These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 26502352)

  • 1. Trans-Endplate Pedicle Pillar System in Unstable Spinal Burst Fractures: Design, Technique, and Mechanical Evaluation.
    Zhao C; Hongo M; Ilharreborde B; Zhao KD; Currier BL; An KN
    PLoS One; 2015; 10(10):e0139592. PubMed ID: 26502352
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical evaluation of short-segment posterior instrumentation with and without crosslinks in a human cadaveric unstable thoracolumbar burst fracture model.
    Wahba GM; Bhatia N; Bui CN; Lee KH; Lee TQ
    Spine (Phila Pa 1976); 2010 Feb; 35(3):278-85. PubMed ID: 20075769
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures.
    Norton RP; Milne EL; Kaimrajh DN; Eismont FJ; Latta LL; Williams SK
    Spine J; 2014 Aug; 14(8):1734-9. PubMed ID: 24462814
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Treatment of thoracolumbar burst fractures by short-segment pedicle screw fixation using a combination of two additional pedicle screws and vertebroplasty at the level of the fracture: a finite element analysis.
    Liao JC; Chen WP; Wang H
    BMC Musculoskelet Disord; 2017 Jun; 18(1):262. PubMed ID: 28619021
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical evaluation of monosegmental pedicle instrumentation in a calf spine model and the role of fractured vertebrae in screw stability.
    Wei F; Zhou Z; Wang L; Liu S; Zhong R; Liu X; Cui S; Pan X; Gao M; Zhao Y
    BMC Vet Res; 2016 Mar; 12():57. PubMed ID: 26993472
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Properties of an interspinous fixation device (ISD) in lumbar fusion constructs: a biomechanical study.
    Techy F; Mageswaran P; Colbrunn RW; Bonner TF; McLain RF
    Spine J; 2013 May; 13(5):572-9. PubMed ID: 23498926
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Vertebroplasty plus short segment pedicle screw fixation in a burst fracture model in cadaveric spines.
    Grossbach AJ; Viljoen SV; Hitchon PW; DeVries Watson NA; Grosland NM; Torner J
    J Clin Neurosci; 2015 May; 22(5):883-8. PubMed ID: 25769251
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical Analysis of Pedicle Screw Fixation for Thoracolumbar Burst Fractures.
    McDonnell M; Shah KN; Paller DJ; Thakur NA; Koruprolu S; Palumbo MA; Daniels AH
    Orthopedics; 2016 May; 39(3):e514-8. PubMed ID: 27135451
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical evaluation of a simulated T-9 burst fracture of the thoracic spine with an intact rib cage.
    Perry TG; Mageswaran P; Colbrunn RW; Bonner TF; Francis T; McLain RF
    J Neurosurg Spine; 2014 Sep; 21(3):481-8. PubMed ID: 24949903
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Short Segment Spinal Instrumentation With Index Vertebra Pedicle Screw Placement for Pathologies Involving the Anterior and Middle Vertebral Column Is as Effective as Long Segment Stabilization With Cage Reconstruction: A Biomechanical Study.
    Bartanusz V; Harris J; Moldavsky M; Cai Y; Bucklen B
    Spine (Phila Pa 1976); 2015 Nov; 40(22):1729-36. PubMed ID: 26536447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical testing of anterior and posterior thoracolumbar instrumentation in the cadaveric spine. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004.
    Eichholz KM; Hitchon PW; From A; Rubenbauer P; Nakamura S; Lim TH; Torner J
    J Neurosurg Spine; 2004 Jul; 1(1):116-21. PubMed ID: 15291031
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical assessment of anterior lumbar interbody fusion with an anterior lumbosacral fixation screw-plate: comparison to stand-alone anterior lumbar interbody fusion and anterior lumbar interbody fusion with pedicle screws in an unstable human cadaver model.
    Gerber M; Crawford NR; Chamberlain RH; Fifield MS; LeHuec JC; Dickman CA
    Spine (Phila Pa 1976); 2006 Apr; 31(7):762-8. PubMed ID: 16582849
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical advantage of the index-level pedicle screw in unstable thoracolumbar junction fractures.
    Baaj AA; Reyes PM; Yaqoobi AS; Uribe JS; Vale FL; Theodore N; Sonntag VK; Crawford NR
    J Neurosurg Spine; 2011 Feb; 14(2):192-7. PubMed ID: 21214311
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: special references of hook configurations and pedicle screws.
    An HS; Singh K; Vaccaro AR; Wang G; Yoshida H; Eck J; McGrady L; Lim TH
    Spine (Phila Pa 1976); 2004 Feb; 29(3):257-62. PubMed ID: 14752346
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical comparison of iliac screws versus interbody femoral ring allograft on lumbosacral kinematics and sacral screw strain.
    Cunningham BW; Sefter JC; Hu N; Kim SW; Bridwell KH; McAfee PC
    Spine (Phila Pa 1976); 2010 Mar; 35(6):E198-205. PubMed ID: 20195199
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Short-segment fixation of lumbar burst fractures using pedicle fixation at the level of the fracture.
    Mahar A; Kim C; Wedemeyer M; Mitsunaga L; Odell T; Johnson B; Garfin S
    Spine (Phila Pa 1976); 2007 Jun; 32(14):1503-7. PubMed ID: 17572619
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Short-segment pedicle instrumentation. Biomechanical analysis of supplemental hook fixation.
    Chiba M; McLain RF; Yerby SA; Moseley TA; Smith TS; Benson DR
    Spine (Phila Pa 1976); 1996 Feb; 21(3):288-94. PubMed ID: 8742203
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical analysis in a human cadaveric model of spinous process fixation with an interlaminar allograft spacer for lumbar spinal stenosis: Laboratory investigation.
    Pradhan BB; Turner AW; Zatushevsky MA; Cornwall GB; Rajaee SS; Bae HW
    J Neurosurg Spine; 2012 Jun; 16(6):585-93. PubMed ID: 22519928
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical contribution of transverse connectors to segmental stability following long segment instrumentation with thoracic pedicle screws.
    Kuklo TR; Dmitriev AE; Cardoso MJ; Lehman RA; Erickson M; Gill NW
    Spine (Phila Pa 1976); 2008 Jul; 33(15):E482-7. PubMed ID: 18594445
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Biomechanical evaluation of posterior instrumentation for lumbar burst fracture: comparison of two internal devices].
    Freslon M; Mosnier T; Gayet LE; Skalli W
    Rev Chir Orthop Reparatrice Appar Mot; 2007 May; 93(3):213-21. PubMed ID: 17534203
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.