181 related articles for article (PubMed ID: 26492526)
1. A programmable Y-shaped junction scaffold-mediated modular and cascade amplification strategy for the one-step, isothermal and ultrasensitive detection of target DNA.
Liu S; Gong H; Sun X; Liu T; Wang L
Chem Commun (Camb); 2015 Dec; 51(100):17756-9. PubMed ID: 26492526
[TBL] [Abstract][Full Text] [Related]
2. A DNA machine for sensitive and homogeneous DNA detection via lambda exonuclease assisted amplification.
Liu L; Lei J; Gao F; Ju H
Talanta; 2013 Oct; 115():819-22. PubMed ID: 24054668
[TBL] [Abstract][Full Text] [Related]
3. Ultrasensitive fluorescence detection of nucleic acids using exonuclease III-induced cascade two-stage isothermal amplification-mediated zinc (II)-protoporphyrin IX/G-quadruplex supramolecular fluorescent nanotags.
Xue Q; Lv Y; Zhang Y; Xu S; Li R; Yue Q; Li H; Wang L; Gu X; Zhang S; Liu J
Biosens Bioelectron; 2014 Nov; 61():351-6. PubMed ID: 24912035
[TBL] [Abstract][Full Text] [Related]
4. Exonuclease III-assisted cascade signal amplification strategy for label-free and ultrasensitive electrochemical detection of nucleic acids.
Xiong E; Yan X; Zhang X; Liu Y; Zhou J; Chen J
Biosens Bioelectron; 2017 Jan; 87():732-736. PubMed ID: 27657839
[TBL] [Abstract][Full Text] [Related]
5. An autocatalytic DNA machine with autonomous target recycling and cascade circular exponential amplification for one-pot, isothermal and ultrasensitive nucleic acid detection.
Sun X; Wang L; Zhao M; Zhao C; Liu S
Chem Commun (Camb); 2016 Sep; 52(74):11108-11. PubMed ID: 27546809
[TBL] [Abstract][Full Text] [Related]
6. Label-free and ultrasensitive colorimetric detection of DNA based on target-triggered quadratic amplification strategy.
Wu H; Liu Y; Wang H; Wu J; Zhu F; Zou P
Biosens Bioelectron; 2015 Apr; 66():277-82. PubMed ID: 25437364
[TBL] [Abstract][Full Text] [Related]
7. Label-free electrochemical nucleic acid biosensing by tandem polymerization and cleavage-mediated cascade target recycling and DNAzyme amplification.
Liu S; Gong H; Wang Y; Wang L
Biosens Bioelectron; 2016 Mar; 77():818-23. PubMed ID: 26513289
[TBL] [Abstract][Full Text] [Related]
8. A three-line lateral flow biosensor for logic detection of microRNA based on Y-shaped junction DNA and target recycling amplification.
Huang Y; Wang W; Wu T; Xu LP; Wen Y; Zhang X
Anal Bioanal Chem; 2016 Nov; 408(28):8195-8202. PubMed ID: 27624762
[TBL] [Abstract][Full Text] [Related]
9. Detection of DNA 3'-phosphatase activity based on exonuclease III-assisted cascade recycling amplification reaction.
Zhang Y; Wang Y; Rizvi SFA; Zhang Y; Zhang Y; Liu X; Zhang H
Talanta; 2019 Nov; 204():499-506. PubMed ID: 31357325
[TBL] [Abstract][Full Text] [Related]
10. A Label-free and Turn-on Fluorescence Strategy for DNA Detection with a Wide Detection Range Based on Exonuclease III-aided Target Recycling Amplification.
Yang H; Song X; Ding B; Li Z; Zhang X
Anal Sci; 2017; 33(1):9-11. PubMed ID: 28070084
[TBL] [Abstract][Full Text] [Related]
11. Highly sensitive fluorescence detection of target DNA by coupling exonuclease-assisted cascade target recycling and DNAzyme amplification.
Liu S; Cheng C; Liu T; Wang L; Gong H; Li F
Biosens Bioelectron; 2015 Jan; 63():99-104. PubMed ID: 25063920
[TBL] [Abstract][Full Text] [Related]
12. Fluorescence detection of telomerase activity in cancer cell extracts based on autonomous exonuclease III-assisted isothermal cycling signal amplification.
Ding C; Li X; Wang W; Chen Y
Biosens Bioelectron; 2016 Sep; 83():102-5. PubMed ID: 27108253
[TBL] [Abstract][Full Text] [Related]
13. A Label-free and Highly Sensitive Fluorescence Strategy for Mercury Ion Detection Based on Exonuclease III-aided Recycling Amplification.
Ding B; Liu C; Wu Q; Wang Y; Li L; Yang H
Anal Sci; 2018; 34(3):259-261. PubMed ID: 29526891
[TBL] [Abstract][Full Text] [Related]
14. Ultrasensitive detection of small molecule-protein interaction via terminal protection of small molecule linked DNA and Exo III-aided DNA recycling amplification.
Zhou G; Zhang X; Ji X; He Z
Chem Commun (Camb); 2013 Oct; 49(78):8854-6. PubMed ID: 23964359
[TBL] [Abstract][Full Text] [Related]
15. Exonuclease III-aided autocatalytic DNA biosensing platform for immobilization-free and ultrasensitive electrochemical detection of nucleic acid and protein.
Liu S; Lin Y; Wang L; Liu T; Cheng C; Wei W; Tang B
Anal Chem; 2014 Apr; 86(8):4008-15. PubMed ID: 24655032
[TBL] [Abstract][Full Text] [Related]
16. Exonuclease III-boosted cascade reactions for ultrasensitive SERS detection of nucleic acids.
Sun Y; Peng P; Guo R; Wang H; Li T
Biosens Bioelectron; 2018 May; 104():32-38. PubMed ID: 29306030
[TBL] [Abstract][Full Text] [Related]
17. Exonuclease III-Powered Self-Propelled DNA Machine for Distinctly Amplified Detection of Nucleic Acid and Protein.
Liu S; Yu X; Wang J; Liu D; Wang L; Liu S
Anal Chem; 2020 Jul; 92(14):9764-9771. PubMed ID: 32527089
[TBL] [Abstract][Full Text] [Related]
18. A simple enzyme-assisted cascade amplification strategy for ultrasensitive and label-free detection of DNA.
Wang K; Zhai FH; He MQ; Wang J; Yu YL; He RH
Anal Bioanal Chem; 2019 Jul; 411(19):4569-4576. PubMed ID: 30327835
[TBL] [Abstract][Full Text] [Related]
19. Amplified detection of DNA by an analyte-induced Y-shaped junction probe assembly followed with a nicking endonuclease-mediated autocatalytic recycling process.
Liu S; Zhang C; Ming J; Wang C; Liu T; Li F
Chem Commun (Camb); 2013 Sep; 49(72):7947-9. PubMed ID: 23900658
[TBL] [Abstract][Full Text] [Related]
20. A novel magneto-DNA duplex probe for bacterial DNA detection based on exonuclease III-aided cycling amplification.
Zeng Y; Wan Y; Zhang D; Qi P
Talanta; 2015 Jan; 132():59-64. PubMed ID: 25476279
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]