  • 1. Lead Integrity Alert Is Useful for Assessment of Performance of Biotronik Linox Leads.
    Steinberg C; Padfield GJ; Hahn E; Flavelle S; McILROY C; VAN Bremen O; Yeung-Lai-Wah JA; Kerr CR; Deyell MW; Tung SK; Andrade JG; Bennett MT; Bashir JG; Krahn AD; Chakrabarti S
    J Cardiovasc Electrophysiol; 2015 Dec; 26(12):1340-5. PubMed ID: 26471861
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: a prospective study.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Sachanandani H; Ellenbogen KA
    Circulation; 2010 Oct; 122(15):1449-55. PubMed ID: 20876433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early failure of the Biotronik Linox implantable cardioverter defibrillator lead.
    Padfield GJ; Steinberg C; Karim SS; Tung S; Bennett MT; Le Maitre JP; Bashir J
    J Cardiovasc Electrophysiol; 2015 Mar; 26(3):274-81. PubMed ID: 25404263
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Failure rate and conductor externalization in the Biotronik Linox/Sorin Vigila implantable cardioverter-defibrillator lead.
    Noti F; Lam A; Klossner N; Seiler J; Servatius H; Medeiros-Domingo A; Nam Tran V; Haeberlin A; Fuhrer J; Tanner H; Roten L
    Heart Rhythm; 2016 May; 13(5):1075-1082. PubMed ID: 26738946
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures.
    Kallinen LM; Hauser RG; Tang C; Melby DP; Almquist AK; Katsiyiannis WT; Gornick CC
    Heart Rhythm; 2010 Aug; 7(8):1048-55. PubMed ID: 20493965
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of lead failure manifestation of Biotronik Linox with St. Jude Medical Riata and Medtronic Sprint Fidelis lead.
    Lam A; Buehler S; Goulouti E; Sweda R; Haeberlin A; Medeiros-Domingo A; Servatius H; Seiler J; Baldinger S; Noti F; Tanner H; Roten L
    J Interv Card Electrophysiol; 2019 Mar; 54(2):161-170. PubMed ID: 30471050
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-Term Evaluation of Biotronik Linox and Linox(smart) Implantable Cardioverter Defibrillator Leads.
    Good ED; Cakulev I; Orlov MV; Hirsh D; Simeles J; Mohr K; Moll P; Bloom H
    J Cardiovasc Electrophysiol; 2016 Jun; 27(6):735-42. PubMed ID: 26990515
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of longevity and clinical outcomes of implantable cardioverter-defibrillator leads among manufacturers.
    Kawada S; Nishii N; Morimoto Y; Miyoshi A; Tachibana M; Sugiyama H; Nakagawa K; Watanabe A; Morita H; Ito H
    Heart Rhythm; 2017 Oct; 14(10):1496-1503. PubMed ID: 28502870
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Insulation Failure of the Linox Defibrillator Lead: A Case Report and Retrospective Review of a Single Center Experience.
    Howe AJ; McKeag NA; Wilson CM; Ashfield KP; Roberts MJ
    J Cardiovasc Electrophysiol; 2015 Jun; 26(6):686-9. PubMed ID: 25711237
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative study of the failure rates among 3 implantable defibrillator leads.
    van Malderen SC; Szili-Torok T; Yap SC; Hoeks SE; Zijlstra F; Theuns DA
    Heart Rhythm; 2016 Dec; 13(12):2299-2305. PubMed ID: 27496586
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of the Linox implantable cardioverter defibrillator leads: A single-center experience.
    Marai I; Milman A; Nof E; Gurevitz O; Barlev D; Lipchenca I; Bachar S; Glikson M; Beinart R
    Pacing Clin Electrophysiol; 2019 Dec; 42(12):1524-1528. PubMed ID: 31602668
    [TBL] [Abstract][Full Text] [Related]  

  • 12. First time description of early lead failure of the Linox Smart lead compared to other contemporary high-voltage leads.
    Weberndörfer V; Nyffenegger T; Russi I; Brinkert M; Berte B; Toggweiler S; Kobza R
    J Interv Card Electrophysiol; 2018 Jul; 52(2):173-177. PubMed ID: 29713860
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of Lead Integrity Alert to assist in the clinical diagnosis of implantable cardioverter defibrillator lead failures: analysis of different implantable cardioverter defibrillator leads.
    Ellenbogen KA; Gunderson BD; Stromberg KD; Swerdlow CD
    Circ Arrhythm Electrophysiol; 2013 Dec; 6(6):1169-77. PubMed ID: 24099976
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of early failure of Biotronik Linox Smart implantable cardioverter-defibrillator leads: A comparative study of three defibrillator leads.
    Pérez Díez D; Rubín JM; Calvo Cuervo D; García Iglesias D; Morís De La Tassa C
    Pacing Clin Electrophysiol; 2018 Sep; 41(9):1165-1170. PubMed ID: 29894002
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prospective Assessment of Linox Implantable Cardioverter Defibrillator Leads for Structural or Electrical Abnormalities.
    McKeag NA; Noad RL; Ashfield K; Wilson CM; McEneaney DJ; Roberts MJD
    Adv Ther; 2018 May; 35(5):666-670. PubMed ID: 29730835
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An algorithm to predict implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA
    J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Patient Alert to detect ICD lead failure: efficacy, limitations, and implications for future algorithms.
    Vollmann D; Erdogan A; Himmrich E; Neuzner J; Becker D; Unterberg-Buchwald C; Sperzel J
    Europace; 2006 May; 8(5):371-6. PubMed ID: 16635998
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Long-term single-center comparison of ICD lead survival: Evidence for premature Linox lead failure.
    O'Connor M; Hooks D; Webber M; Shi B; Morrison S; Harding S; Larsen P
    J Cardiovasc Electrophysiol; 2018 Jul; 29(7):1024-1031. PubMed ID: 29656578
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of an implantable cardioverter-defibrillator lead family.
    Klampfleitner S; Mundel M; Schinke K; Neuberger HR
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):700-709. PubMed ID: 36640428
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]