These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 2649229)

  • 1. Radiological image compression using full-frame cosine transform with adaptive bit-allocation.
    Chan KK; Lou SL; Huang HK
    Comput Med Imaging Graph; 1989; 13(2):153-9. PubMed ID: 2649229
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiological image compression: full-frame bit-allocation technique.
    Lo SC; Huang HK
    Radiology; 1985 Jun; 155(3):811-7. PubMed ID: 4001382
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiological image compression using error-free irreversible two-dimensional direct-cosine-transform coding techniques.
    Huang HK; Lo SC; Ho BK; Lou SL
    J Opt Soc Am A; 1987 May; 4(5):984-92. PubMed ID: 3598750
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A method for splitting digital value in radiological image compression.
    Lo SC; Shen EL; Mun SK; Chen J
    Med Phys; 1991; 18(5):939-46. PubMed ID: 1961158
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of irreversible image compression on diagnostic accuracy in thoracic imaging.
    Aberle DR; Gleeson F; Sayre JW; Brown K; Batra P; Young DA; Stewart BK; Ho BK; Huang HK
    Invest Radiol; 1993 May; 28(5):398-403. PubMed ID: 8496031
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Subperiosteal resorption: effect of full-frame image compression of hand radiographs on diagnostic accuracy.
    Sayre JW; Ho BK; Boechat MI; Hall TR; Huang HK
    Radiology; 1992 Nov; 185(2):599-603. PubMed ID: 1410380
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design and implementation of full-frame, bit-allocation image-compression hardware module. Work in progress.
    Ho BK; Chao J; Zhu P; Huang HK
    Radiology; 1991 May; 179(2):563-7. PubMed ID: 2014312
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Image data compression using a new floating-point digital signal processor.
    Siegel EL; Templeton AW; Hensley KL; McFadden MA; Baxter KG; Murphey MD; Cronin PE; Gesell RG; Dwyer SJ
    J Digit Imaging; 1991 Aug; 4(3):188-95. PubMed ID: 1911978
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Data compression: effect on diagnostic accuracy in digital chest radiography.
    MacMahon H; Doi K; Sanada S; Montner SM; Giger ML; Metz CE; Nakamori N; Yin FF; Xu XW; Yonekawa H
    Radiology; 1991 Jan; 178(1):175-9. PubMed ID: 1984299
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical evaluation of irreversible image compression: analysis of chest imaging with computed radiography.
    Ishigaki T; Sakuma S; Ikeda M; Itoh Y; Suzuki M; Iwai S
    Radiology; 1990 Jun; 175(3):739-43. PubMed ID: 2343125
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Medical image compression by discrete cosine transform spectral similarity strategy.
    Wu YG; Tai SC
    IEEE Trans Inf Technol Biomed; 2001 Sep; 5(3):236-43. PubMed ID: 11550845
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved contralateral subtraction images by use of elastic matching technique.
    Li Q; Katsuragawa S; Doi K
    Med Phys; 2000 Aug; 27(8):1934-42. PubMed ID: 10984239
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Full-frame transform compression of CT and MR images.
    Chan KK; Lou SL; Huang HK
    Radiology; 1989 Jun; 171(3):847-51. PubMed ID: 2717763
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Compression of radiological images with 512, 1,024, and 2,048 matrices.
    Lo SC; Huang HK
    Radiology; 1986 Nov; 161(2):519-25. PubMed ID: 3763925
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiography.
    Katsuragawa S; Tagashira H; Li Q; MacMahon H; Doi K
    J Digit Imaging; 1999 Nov; 12(4):166-72. PubMed ID: 10587911
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effects of lossy compression on the detection of subtle pulmonary nodules.
    Cox GG; Cook LT; Insana MF; McFadden MA; Hall TJ; Harrison LA; Eckard DA; Martin NL
    Med Phys; 1996 Jan; 23(1):127-32. PubMed ID: 8700023
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Medical image compression based on a morphological representation of wavelet coefficients.
    Phelan NC; Ennis JT
    Med Phys; 1999 Aug; 26(8):1607-11. PubMed ID: 10501061
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Region-based wavelet coding methods for digital mammography.
    Penedo M; Pearlman WA; Tahoces PG; Souto M; Vidal JJ
    IEEE Trans Med Imaging; 2003 Oct; 22(10):1288-96. PubMed ID: 14552582
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The compression of numerical radiological images].
    Trippi D; Russo G; Talone P; Caramella D
    Radiol Med; 1994 Nov; 88(5):631-42. PubMed ID: 7824780
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of visually lossless irreversible image compression: comparison of three methods by using an image-comparison workstation.
    Slone RM; Foos DH; Whiting BR; Muka E; Rubin DA; Pilgram TK; Kohm KS; Young SS; Ho P; Hendrickson DD
    Radiology; 2000 May; 215(2):543-53. PubMed ID: 10796938
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.