324 related articles for article (PubMed ID: 26508016)
1. Characterizing 3D printing in the fabrication of variable density phantoms for quality assurance of radiotherapy.
Madamesila J; McGeachy P; Villarreal Barajas JE; Khan R
Phys Med; 2016 Jan; 32(1):242-7. PubMed ID: 26508016
[TBL] [Abstract][Full Text] [Related]
2. Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications.
Makris DN; Pappas EP; Zoros E; Papanikolaou N; Saenz DL; Kalaitzakis G; Zourari K; Efstathopoulos E; Maris TG; Pappas E
Phys Med Biol; 2019 May; 64(10):105009. PubMed ID: 30965289
[TBL] [Abstract][Full Text] [Related]
3. A customizable anthropomorphic phantom for dosimetric verification of 3D-printed lung, tissue, and bone density materials.
Tino RB; Yeo AU; Brandt M; Leary M; Kron T
Med Phys; 2022 Jan; 49(1):52-69. PubMed ID: 34796527
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry.
Pappas E; Kalaitzakis G; Boursianis T; Zoros E; Zourari K; Pappas EP; Makris D; Seimenis I; Efstathopoulos E; Maris TG
Phys Med Biol; 2019 Nov; 64(22):225009. PubMed ID: 31665709
[TBL] [Abstract][Full Text] [Related]
5. Patient specific 3D printed phantom for IMRT quality assurance.
Ehler ED; Barney BM; Higgins PD; Dusenbery KE
Phys Med Biol; 2014 Oct; 59(19):5763-73. PubMed ID: 25207965
[TBL] [Abstract][Full Text] [Related]
6. Verification of Acuros XB dose algorithm using 3D printed low-density phantoms for clinical photon beams.
Zavan R; McGeachy P; Madamesila J; Villarreal-Barajas JE; Khan R
J Appl Clin Med Phys; 2018 May; 19(3):32-43. PubMed ID: 29575596
[TBL] [Abstract][Full Text] [Related]
7. High precision film dosimetry with GAFCHROMIC films for quality assurance especially when using small fields.
Mack A; Mack G; Weltz D; Scheib SG; Böttcher HD; Seifert V
Med Phys; 2003 Sep; 30(9):2399-409. PubMed ID: 14528962
[TBL] [Abstract][Full Text] [Related]
8. Three-dimensional printer-generated patient-specific phantom for artificial in vivo dosimetry in radiotherapy quality assurance.
Kamomae T; Shimizu H; Nakaya T; Okudaira K; Aoyama T; Oguchi H; Komori M; Kawamura M; Ohtakara K; Monzen H; Itoh Y; Naganawa S
Phys Med; 2017 Dec; 44():205-211. PubMed ID: 29102154
[TBL] [Abstract][Full Text] [Related]
9. 3D-printed applicators for high dose rate brachytherapy: Dosimetric assessment at different infill percentage.
Ricotti R; Vavassori A; Bazani A; Ciardo D; Pansini F; Spoto R; Sammarco V; Cattani F; Baroni G; Orecchia R; Jereczek-Fossa BA
Phys Med; 2016 Dec; 32(12):1698-1706. PubMed ID: 27592531
[TBL] [Abstract][Full Text] [Related]
10. Technical Note: The design, construction, and evaluation of a liquid-based single phantom solution for TG128 brachytherapy ultrasound QA.
Leong B; Ostyn M; Oh S; Kim S
Med Phys; 2019 Feb; 46(2):1024-1029. PubMed ID: 30472737
[TBL] [Abstract][Full Text] [Related]
11. Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology.
Tran-Gia J; Schlögl S; Lassmann M
J Nucl Med; 2016 Dec; 57(12):1998-2005. PubMed ID: 27445291
[TBL] [Abstract][Full Text] [Related]
12. Development of a 3D printed phantom for commissioning and quality assurance of multiple brain targets stereotactic radiosurgery.
Mukwada G; Hirst A; Rowshanfarzad P; Ebert MA
Phys Eng Sci Med; 2024 Jun; 47(2):455-463. PubMed ID: 38285271
[TBL] [Abstract][Full Text] [Related]
13. Technical Note: Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments.
Esplen N; Alyaqoub E; Bazalova-Carter M
Med Phys; 2019 Feb; 46(2):1030-1036. PubMed ID: 30488962
[TBL] [Abstract][Full Text] [Related]
14. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT.
Korevaar EW; Wauben DJ; van der Hulst PC; Langendijk JA; Van't Veld AA
Radiother Oncol; 2011 Sep; 100(3):446-52. PubMed ID: 21963288
[TBL] [Abstract][Full Text] [Related]
15. A modern mold room: Meshing 3D surface scanning, digital design, and 3D printing with bolus fabrication.
Sasaki DK; McGeachy P; Alpuche Aviles JE; McCurdy B; Koul R; Dubey A
J Appl Clin Med Phys; 2019 Sep; 20(9):78-85. PubMed ID: 31454148
[TBL] [Abstract][Full Text] [Related]
16. Quality assurance for a six degrees-of-freedom table using a 3D printed phantom.
Woods K; Ayan AS; Woollard J; Gupta N
J Appl Clin Med Phys; 2018 Jan; 19(1):115-124. PubMed ID: 29159920
[TBL] [Abstract][Full Text] [Related]
17. Volumetric-modulated arc therapy: effective and efficient end-to-end patient-specific quality assurance.
O'Daniel J; Das S; Wu QJ; Yin FF
Int J Radiat Oncol Biol Phys; 2012 Apr; 82(5):1567-74. PubMed ID: 21470797
[TBL] [Abstract][Full Text] [Related]
18. An anthropomorphic 3D printed inhomogeneity thorax phantom slab for SBRT commissioning and quality assurance.
How S; Banjade D; Crowe S; Dillon G; Skimmings A
Phys Eng Sci Med; 2023 Jun; 46(2):575-583. PubMed ID: 36806158
[TBL] [Abstract][Full Text] [Related]
19. Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy.
Kim MJ; Lee SR; Lee MY; Sohn JW; Yun HG; Choi JY; Jeon SW; Suh TS
PLoS One; 2017; 12(5):e0176227. PubMed ID: 28472175
[TBL] [Abstract][Full Text] [Related]
20. Sum signal dosimetry: A new approach for high dose quality assurance with Gafchromic EBT3.
Cusumano D; Fumagalli ML; Ghielmetti F; Rossi L; Grossi G; Lanzarotti R; Fariselli L; De Martin E
J Appl Clin Med Phys; 2017 Mar; 18(2):181-190. PubMed ID: 28300373
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]