These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 26471425)

  • 41. Automatic modeling of knee joint motion for the virtual reality dynamic anatomy (VRDA) tool.
    Baillot Y; Rolland JP; Wright DL
    Stud Health Technol Inform; 1999; 62():30-5. PubMed ID: 10538376
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Error analysis of a system for measuring three-dimensional joint motion.
    Suntay WJ; Grood ES; Hefzy MS; Butler DL; Noyes FR
    J Biomech Eng; 1983 May; 105(2):127-35. PubMed ID: 6865354
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Accuracy verification of the photostereometric system KKN/1B developed for intraoperative measurement of knee movement immediately after total knee arthroplasty.
    Nishino K; Hayashi T; Suzuki Y; Koga Y; Omori G
    Front Med Biol Eng; 1999; 9(4):261-73. PubMed ID: 10718664
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Three-dimensional kinematics of the human knee with intracortical pin fixation.
    Ishii Y; Terajima K; Terashima S; Koga Y
    Clin Orthop Relat Res; 1997 Oct; (343):144-50. PubMed ID: 9345219
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Knee joint secondary motion accuracy improved by quaternion-based optimizer with bony landmark constraints.
    Wang H; Zheng NN
    J Biomech Eng; 2010 Dec; 132(12):124502. PubMed ID: 21142329
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Anterior cruciate ligament rupture translates the axes of motion within the knee.
    Mannel H; Marin F; Claes L; Dürselen L
    Clin Biomech (Bristol, Avon); 2004 Feb; 19(2):130-5. PubMed ID: 14967575
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Tibiofemoral joint contact forces and knee kinematics during squatting.
    Smith SM; Cockburn RA; Hemmerich A; Li RM; Wyss UP
    Gait Posture; 2008 Apr; 27(3):376-86. PubMed ID: 17583512
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Influence of joint constraints on lower limb kinematics estimation from skin markers using global optimization.
    Duprey S; Cheze L; Dumas R
    J Biomech; 2010 Oct; 43(14):2858-62. PubMed ID: 20701914
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Anterior translation and rotational stability of anterior cruciate ligament-deficient knees during walking: speed and turning direction.
    Yim JH; Seon JK; Kim YK; Jung ST; Shin CS; Yang DH; Rhym IS; Song EK
    J Orthop Sci; 2015 Jan; 20(1):155-62. PubMed ID: 25395272
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Development of a hinge compatible with the kinematics of the knee joint.
    Bertomeu JM; Lois JM; Guillem RB; Pozo AP; Lacuesta J; Mollà CG; Luna PV; Pastor JP
    Prosthet Orthot Int; 2007 Dec; 31(4):371-83. PubMed ID: 18050008
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Quantification of inertial sensor-based 3D joint angle measurement accuracy using an instrumented gimbal.
    Brennan A; Zhang J; Deluzio K; Li Q
    Gait Posture; 2011 Jul; 34(3):320-3. PubMed ID: 21715167
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Forces and moments in six-DOF at the human knee joint: mathematical description for control.
    Fujie H; Livesay GA; Fujita M; Woo SL
    J Biomech; 1996 Dec; 29(12):1577-85. PubMed ID: 8945656
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty.
    Uvehammer J
    Acta Orthop Scand Suppl; 2001 Feb; 72(299):1-52. PubMed ID: 11381581
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Accuracy of an electromagnetic measurement device and application to the measurement and description of knee joint motion.
    Bull AM; Berkshire FH; Amis AA
    Proc Inst Mech Eng H; 1998; 212(5):347-55. PubMed ID: 9803154
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Reproducibility measurements of three methods for calculating in vivo MR-based knee kinematics.
    Lansdown DA; Zaid M; Pedoia V; Subburaj K; Souza R; Benjamin C; Li X
    J Magn Reson Imaging; 2015 Aug; 42(2):533-8. PubMed ID: 25545617
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A constraint-based approach to modelling the mobility of the human knee joint.
    Feikes JD; O'Connor JJ; Zavatsky AB
    J Biomech; 2003 Jan; 36(1):125-9. PubMed ID: 12485647
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Functional calibration procedure for 3D knee joint angle description using inertial sensors.
    Favre J; Aissaoui R; Jolles BM; de Guise JA; Aminian K
    J Biomech; 2009 Oct; 42(14):2330-5. PubMed ID: 19665712
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A quantitative analysis of knee joint kinematics during the sidestep cutting maneuver. Implications for non-contact anterior cruciate ligament injury.
    McLean SG; Myers PT; Neal RJ; Walters MR
    Bull Hosp Jt Dis; 1998; 57(1):30-8. PubMed ID: 9553700
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Dynamic in vivo kinematics of the intact ovine stifle joint.
    Tapper JE; Fukushima S; Azuma H; Thornton GM; Ronsky JL; Shrive NG; Frank CB
    J Orthop Res; 2006 Apr; 24(4):782-92. PubMed ID: 16514638
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A model-based method for the reconstruction of total knee replacement kinematics.
    Zuffi S; Leardini A; Catani F; Fantozzi S; Cappello A
    IEEE Trans Med Imaging; 1999 Oct; 18(10):981-91. PubMed ID: 10628957
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.