These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

311 related articles for article (PubMed ID: 26480879)

  • 1. Is minimally invasive plating osteosynthesis for humeral shaft fracture advantageous compared with the conventional open technique?
    Wang C; Li J; Li Y; Dai G; Wang M
    J Shoulder Elbow Surg; 2015 Nov; 24(11):1741-8. PubMed ID: 26480879
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [A comparative study on open reduction and plating osteosynthesis and minimal invasive plating osteosynthesis in treating mid-distal humeral shaft fractures].
    An Z; He X; Zeng B
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Jan; 23(1):41-4. PubMed ID: 19192876
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.
    Kim JW; Oh CW; Byun YS; Kim JJ; Park KC
    J Orthop Trauma; 2015 Apr; 29(4):189-94. PubMed ID: 25210833
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures.
    Ko SH; Cha JR; Lee CC; Joo YT; Eom KS
    Clin Orthop Surg; 2017 Dec; 9(4):506-513. PubMed ID: 29201304
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Plating of humeral shaft fractures: comparison of standard conventional plating versus minimally invasive plating.
    Oh CW; Byun YS; Oh JK; Kim JJ; Jeon IH; Lee JH; Park KH
    Orthop Traumatol Surg Res; 2012 Feb; 98(1):54-60. PubMed ID: 22204793
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis.
    Hu X; Xu S; Lu H; Chen B; Zhou X; He X; Dai J; Zhang Z; Gong S
    J Orthop Surg Res; 2016 May; 11(1):59. PubMed ID: 27169580
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
    Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
    BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical comparison between open plating and minimally invasive plate osteosynthesis for displaced proximal humeral fractures: A prospective randomized controlled trial.
    Sohn HS; Jeon YS; Lee J; Shin SJ
    Injury; 2017 Jun; 48(6):1175-1182. PubMed ID: 28372791
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.
    Sohn HS; Kim WJ; Shon MS
    Injury; 2015 Aug; 46(8):1577-84. PubMed ID: 26077663
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessing functional and radiological outcomes: open reduction and internal fixation vs. minimally invasive plate osteosynthesis for humerus shaft fractures - a prospective comparative study.
    Sugumar N; Sathiyaseelan N; Purushothaman JR; Natarajan S
    Int Orthop; 2024 Nov; 48(11):2979-2991. PubMed ID: 39285022
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Anterior medial minimally invasive plate osteosynthesis for humeral shaft fractures shows superior early shoulder and elbow function compared to locking compression plate: A retrospective study.
    Yang Z; Ouyang B; Yang J; Liu D; Kang X
    Injury; 2024 Aug; 55(8):111692. PubMed ID: 38945080
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Effectiveness comparison of two minimally invasive plate osteosynthesis techniques for proximal humeral shaft fractures].
    Wang X; Sun K; Tang L; Liang B; Yin D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Feb; 37(2):147-152. PubMed ID: 36796807
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures.
    Zhiquan A; Bingfang Z; Yeming W; Chi Z; Peiyan H
    J Orthop Trauma; 2007 Oct; 21(9):628-33. PubMed ID: 17921838
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Treatment of humeral shaft fractures: a new minimally-invasive plate osteosynthesis versus open reduction and internal fixation: a case control study.
    Yang J; Liu D; Zhang L; Lu Z; Liu T; Tao C
    BMC Surg; 2021 Sep; 21(1):349. PubMed ID: 34551734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between osteosynthesis with interlocking nail and minimally invasive plating for proximal- and middle-thirds of humeral shaft fractures.
    Wang Y; Chen H; Wang L; Chen X; Zhi X; Cui J; Cao L
    Int Orthop; 2021 Aug; 45(8):2093-2102. PubMed ID: 33184684
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rotational evaluation of humeral shaft fractures with proximal extension fixed using the MIPO technique.
    Zamboni C; Durigan JR; Pimentel FD; Hungria JOS; Mercadante MT; de Moraes Barros Fucs PM
    Injury; 2018 Aug; 49(8):1558-1561. PubMed ID: 30041984
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.
    Shin SJ; Sohn HS; Do NH
    J Orthop Trauma; 2012 Oct; 26(10):585-9. PubMed ID: 22534690
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Postoperative malrotation of humeral shaft fracture after plating compared with intramedullary nailing.
    Li Y; Wang C; Wang M; Huang L; Huang Q
    J Shoulder Elbow Surg; 2011 Sep; 20(6):947-54. PubMed ID: 21440461
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Absolute or relative stability in plate fixation for simple humeral shaft fractures.
    van de Wall BJM; Theus C; Link BC; van Veelen N; van de Leeuwen RJH; Ganzert C; Babst R; Beeres FJP
    Injury; 2019 Nov; 50(11):1986-1991. PubMed ID: 31431330
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Early Results of Bridge Plating of Humerus Diaphyseal Fractures by MIPO Technique.
    Mehraj M; Shah I; Mohd J; Rasool S
    Ortop Traumatol Rehabil; 2019 Apr; 21(2):117-121. PubMed ID: 31180033
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.