311 related articles for article (PubMed ID: 26480879)
1. Is minimally invasive plating osteosynthesis for humeral shaft fracture advantageous compared with the conventional open technique?
Wang C; Li J; Li Y; Dai G; Wang M
J Shoulder Elbow Surg; 2015 Nov; 24(11):1741-8. PubMed ID: 26480879
[TBL] [Abstract][Full Text] [Related]
2. [A comparative study on open reduction and plating osteosynthesis and minimal invasive plating osteosynthesis in treating mid-distal humeral shaft fractures].
An Z; He X; Zeng B
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Jan; 23(1):41-4. PubMed ID: 19192876
[TBL] [Abstract][Full Text] [Related]
3. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.
Kim JW; Oh CW; Byun YS; Kim JJ; Park KC
J Orthop Trauma; 2015 Apr; 29(4):189-94. PubMed ID: 25210833
[TBL] [Abstract][Full Text] [Related]
4. Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures.
Ko SH; Cha JR; Lee CC; Joo YT; Eom KS
Clin Orthop Surg; 2017 Dec; 9(4):506-513. PubMed ID: 29201304
[TBL] [Abstract][Full Text] [Related]
5. Plating of humeral shaft fractures: comparison of standard conventional plating versus minimally invasive plating.
Oh CW; Byun YS; Oh JK; Kim JJ; Jeon IH; Lee JH; Park KH
Orthop Traumatol Surg Res; 2012 Feb; 98(1):54-60. PubMed ID: 22204793
[TBL] [Abstract][Full Text] [Related]
6. Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis.
Hu X; Xu S; Lu H; Chen B; Zhou X; He X; Dai J; Zhang Z; Gong S
J Orthop Surg Res; 2016 May; 11(1):59. PubMed ID: 27169580
[TBL] [Abstract][Full Text] [Related]
7. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
[TBL] [Abstract][Full Text] [Related]
8. Clinical comparison between open plating and minimally invasive plate osteosynthesis for displaced proximal humeral fractures: A prospective randomized controlled trial.
Sohn HS; Jeon YS; Lee J; Shin SJ
Injury; 2017 Jun; 48(6):1175-1182. PubMed ID: 28372791
[TBL] [Abstract][Full Text] [Related]
9. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.
Sohn HS; Kim WJ; Shon MS
Injury; 2015 Aug; 46(8):1577-84. PubMed ID: 26077663
[TBL] [Abstract][Full Text] [Related]
10. [Effectiveness comparison of two minimally invasive plate osteosynthesis techniques for proximal humeral shaft fractures].
Wang X; Sun K; Tang L; Liang B; Yin D
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Feb; 37(2):147-152. PubMed ID: 36796807
[TBL] [Abstract][Full Text] [Related]
11. Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures.
Zhiquan A; Bingfang Z; Yeming W; Chi Z; Peiyan H
J Orthop Trauma; 2007 Oct; 21(9):628-33. PubMed ID: 17921838
[TBL] [Abstract][Full Text] [Related]
12. Treatment of humeral shaft fractures: a new minimally-invasive plate osteosynthesis versus open reduction and internal fixation: a case control study.
Yang J; Liu D; Zhang L; Lu Z; Liu T; Tao C
BMC Surg; 2021 Sep; 21(1):349. PubMed ID: 34551734
[TBL] [Abstract][Full Text] [Related]
13. Comparison between osteosynthesis with interlocking nail and minimally invasive plating for proximal- and middle-thirds of humeral shaft fractures.
Wang Y; Chen H; Wang L; Chen X; Zhi X; Cui J; Cao L
Int Orthop; 2021 Aug; 45(8):2093-2102. PubMed ID: 33184684
[TBL] [Abstract][Full Text] [Related]
14. Rotational evaluation of humeral shaft fractures with proximal extension fixed using the MIPO technique.
Zamboni C; Durigan JR; Pimentel FD; Hungria JOS; Mercadante MT; de Moraes Barros Fucs PM
Injury; 2018 Aug; 49(8):1558-1561. PubMed ID: 30041984
[TBL] [Abstract][Full Text] [Related]
15. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.
Shin SJ; Sohn HS; Do NH
J Orthop Trauma; 2012 Oct; 26(10):585-9. PubMed ID: 22534690
[TBL] [Abstract][Full Text] [Related]
16. Postoperative malrotation of humeral shaft fracture after plating compared with intramedullary nailing.
Li Y; Wang C; Wang M; Huang L; Huang Q
J Shoulder Elbow Surg; 2011 Sep; 20(6):947-54. PubMed ID: 21440461
[TBL] [Abstract][Full Text] [Related]
17. Absolute or relative stability in plate fixation for simple humeral shaft fractures.
van de Wall BJM; Theus C; Link BC; van Veelen N; van de Leeuwen RJH; Ganzert C; Babst R; Beeres FJP
Injury; 2019 Nov; 50(11):1986-1991. PubMed ID: 31431330
[TBL] [Abstract][Full Text] [Related]
18. Early Results of Bridge Plating of Humerus Diaphyseal Fractures by MIPO Technique.
Mehraj M; Shah I; Mohd J; Rasool S
Ortop Traumatol Rehabil; 2019 Apr; 21(2):117-121. PubMed ID: 31180033
[TBL] [Abstract][Full Text] [Related]
19. Anterior Minimally Invasive Plate Osteosynthesis for Humeral Shaft Fractures Is Safer Than Open Reduction Internal Fixation: A Matched Case-Controlled Comparison.
Randell M; Glatt V; Stabler A; Bussoletti T; Hohmann E; Tetsworth K
J Orthop Trauma; 2021 Aug; 35(8):424-429. PubMed ID: 33252449
[TBL] [Abstract][Full Text] [Related]
20. Interventions for humeral shaft fractures: mixed treatment comparisons of clinical trials.
Zhao Y; Wang J; Yao W; Cai Q; Wang Y; Yuan W; Gao S
Osteoporos Int; 2017 Nov; 28(11):3229-3237. PubMed ID: 28780727
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]