These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 26471141)

  • 1. In Vitro Testing of an Implantable Wireless Telemetry System for Long-Term Electromyography Recordings in Large Animals.
    Kneisz L; Unger E; Lanmüller H; Mayr W
    Artif Organs; 2015 Oct; 39(10):897-902. PubMed ID: 26471141
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantable multichannel wireless electromyography for prosthesis control.
    McDonnall D; Hiatt S; Smith C; Guillory KS
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():1350-3. PubMed ID: 23366149
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility of a Wireless Implantable Multi-electrode System for High-bandwidth Prosthetic Interfacing: Animal and Cadaver Study.
    Gstoettner C; Festin C; Prahm C; Bergmeister KD; Salminger S; Sturma A; Hofer C; Russold MF; Howard CL; McDonnall D; Farina D; Aszmann OC
    Clin Orthop Relat Res; 2022 Jun; 480(6):1191-1204. PubMed ID: 35202032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMG Acquisition Device.
    Ng KA; Rusly A; Gammad GGL; Le N; Liu SC; Leong KW; Zhang M; Ho JS; Yoo J; Yen SC
    IEEE Trans Biomed Circuits Syst; 2020 Aug; 14(4):889-902. PubMed ID: 32746357
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An implanted myoelectrically-controlled neuroprosthesis for upper extremity function in spinal cord injury.
    Kilgore KL; Hart RL; Montague FW; Bryden AM; Keith MW; Hoyen HA; Sams CJ; Peckham PH
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1630-3. PubMed ID: 17946056
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Implantable myoelectric sensors (IMESs) for intramuscular electromyogram recording.
    Weir RF; Troyk PR; DeMichele GA; Kerns DA; Schorsch JF; Maas H
    IEEE Trans Biomed Eng; 2009 Jan; 56(1):159-71. PubMed ID: 19224729
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A distributed, high-channel-count, implanted bidirectional system for restoration of somatosensation and myoelectric control.
    Lambrecht JM; Cady SR; Peterson EJ; Dunning JL; Dinsmoor DA; Pape F; Graczyk EL; Tyler DJ
    J Neural Eng; 2024 Jun; 21(3):. PubMed ID: 38861967
    [No Abstract]   [Full Text] [Related]  

  • 8. An optical telemetry system for underwater recording of electromyogram and neuronal activity from non-tethered crayfish.
    Tsuchida Y; Hama N; Takahata M
    J Neurosci Methods; 2004 Aug; 137(1):103-9. PubMed ID: 15196832
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A telemetry system to chronically record muscle activity in middle-sized animals.
    Langenbach GE; van Ruijven LJ; van Eijden TM
    J Neurosci Methods; 2002 Mar; 114(2):197-203. PubMed ID: 11856571
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term decoding of movement force and direction with a wireless myoelectric implant.
    Morel P; Ferrea E; Taghizadeh-Sarshouri B; Audí JM; Ruff R; Hoffmann KP; Lewis S; Russold M; Dietl H; Abu-Saleh L; Schroeder D; Krautschneider W; Meiners T; Gail A
    J Neural Eng; 2016 Feb; 13(1):016002. PubMed ID: 26643959
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A battery-free multichannel digital neural/EMG telemetry system for flying insects.
    Thomas SJ; Harrison RR; Leonardo A; Reynolds MS
    IEEE Trans Biomed Circuits Syst; 2012 Oct; 6(5):424-36. PubMed ID: 23853229
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of a bone-anchored device as a hard-wired conduit for transmitting EMG signals from implanted muscle electrodes.
    Al-Ajam Y; Lancashire H; Pendegrass C; Kang N; Dowling RP; Taylor SJ; Blunn G
    IEEE Trans Biomed Eng; 2013 Jun; 60(6):1654-9. PubMed ID: 23358938
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design and testing of an advanced implantable neuroprosthesis with myoelectric control.
    Hart RL; Bhadra N; Montague FW; Kilgore KL; Peckham PH
    IEEE Trans Neural Syst Rehabil Eng; 2011 Feb; 19(1):45-53. PubMed ID: 20876029
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wireless wearable controller for upper-limb neuroprosthesis.
    Wheeler CA; Peckham PH
    J Rehabil Res Dev; 2009; 46(2):243-56. PubMed ID: 19533538
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Instrumentation for ENG and EMG recordings in FES systems.
    Nikolić ZM; Popović DB; Stein RB; Kenwell Z
    IEEE Trans Biomed Eng; 1994 Jul; 41(7):703-6. PubMed ID: 7927392
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rechargeable wireless EMG sensor for prosthetic control.
    Lichter PA; Lange EH; Riehle TH; Anderson SM; Hedin DS
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():5074-6. PubMed ID: 21095801
    [TBL] [Abstract][Full Text] [Related]  

  • 17. First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction.
    Becerra-Fajardo L; Minguillon J; Krob MO; Rodrigues C; González-Sánchez M; Megía-García Á; Galán CR; Henares FG; Comerma A; Del-Ama AJ; Gil-Agudo A; Grandas F; Schneider-Ickert A; Barroso FO; Ivorra A
    J Neuroeng Rehabil; 2024 Jan; 21(1):4. PubMed ID: 38172975
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A wireless implantable multichannel microstimulating system-on-a-chip with modular architecture.
    Ghovanloo M; Najafi K
    IEEE Trans Neural Syst Rehabil Eng; 2007 Sep; 15(3):449-57. PubMed ID: 17894278
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A power and data link for a wireless-implanted neural recording system.
    Rush AD; Troyk PR
    IEEE Trans Biomed Eng; 2012 Nov; 59(11):3255-62. PubMed ID: 22922687
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prosthesis Control with an Implantable Multichannel Wireless Electromyography System for High-Level Amputees: A Large-Animal Study.
    Bergmeister KD; Hader M; Lewis S; Russold MF; Schiestl M; Manzano-Szalai K; Roche AD; Salminger S; Dietl H; Aszmann OC
    Plast Reconstr Surg; 2016 Jan; 137(1):153-162. PubMed ID: 26710019
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.