BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

460 related articles for article (PubMed ID: 26500232)

  • 1. Delayed aneurysm rupture due to residual blood flow at the inflow zone of the intracranial paraclinoid internal carotid aneurysm treated with the Pipeline embolization device: Histopathological investigation.
    Ikeda H; Ishii A; Kikuchi T; Ando M; Chihara H; Arai D; Hattori E; Miyamoto S
    Interv Neuroradiol; 2015 Dec; 21(6):674-83. PubMed ID: 26500232
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pipeline flow diversion of ruptured blister aneurysms of the supraclinoid carotid artery using a single-device strategy.
    Ryan RW; Khan AS; Barco R; Choulakian A
    Neurosurg Focus; 2017 Jun; 42(6):E11. PubMed ID: 28565992
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transvenous Coil Embolization for the Treatment of Carotid Cavernous Fistula after Pipeline Placement: A Case Report.
    Nakae R; Nagaishi M; Takano I; Tanaka Y; Hyodo A; Suzuki K
    J Stroke Cerebrovasc Dis; 2018 Apr; 27(4):e65-e69. PubMed ID: 29174523
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Early angiographic occlusion of ruptured blister aneurysms of the internal carotid artery using the Pipeline Embolization Device as a primary treatment option.
    Hu YC; Chugh C; Mehta H; Stiefel MF
    J Neurointerv Surg; 2014 Dec; 6(10):740-3. PubMed ID: 24297367
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Delayed Posttreatment Residual Flow into Aneurysm After Flow Diverter Placement.
    Nakae R; Takigawa T; Hirata K; Nagaishi M; Hyodo A; Suzuki K
    World Neurosurg; 2018 Aug; 116():205-208. PubMed ID: 29852305
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Patency of anterior circulation branch vessels after Pipeline embolization: longer-term results from 82 aneurysm cases.
    Rangel-Castilla L; Munich SA; Jaleel N; Cress MC; Krishna C; Sonig A; Snyder KV; Siddiqui AH; Levy EI
    J Neurosurg; 2017 Apr; 126(4):1064-1069. PubMed ID: 27285547
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms.
    Xiang J; Damiano RJ; Lin N; Snyder KV; Siddiqui AH; Levy EI; Meng H
    J Neurosurg; 2015 Oct; 123(4):832-40. PubMed ID: 26090829
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Delayed migration of a pipeline embolization device.
    Chalouhi N; Satti SR; Tjoumakaris S; Dumont AS; Gonzalez LF; Rosenwasser R; Jabbour P
    Neurosurgery; 2013 Jun; 72(2 Suppl Operative):ons229-34; discussion ons234. PubMed ID: 23190638
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.
    Cannizzaro D; Peschillo S; Mancarella C; La Pira B; Rastelli E; Passacantilli E; Santoro A
    J Stroke Cerebrovasc Dis; 2017 Jun; 26(6):e114-e118. PubMed ID: 28416090
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optic chiasm compression from mass effect and thrombus formation following unsuccessful treatment of a giant supraclinoid ICA aneurysm with the Pipeline device: open surgical bailout with STA-MCA bypass and parent vessel occlusion.
    Abla AA; Zaidi HA; Crowley RW; Britz GW; McDougall CG; Albuquerque FC; Spetzler RF
    J Neurosurg Pediatr; 2014 Jul; 14(1):31-7. PubMed ID: 24835048
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pipeline flow diversion with adjunctive coil embolization for internal carotid artery aneurysms following an intradural component: results in 46 consecutive aneurysms from a Japanese single-center experience.
    Akiyama T; Imamura H; Goto M; Fukumitsu R; Sunohara T; Matsumoto S; Fukui N; Omura Y; Fukuda T; Go K; Kajiura S; Shigeyasu M; Asakura K; Horii R; Naramoto Y; Nishii R; Yamamoto Y; Sakai C; Sakai N
    Neurosurg Rev; 2022 Jun; 45(3):2221-2230. PubMed ID: 35066661
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rapid delayed growth of ruptured supraclinoid blister aneurysm after successful flow diverting stent treatment.
    Lang ST; Assis Z; Wong JH; Morrish W; Mitha AP
    J Neurointerv Surg; 2017 Apr; 9(4):e16. PubMed ID: 27471186
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid delayed growth of ruptured supraclinoid blister aneurysm after successful flow diverting stent treatment.
    Lang ST; Assis Z; Wong JH; Morrish W; Mitha AP
    BMJ Case Rep; 2016 Jul; 2016():. PubMed ID: 27436031
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative Computed Tomographic Volumetry after Treatment of a Giant Intracranial Aneurysm with a Pipeline Embolization Device.
    Lee WJ; Byun JS; Kim JK; Nam TK
    Yonsei Med J; 2017 May; 58(3):668-671. PubMed ID: 28332378
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pipeline embolization device retraction and foreshortening after internal carotid artery blister aneurysm treatment.
    Heit JJ; Telischak NA; Do HM; Dodd RL; Steinberg GK; Marks MP
    Interv Neuroradiol; 2017 Dec; 23(6):614-619. PubMed ID: 28758549
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extracranial-Intracranial High-Flow Bypass for Giant Ruptured Paraclinoid Aneurysm with Concomitant Bilateral Internal Carotid Artery Stenotic Dissection.
    Georgieva VB; Krastev ED; Byulbyuleva SK
    World Neurosurg; 2018 Sep; 117():265-270. PubMed ID: 29936212
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Recurrence of a giant fusiform aneurysm after neck clipping: case report].
    Iwamuro Y; Miyake H; Ito T; Kumai J; Kuroda T; Sugino T
    No Shinkei Geka; 1996 Apr; 24(4):357-61. PubMed ID: 8934889
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mural destabilization after aneurysm treatment with a flow-diverting device: a report of two cases.
    Hampton T; Walsh D; Tolias C; Fiorella D
    J Neurointerv Surg; 2011 Jun; 3(2):167-71. PubMed ID: 21990812
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pipeline Embolization of Giant Cavernous Internal Carotid Artery Aneurysm with Direct Carotid Puncture and Arteriotomy Closure Device: Neuroendovascular Surgical Video.
    Brunozzi D; Shakur SF; Alaraj A
    World Neurosurg; 2019 Mar; 123():40. PubMed ID: 30529526
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Early Fatal Hemorrhage After Endovascular Treatment of a Giant Aneurysm with Flow Diverter Device and Coils.
    Briganti F; Leone G; Napoli M; Lauriola W; Florio F; Maiuri F
    Clin Neuroradiol; 2015 Jun; 25(2):201-5. PubMed ID: 24838287
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 23.