These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2412 related articles for article (PubMed ID: 26491091)
21. Comparing endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) versus fine needle biopsy (FNB) in the diagnosis of solid lesions: study protocol for a randomized controlled trial. Wang J; Wu X; Yin P; Guo Q; Hou W; Li Y; Wang Y; Cheng B Trials; 2016 Apr; 17():198. PubMed ID: 27071386 [TBL] [Abstract][Full Text] [Related]
22. Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses. Nakai Y; Isayama H; Chang KJ; Yamamoto N; Hamada T; Uchino R; Mizuno S; Miyabayashi K; Yamamoto K; Kawakubo K; Kogure H; Sasaki T; Hirano K; Tanaka M; Tada M; Fukayama M; Koike K Dig Dis Sci; 2014 Jul; 59(7):1578-85. PubMed ID: 24429514 [TBL] [Abstract][Full Text] [Related]
23. Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) in insulinomas: Indications and clinical relevance in a single investigator cohort of 47 patients. Kann PH; Moll R; Bartsch D; Pfützner A; Forst T; Tamagno G; Goebel JN; Fourkiotis V; Bergmann SR; Collienne M Endocrine; 2017 Apr; 56(1):158-163. PubMed ID: 27905047 [TBL] [Abstract][Full Text] [Related]
24. Comparison of the diagnostic performance of 2 core biopsy needles for EUS-guided tissue acquisition from solid pancreatic lesions. Nayar MK; Paranandi B; Dawwas MF; Leeds JS; Darne A; Haugk B; Majumdar D; Ahmed MM; Oppong KW Gastrointest Endosc; 2017 May; 85(5):1017-1024. PubMed ID: 27633157 [TBL] [Abstract][Full Text] [Related]
25. A multicenter randomized trial comparing a 25-gauge EUS fine-needle aspiration device with a 20-gauge EUS fine-needle biopsy device. van Riet PA; Larghi A; Attili F; Rindi G; Nguyen NQ; Ruszkiewicz A; Kitano M; Chikugo T; Aslanian H; Farrell J; Robert M; Adeniran A; Van Der Merwe S; Roskams T; Chang K; Lin F; Lee JG; Arcidiacono PG; Petrone M; Doglioni C; Iglesias-Garcia J; Abdulkader I; Giovannini M; Bories E; Poizat F; Santo E; Scapa E; Marmor S; Bucobo JC; Buscaglia JM; Heimann A; Wu M; Baldaque-Silva F; Moro CF; Erler NS; Biermann K; Poley JW; Cahen DL; Bruno MJ Gastrointest Endosc; 2019 Feb; 89(2):329-339. PubMed ID: 30367877 [TBL] [Abstract][Full Text] [Related]
26. High-resolution endoscopic ultrasound imaging and the number of needle passages are significant factors predicting high yield of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid masses without an on-site cytopathologist. Jeong SH; Yoon HH; Kim EJ; Kim YJ; Kim YS; Cho JH Medicine (Baltimore); 2017 Jan; 96(2):e5782. PubMed ID: 28079803 [TBL] [Abstract][Full Text] [Related]
27. CT-guided biopsy of lesions of the lung, liver, pancreas or of enlarged lymph nodes: value of additional fine needle aspiration (FNA) to core needle biopsy (CNB) in an offsite pathologist setting. Schoellnast H; Komatz G; Bisail H; Talakic E; Fauster M; Ehammer T; Quehenberger F; Schaffler GJ Acad Radiol; 2010 Oct; 17(10):1275-81. PubMed ID: 20621527 [TBL] [Abstract][Full Text] [Related]
28. Impact of EUS-guided fine-needle biopsy sampling with a new core needle on the need for onsite cytopathologic assessment: a preliminary study. Rodrigues-Pinto E; Jalaj S; Grimm IS; Baron TH Gastrointest Endosc; 2016 Dec; 84(6):1040-1046. PubMed ID: 27345131 [TBL] [Abstract][Full Text] [Related]
29. Usefulness of endoscopic ultrasound-guided sampling using core biopsy needle as a percutaneous biopsy rescue for diagnosis of solid liver mass: Combined histological-cytological analysis. Lee YN; Moon JH; Kim HK; Choi HJ; Choi MH; Kim DC; Lee TH; Lee TH; Cha SW; Kim SG; Kim YS J Gastroenterol Hepatol; 2015 Jul; 30(7):1161-6. PubMed ID: 25684303 [TBL] [Abstract][Full Text] [Related]
30. Direct Comparison of Elastography Endoscopic Ultrasound Fine-Needle Aspiration and B-Mode Endoscopic Ultrasound Fine-Needle Aspiration in Diagnosing Solid Pancreatic Lesions. Gheorghiu M; Sparchez Z; Rusu I; Bolboacă SD; Seicean R; Pojoga C; Seicean A Int J Environ Res Public Health; 2022 Jan; 19(3):. PubMed ID: 35162325 [TBL] [Abstract][Full Text] [Related]
31. A Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Fine-Needle Biopsy in the Diagnosis of Solid Pancreatic Lesions. Ayres LR; Kmiotek EK; Lam E; Telford JJ Can J Gastroenterol Hepatol; 2018; 2018():1415062. PubMed ID: 29850451 [TBL] [Abstract][Full Text] [Related]
32. Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions. Berzosa M; Villa N; El-Serag HB; Sejpal DV; Patel KK Endosc Ultrasound; 2015; 4(1):28-33. PubMed ID: 25789281 [TBL] [Abstract][Full Text] [Related]
33. Efficacy of ultrasound-guided core needle gun biopsy in diagnosing cervical lymphadenopathy. Oh KH; Woo JS; Cho JG; Baek SK; Jung KY; Kwon SY Eur Ann Otorhinolaryngol Head Neck Dis; 2016 Dec; 133(6):401-404. PubMed ID: 27592165 [TBL] [Abstract][Full Text] [Related]
34. The usefulness of endoscopic ultrasound-guided fine-needle aspiration for the diagnosis of pancreatic neuroendocrine tumors based on the World Health Organization classification. Unno J; Kanno A; Masamune A; Kasajima A; Fujishima F; Ishida K; Hamada S; Kume K; Kikuta K; Hirota M; Motoi F; Unno M; Shimosegawa T Scand J Gastroenterol; 2014 Nov; 49(11):1367-74. PubMed ID: 25180490 [TBL] [Abstract][Full Text] [Related]
35. Per-Pass Performance Characteristics of Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Malignant Solid Pancreatic Masses in a Large Multicenter Cohort. Ge PS; Wani S; Watson RR; Sedarat A; Kim S; Marshall C; Wilson RH; Makker J; Mohamadnejad M; Komanduri S; Muthusamy VR Pancreas; 2018 Mar; 47(3):296-301. PubMed ID: 29401169 [TBL] [Abstract][Full Text] [Related]
36. Diagnostic ability and factors affecting accuracy of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid lesions: Japanese large single center experience. Haba S; Yamao K; Bhatia V; Mizuno N; Hara K; Hijioka S; Imaoka H; Niwa Y; Tajika M; Kondo S; Tanaka T; Shimizu Y; Yatabe Y; Hosoda W; Kawakami H; Sakamoto N J Gastroenterol; 2013 Aug; 48(8):973-81. PubMed ID: 23090002 [TBL] [Abstract][Full Text] [Related]
37. Comparison of the Diagnostic Yield of the Standard 22-Gauge Needle and the New 20-Gauge Forward-Bevel Core Biopsy Needle for Endoscopic Ultrasound-Guided Tissue Acquisition from Pancreatic Lesions. Fujie S; Ishiwatari H; Sasaki K; Sato J; Matsubayashi H; Yoshida M; Ito S; Kawata N; Imai K; Kakushima N; Takizawa K; Hotta K; Ono H Gut Liver; 2019 May; 13(3):349-355. PubMed ID: 30600677 [TBL] [Abstract][Full Text] [Related]
38. The clinical impact of immediate on-site cytopathology evaluation during endoscopic ultrasound-guided fine needle aspiration of pancreatic masses: a prospective multicenter randomized controlled trial. Wani S; Mullady D; Early DS; Rastogi A; Collins B; Wang JF; Marshall C; Sams SB; Yen R; Rizeq M; Romanas M; Ulusarac O; Brauer B; Attwell A; Gaddam S; Hollander TG; Hosford L; Johnson S; Kushnir V; Amateau SK; Kohlmeier C; Azar RR; Vargo J; Fukami N; Shah RJ; Das A; Edmundowicz SA Am J Gastroenterol; 2015 Oct; 110(10):1429-39. PubMed ID: 26346868 [TBL] [Abstract][Full Text] [Related]
39. Endoscopic ultrasound-guided tissue sampling by combined fine needle aspiration and trucut needle biopsy: a prospective study. Wittmann J; Kocjan G; Sgouros SN; Deheragoda M; Pereira SP Cytopathology; 2006 Feb; 17(1):27-33. PubMed ID: 16417562 [TBL] [Abstract][Full Text] [Related]
40. Slow-pull and different conventional suction techniques in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid lesions using 22-gauge needles. Chen JY; Ding QY; Lv Y; Guo W; Zhi FC; Liu SD; Cheng TM World J Gastroenterol; 2016 Oct; 22(39):8790-8797. PubMed ID: 27818594 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]