These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 26477839)

  • 1. A scanning acoustic microscope discriminates cancer cells in fluid.
    Miura K; Yamamoto S
    Sci Rep; 2015 Oct; 5():15243. PubMed ID: 26477839
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulmonary imaging with a scanning acoustic microscope discriminates speed-of-sound and shows structural characteristics of disease.
    Miura K; Yamamoto S
    Lab Invest; 2012 Dec; 92(12):1760-5. PubMed ID: 23007131
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microscopic observation of chemical modification in sections using scanning acoustic microscopy.
    Miura K; Egawa Y; Moriki T; Mineta H; Harada H; Baba S; Yamamoto S
    Pathol Int; 2015 Jul; 65(7):355-66. PubMed ID: 25824722
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Acoustic Histology with Specific Dyes and Antibodies.
    Miura K; Yamashita K
    Ultrasound Med Biol; 2019 Dec; 45(12):3279-3289. PubMed ID: 31563478
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Observations of amyloid breakdown by proteases over time using scanning acoustic microscopy.
    Miura K; Iwashita T
    Sci Rep; 2023 Nov; 13(1):20642. PubMed ID: 38001251
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Scanning acoustic microscopy imaging of cellular structural and mechanical alterations from external stimuli.
    Miura K; Fukushi Y
    Heliyon; 2021 Aug; 7(8):e07847. PubMed ID: 34485733
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stiffness reduction and collagenase resistance of aging lungs measured using scanning acoustic microscopy.
    Miura K
    PLoS One; 2022; 17(2):e0263926. PubMed ID: 35176066
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Scanning acoustic microscopy for characterization of neoplastic and inflammatory lesions of lymph nodes.
    Miura K; Nasu H; Yamamoto S
    Sci Rep; 2013; 3():1255. PubMed ID: 23409246
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sound speed scanning acoustic microscopy for biomedical applications.
    Saijo Y; Sasaki H; Hozumi N; Kobayashi K; Tanaka M; Yambe T
    Technol Health Care; 2005; 13(4):261-7. PubMed ID: 16055974
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Material Properties of Human Ocular Tissue at 7-µm Resolution.
    Rohrbach D; Ito K; Lloyd HO; Silverman RH; Yoshida K; Yamaguchi T; Mamou J
    Ultrason Imaging; 2017 Sep; 39(5):313-325. PubMed ID: 28675987
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spatial distribution of anisotropic acoustic impedance assessed by time-resolved 50-MHz scanning acoustic microscopy and its relation to porosity in human cortical bone.
    Saïed A; Raum K; Leguerney I; Laugier P
    Bone; 2008 Jul; 43(1):187-194. PubMed ID: 18407822
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Novel flowcytometry-based approach of malignant cell detection in body fluids using an automated hematology analyzer.
    Ai T; Tabe Y; Takemura H; Kimura K; Takahashi T; Yang H; Tsuchiya K; Konishi A; Uchihashi K; Horii T; Ohsaka A
    PLoS One; 2018; 13(2):e0190886. PubMed ID: 29425230
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Speed of sound in diseased liver observed by scanning acoustic microscopy with 80 MHz and 250 MHz.
    Irie S; Inoue K; Yoshida K; Mamou J; Kobayashi K; Maruyama H; Yamaguchi T
    J Acoust Soc Am; 2016 Jan; 139(1):512-9. PubMed ID: 26827044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic value of clot examination for malignant cells in serous effusions.
    Jalal R; Aftab K; Hasan SH; Pervez S
    Cytopathology; 2009 Aug; 20(4):231-4. PubMed ID: 18627403
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of cytogenetic analysis of body fluids in cancer diagnosis.
    Izadian N
    J R Soc Med; 1982 Jun; 75(6):435-42. PubMed ID: 7086792
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the clinic microscopy laboratory with the cytopathology laboratory in the detection of malignant cells in body fluids.
    Ben-Ezra J; Stastny JF; Harris AC; Bork L; Frable WJ
    Am J Clin Pathol; 1994 Oct; 102(4):439-42. PubMed ID: 7942600
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Body fluid cellular analysis using the Sysmex XN-2000 automatic hematology analyzer: focusing on malignant samples.
    Cho YU; Chi HS; Park SH; Jang S; Kim YJ; Park CJ
    Int J Lab Hematol; 2015 Jun; 37(3):346-56. PubMed ID: 25212101
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does decalcification alter the tissue sound speed of rabbit supraspinatus tendon insertion? In vitro measurement using scanning acoustic microscopy.
    Sano H; Hattori K; Saijo Y; Kokubun S
    Ultrasonics; 2006 Jul; 44(3):297-301. PubMed ID: 16677677
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Scanning electron microscopy of body fluids.
    Beals TF
    Diagn Cytopathol; 1992; 8(3):266-71. PubMed ID: 1606884
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative investigation of elastic properties in a trabecula using micro-Brillouin scattering and scanning acoustic microscopy.
    Kawabe M; Fukui K; Matsukawa M; Granke M; Saïed A; Grimal Q; Laugier P
    J Acoust Soc Am; 2012 Jul; 132(1):EL54-60. PubMed ID: 22779573
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.