach to postdural puncture headache and spinal anesthesia failure in obstetrics.
    Batova R; Georgiev S
    Anaesthesiol Intensive Ther; 2019; 51(2):77-82. PubMed ID: 31268266
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Development of incidence of post-dural puncture headache in patients undergoing caesarean section in spinal anaesthesia at the Department of Obstetrics and Gynecology in Olomouc during 2003-2004].
    L'ubuský M; Berta E; Procházka M; Marek O; Kudela M
    Cas Lek Cesk; 2006; 145(3):204-8. PubMed ID: 16634479
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of the 25-gauge Whitacre with the 24-gauge Sprotte spinal needle for elective caesarean section: cost implications.
    Campbell DC; Douglas MJ; Pavy TJ; Merrick P; Flanagan ML; McMorland GH
    Can J Anaesth; 1993 Dec; 40(12):1131-5. PubMed ID: 8281588
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of 25 G and 27 G Whitacre needles for caesarean section.
    Smith EA; Thorburn J; Duckworth RA; Reid JA
    Anaesthesia; 1994 Oct; 49(10):859-62. PubMed ID: 7802179
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Spinal anaesthesia for caesarean section: comparison of 22-gauge and 25-gauge Whitacre needles with 26-gauge Quincke needles.
    Shutt LE; Valentine SJ; Wee MY; Page RJ; Prosser A; Thomas TA
    Br J Anaesth; 1992 Dec; 69(6):589-94. PubMed ID: 1467102
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Paresthesia in various spinal anesthesia techniques for cesarean section].
    Abizanda FP; Reina MA; Ruiz IF; García AL; López MA; Sendín PM
    Rev Esp Anestesiol Reanim; 2007 Nov; 54(9):529-36. PubMed ID: 18085105
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparative multicentre trial of spinal needles for caesarean section.
    Hopkinson JM; Samaan AK; Russell IF; Birks RJ; Patrick MR
    Anaesthesia; 1997 Oct; 52(10):1005-11. PubMed ID: 9370847
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Postdural puncture headache: a randomized comparison of five spinal needles in obstetric patients.
    Vallejo MC; Mandell GL; Sabo DP; Ramanathan S
    Anesth Analg; 2000 Oct; 91(4):916-20. PubMed ID: 11004048
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Postdural puncture headache: a cross-sectional study of incidence and severity in a new obstetric anaesthesia unit.
    Imarengiaye C; Ekwere I
    Afr J Med Med Sci; 2006 Mar; 35(1):47-51. PubMed ID: 17209327
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An evaluation of a combined spinal/epidural needle set utilising a 26-gauge, pencil point spinal needle for caesarean section.
    Westbrook JL; Donald F; Carrie LE
    Anaesthesia; 1992 Nov; 47(11):990-2. PubMed ID: 1466446
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sprotte needle for intrathecal anaesthesia for caesarean section: incidence of postdural puncture headache.
    Cesarini M; Torrielli R; Lahaye F; Mene JM; Cabiro C
    Anaesthesia; 1990 Aug; 45(8):656-8. PubMed ID: 2400077
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Post-dural puncture headache following caesarean section in Nigerian parturients: A comparison of two spinal needles.
    Fyneface-Ogan S; Mato CN; Odagme MT
    Niger Postgrad Med J; 2006 Sep; 13(3):200-2. PubMed ID: 17066105
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Responses to dural puncture during institution of combined spinal-epidural analgesia: a comparison of 27 gauge pencil-point and 27 gauge cutting-edge needles.
    van den Berg AA; Ghatge S; Armendariz G; Cornelius D; Wang S
    Anaesth Intensive Care; 2011 Mar; 39(2):247-51. PubMed ID: 21485674
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spinal needle design and size affect the incidence of postdural puncture headache in children.
    Apiliogullari S; Duman A; Gok F; Akillioglu I
    Paediatr Anaesth; 2010 Feb; 20(2):177-82. PubMed ID: 20015139
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of 25-gauge, Quincke and Whitacre needles for postdural puncture headache in obstetric patients.
    Bano F; Haider S; Aftab S; Sultan ST
    J Coll Physicians Surg Pak; 2004 Nov; 14(11):647-50. PubMed ID: 15530271
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Post dural puncture headache in cesarean section: comparison of 25-gauge Whitacre with 25- and 26-gauge Quincke needles.
    Hwang JJ; Ho ST; Wang JJ; Liu HS
    Acta Anaesthesiol Sin; 1997 Mar; 35(1):33-7. PubMed ID: 9212479
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Postdural puncture headache and transient neurologic symptoms in children after spinal anaesthesia using cutting and pencil point paediatric spinal needles.
    Kokki H; Hendolin H; Turunen M
    Acta Anaesthesiol Scand; 1998 Oct; 42(9):1076-82. PubMed ID: 9809091
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of 25-gauge Quincke and 24-gauge Gertie Marx needles for spinal anaesthesia for caesarean section.
    Imarengiaye CO; Edomwonyi NP
    East Afr Med J; 2002 Jul; 79(7):379-81. PubMed ID: 12638834
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.