These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 26479506)

  • 1. Bayesian meta-analysis of test accuracy in the absence of a perfect reference test applied to bone scintigraphy for the diagnosis of complex regional pain syndrome.
    Held U; Brunner F; Steurer J; Wertli MM
    Biom J; 2015 Nov; 57(6):1020-37. PubMed ID: 26479506
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Usefulness of bone scintigraphy for the diagnosis of Complex Regional Pain Syndrome 1: A systematic review and Bayesian meta-analysis.
    Wertli MM; Brunner F; Steurer J; Held U
    PLoS One; 2017; 12(3):e0173688. PubMed ID: 28301606
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Concordance of qualitative bone scintigraphy results with presence of clinical complex regional pain syndrome 1: meta-analysis of test accuracy studies.
    Ringer R; Wertli M; Bachmann LM; Buck FM; Brunner F
    Eur J Pain; 2012 Nov; 16(10):1347-56. PubMed ID: 22473897
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sensitivity and specificity of 3-phase bone scintigraphy in the diagnosis of complex regional pain syndrome of the upper extremity.
    Wüppenhorst N; Maier C; Frettlöh J; Pennekamp W; Nicolas V
    Clin J Pain; 2010; 26(3):182-9. PubMed ID: 20173431
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A general framework for comparative Bayesian meta-analysis of diagnostic studies.
    Menten J; Lesaffre E
    BMC Med Res Methodol; 2015 Aug; 15():70. PubMed ID: 26315894
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Is there a correlation between symptoms and bone scintigraphic findings in patients with complex regional pain syndrome?
    AlSharif A; Akel AY; Sheikh-Ali RF; Juweid ME; Hawamdeh ZM; Ajlouni JM; Abdulsahib AS; AlHadidi FA; ElHadidy ST
    Ann Nucl Med; 2012 Oct; 26(8):665-9. PubMed ID: 22797817
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative evaluation of very acute stage of complex regional pain syndrome after stroke using three-phase bone scintigraphy.
    Park SG; Hyun JK; Lee SJ; Jeon JY
    Nucl Med Commun; 2007 Oct; 28(10):766-70. PubMed ID: 17728605
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A unification of models for meta-analysis of diagnostic accuracy studies without a gold standard.
    Liu Y; Chen Y; Chu H
    Biometrics; 2015 Jun; 71(2):538-47. PubMed ID: 25358907
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Meta-analysis of diagnostic test studies using individual patient data and aggregate data.
    Riley RD; Dodd SR; Craig JV; Thompson JR; Williamson PR
    Stat Med; 2008 Dec; 27(29):6111-36. PubMed ID: 18816508
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic accuracy of clinical illness for bovine respiratory disease (BRD) diagnosis in beef cattle placed in feedlots: A systematic literature review and hierarchical Bayesian latent-class meta-analysis.
    Timsit E; Dendukuri N; Schiller I; Buczinski S
    Prev Vet Med; 2016 Dec; 135():67-73. PubMed ID: 27931931
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Utility of Radionuclide Bone Scintigraphy in Complex Regional Pain Syndrome.
    Howard BA; Roy L; Kaye AD; Pyati S
    Curr Pain Headache Rep; 2018 Feb; 22(1):7. PubMed ID: 29388057
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bayesian meta-analysis of diagnostic tests allowing for imperfect reference standards.
    Menten J; Boelaert M; Lesaffre E
    Stat Med; 2013 Dec; 32(30):5398-413. PubMed ID: 24003003
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bayesian meta-analysis of the accuracy of a test for tuberculous pleuritis in the absence of a gold standard reference.
    Dendukuri N; Schiller I; Joseph L; Pai M
    Biometrics; 2012 Dec; 68(4):1285-93. PubMed ID: 22568612
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Meta-analysis of diagnostic test accuracy assessment studies with varying number of thresholds.
    Dukic V; Gatsonis C
    Biometrics; 2003 Dec; 59(4):936-46. PubMed ID: 14969472
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Complex Regional Pain Syndrome type I with atypical scintigraphic pattern--diagnosis and evaluation of the entity with three phase bone scintigraphy. A case report.
    Pachowicz M; Nocuń A; Postępski J; Olesińska E; Emeryk A; Chrapko B
    Nucl Med Rev Cent East Eur; 2014; 17(2):115-9. PubMed ID: 25088114
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluating the accuracy and economic value of a new test in the absence of a perfect reference test.
    Xie X; Sinclair A; Dendukuri N
    Res Synth Methods; 2017 Sep; 8(3):321-332. PubMed ID: 28544646
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Bayesian approach to simultaneously adjusting for verification and reference standard bias in diagnostic test studies.
    Lu Y; Dendukuri N; Schiller I; Joseph L
    Stat Med; 2010 Oct; 29(24):2532-43. PubMed ID: 20799249
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Estimation of diagnostic accuracy of a combination of continuous biomarkers allowing for conditional dependence between the biomarkers and the imperfect reference-test.
    García Barrado L; Coart E; Burzykowski T
    Biometrics; 2017 Jun; 73(2):646-655. PubMed ID: 27598904
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Empirical Bayes estimates generated in a hierarchical summary ROC analysis agreed closely with those of a full Bayesian analysis.
    Macaskill P
    J Clin Epidemiol; 2004 Sep; 57(9):925-32. PubMed ID: 15504635
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bayesian bivariate meta-analysis of sensitivity and specificity: summary of quantitative findings in 50 meta-analyses.
    Menke J
    J Eval Clin Pract; 2014 Dec; 20(6):844-52. PubMed ID: 24828853
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.