202 related articles for article (PubMed ID: 26483128)
1. Performance of glycated hemoglobin (HbA(1c)) methods evaluated with EQAS studies using fresh blood samples: Still space for improvements.
Mosca A; Paleari R; Carobene A; Weykamp C; Ceriotti F
Clin Chim Acta; 2015 Dec; 451(Pt B):305-9. PubMed ID: 26483128
[TBL] [Abstract][Full Text] [Related]
2. One in five laboratories using various hemoglobin A1c methods do not meet the criteria for optimal diabetes care management.
Lenters-Westra E; Weykamp C; Schindhelm RK; Siebelder C; Bilo HJ; Slingerland RJ
Diabetes Technol Ther; 2011 Apr; 13(4):429-33. PubMed ID: 21355726
[TBL] [Abstract][Full Text] [Related]
3. Comparison of IFCC-calibrated HbA(1c) from laboratory and point of care testing systems.
Manley SE; Hikin LJ; Round RA; Manning PW; Luzio SD; Dunseath GJ; Nightingale PG; Stratton IM; Cramb R; Sikaris KA; Gough SC; Webber J
Diabetes Res Clin Pract; 2014 Sep; 105(3):364-72. PubMed ID: 24985893
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the Sebia CAPILLARYS 2 flex piercing for the measurement of HbA(1c) on venous and capillary blood samples.
Heylen O; Van Neyghem S; Exterbille S; Wehlou C; Gorus F; Weets I
Am J Clin Pathol; 2014 Jun; 141(6):867-77. PubMed ID: 24838332
[TBL] [Abstract][Full Text] [Related]
5. Standardization and analytical goals for glycated hemoglobin measurement.
Braga F; Panteghini M
Clin Chem Lab Med; 2013 Sep; 51(9):1719-26. PubMed ID: 23729573
[TBL] [Abstract][Full Text] [Related]
6. Hb variants in Korea: effect on HbA1c using five routine methods.
Yun YM; Ji M; Ko DH; Chun S; Kwon GC; Lee K; Song SH; Seong MW; Park SS; Song J
Clin Chem Lab Med; 2017 Jul; 55(8):1234-1242. PubMed ID: 28107170
[TBL] [Abstract][Full Text] [Related]
7. Trueness assessment of HbA1c routine assays: are processed EQA materials up to the job?
Delatour V; Clouet-Foraison N; Jaisson S; Kaiser P; Gillery P
Clin Chem Lab Med; 2019 Sep; 57(10):1623-1631. PubMed ID: 31085744
[TBL] [Abstract][Full Text] [Related]
8. Best use of the recommended IFCC reference method, material and values in HbA1C analyses.
Penttilä IM; Halonen T; Punnonen K; Tiikkainen U
Scand J Clin Lab Invest; 2005; 65(6):453-62. PubMed ID: 16179278
[TBL] [Abstract][Full Text] [Related]
9. Analytical performance evaluation of the Norudia HbA
Lee JH; Kim S; Jun SH; Seo JD; Nam Y; Song SH; Lee K; Song J
J Clin Lab Anal; 2020 Nov; 34(11):e23504. PubMed ID: 33463769
[TBL] [Abstract][Full Text] [Related]
10. Glycated haemoglobin assays. Approaches to standardization of results.
Stott A; Casson IF; Higgins GJ
Diabet Med; 2001 Apr; 18(4):274-9. PubMed ID: 11437857
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the Sebia Capillarys 3 Tera and the Bio-Rad D-100 Systems for the Measurement of Hemoglobin A1c.
Herpol M; Lanckmans K; Van Neyghem S; Clement P; Crevits S; De Crem K; Gorus FK; Weets I
Am J Clin Pathol; 2016 Jul; 146(1):67-77. PubMed ID: 27357293
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the Menarini/ARKRAY ADAMS A1c HA-8180V analyser for HbA1c.
Weykamp C; Lenters-Westra E; van der Vuurst H; Slingerland R; Siebelder C; Visser-Dekkers W
Clin Chem Lab Med; 2011 Apr; 49(4):647-51. PubMed ID: 21323625
[TBL] [Abstract][Full Text] [Related]
13. Improvement in the Quality of HbA1c Determination by Using Commutable Specimens With IFCC-Assigned Values.
Zhou R; Gao ZQ; Tong Q; Zuo C; Song ZX; Wang W; Wang QT
Lab Med; 2017 May; 48(2):148-153. PubMed ID: 28371852
[TBL] [Abstract][Full Text] [Related]
14. IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study.
Hoelzel W; Weykamp C; Jeppsson JO; Miedema K; Barr JR; Goodall I; Hoshino T; John WG; Kobold U; Little R; Mosca A; Mauri P; Paroni R; Susanto F; Takei I; Thienpont L; Umemoto M; Wiedmeyer HM;
Clin Chem; 2004 Jan; 50(1):166-74. PubMed ID: 14709644
[TBL] [Abstract][Full Text] [Related]
15. Standardization of two immunological HbA1c routine assays according to the new IFCC reference method.
Groche D; Hoeno W; Hoss G; Vogt B; Herrmann Z; Witzigmann A
Clin Lab; 2003; 49(11-12):657-61. PubMed ID: 14651337
[TBL] [Abstract][Full Text] [Related]
16. Analytical performances of the D-100TM hemoglobin testing system (Bio-Rad) for HbA1c assay.
Jaisson S; Leroy N; Guillard E; Desmons A; Gillery P
Clin Chem Lab Med; 2015 Aug; 53(9):1473-9. PubMed ID: 26011926
[TBL] [Abstract][Full Text] [Related]
17. [Comparison of HbA1c analyzers: D-10, Variant II Turbo, Cobas Integra 800, and Afinion AS100].
Lee JY; Hong KS; Cho SE
Korean J Lab Med; 2010 Aug; 30(4):345-50. PubMed ID: 20805705
[TBL] [Abstract][Full Text] [Related]
18. Performance evaluation of HbA1c measurement systems with sigma metric for 1066 laboratories in China.
Huang Y; Zhang T; Zhao H; Wang W; Zhang C; He F; Zhong K; Yuan S; Du Y; Wang Z
Clin Chim Acta; 2018 Dec; 487():281-286. PubMed ID: 30312599
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of a next generation direct whole blood enzymatic assay for hemoglobin A1c on the ARCHITECT c8000 chemistry system.
Teodoro-Morrison T; Janssen MJ; Mols J; Hendrickx BH; Velmans MH; Lotz J; Lackner K; Lennartz L; Armbruster D; Maine G; Yip PM
Clin Chem Lab Med; 2015 Jan; 53(1):125-32. PubMed ID: 25153395
[TBL] [Abstract][Full Text] [Related]
20. Japanese standard reference material for JDS Lot 2 haemoglobin A1c. I: Comparison of Japan Diabetes Society-assigned values to those obtained by the Japanese and USA domestic standardization programmes and by the International Federation of Clinical Chemistry reference laboratories.
Tominaga M; Makino H; Yoshino G; Kuwa K; Takei I; Aono Y; Hoshino T; Umemoto M; Shimatsu A; Sanke T; Kuwashima M; Taminato T; Ono J
Ann Clin Biochem; 2005 Jan; 42(Pt 1):41-6. PubMed ID: 15802031
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]