These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 26510424)

  • 1. Answer to the Letter to the Editor of J. M. Duart-Clemente et al. concerning "Systematic review of the effect of dynamic fixation systems compared with rigid fixation in the anterior cervical spine" by Campos RR, Botelho RV; Eur Spine J (2014); 23(2):298-304.
    Campos RR; Botelho RV
    Eur Spine J; 2016 Apr; 25(4):1298. PubMed ID: 26510424
    [No Abstract]   [Full Text] [Related]  

  • 2. Letter to the Editor concerning "Systematic review of the effect of dynamic fixation systems compared with rigid fixation in the anterior cervical spine" by Campos RR, Botelho RV (Eur Spine J. 2014 Feb; 23(2):298-304).
    Duart-Clemente JM; Gandía-González ML; Álvarez-Galovich L; Duart-Clemente JV
    Eur Spine J; 2016 Apr; 25(4):1297. PubMed ID: 26507320
    [No Abstract]   [Full Text] [Related]  

  • 3. Answer to the Letter to the Editor of R.E.E. Omaña et al. concerning “Anterior pedicle screw fixation of C2: an anatomic analysis of axis morphology and simulated surgical fixation” by Zeng-Hui Wu et al. Eur Spine J (2014) 23:356-361.
    Wu ZH; Li XS; Xu JJ
    Eur Spine J; 2014 Sep; 23(9):2006-7. PubMed ID: 25015178
    [No Abstract]   [Full Text] [Related]  

  • 4. Answer to the letter to the editor of J.M. Duart Clemente et al. concerning "multilevel oblique corpectomy for cervical spondylotic myelopathy preserves segmental motion" by AG Chacko, M Joseph, MK Turel, K Prabhu, RT Daniel, KS Jacob (2012) Eur Spine J. 2012;21(7):1360-1367.
    Chacko AG; Joseph M; Turel MK; Prabhu K; Daniel RT; Jacob KS
    Eur Spine J; 2013 Sep; 22(9):2122. PubMed ID: 23880869
    [No Abstract]   [Full Text] [Related]  

  • 5. Letter to the Editor concerning the article "Anterior pedicle screw fixation of C2: an anatomic analysis of axis morphology and simulated surgical fixation" [Zeng-Hui Wu et al. (2014); Eur Spine J 23(2):356-361].
    Morales-Avalos R; Cortes-González PT; Vílchez-Cavazos F; Elizondo-Omaña RE; Guzmán-López S
    Eur Spine J; 2014 Sep; 23(9):2004-5. PubMed ID: 24952004
    [No Abstract]   [Full Text] [Related]  

  • 6. Systematic review of the effect of dynamic fixation systems compared with rigid fixation in the anterior cervical spine.
    Campos RR; Botelho RV
    Eur Spine J; 2014 Feb; 23(2):298-304. PubMed ID: 24057264
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Answer to the Letter to the Editor of C. Brembilla et al. concerning "Dynamic cervical myelopathy in young adults" by Hattou L, Morandi X, Le Reste PJ, et al: Eur Spine J 2014, 23:1515-22.
    Hénaux PL
    Eur Spine J; 2015 Jun; 24(6):1320. PubMed ID: 25749684
    [No Abstract]   [Full Text] [Related]  

  • 8. Answer to the letter to the editor of N. Balak concerning "Anatomic relationship between the cervical sympathetic trunk and cervical fascia and its application in the anterolateral cervical spine surgical approach" by M. Chen, et al. (Eur Spine J 30; 425-430).
    Chen M; Shan J
    Eur Spine J; 2022 Jan; 31(1):208-209. PubMed ID: 34718867
    [No Abstract]   [Full Text] [Related]  

  • 9. Posterior lateral mass plate fixation of the cervical spine.
    Lindsey RW; Miclau T
    J South Orthop Assoc; 2000; 9(1):36-42; discussion 42. PubMed ID: 12132809
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anterior plate instrumentation for disorders of the subaxial cervical spine.
    Vaccaro AR; Balderston RA
    Clin Orthop Relat Res; 1997 Feb; (335):112-21. PubMed ID: 9020211
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Anterior metallic spondylodesis of the cervical segment of the spine].
    Ellamaa AN
    Zh Vopr Neirokhir Im N N Burdenko; 1985; (5):46-50. PubMed ID: 3907225
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does rigid instrumentation increase the fusion rate in one-level anterior cervical discectomy and fusion?
    Samartzis D; Shen FH; Lyon C; Phillips M; Goldberg EJ; An HS
    Spine J; 2004; 4(6):636-43. PubMed ID: 15541695
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Letter to the Editor concerning "Complications of cervical total disc replacement and their associations with heterotopic ossification: a systematic review and meta-analysis" by N. Hui, et al. [Eur Spine J; 2020; 29(11):2688-2700].
    Shen YW; Liu H
    Eur Spine J; 2021 Jun; 30(6):1786-1787. PubMed ID: 33751233
    [No Abstract]   [Full Text] [Related]  

  • 14. Letter to the Editor regarding the article "Dynamic cervical myelopathy in young adults" by Hattou L, Morandi X, Le Reste PJ, et al.: Eur Spine J 2014, 23:1515-22.
    Brembilla C; Lanterna LA; Bernucci C
    Eur Spine J; 2015 Jun; 24(6):1318-9. PubMed ID: 25663646
    [No Abstract]   [Full Text] [Related]  

  • 15. Implant complications, fusion, loss of lordosis, and outcome after anterior cervical plating with dynamic or rigid plates: two-year results of a multi-centric, randomized, controlled study.
    Pitzen TR; Chrobok J; Stulik J; Ruffing S; Drumm J; Sova L; Kucera R; Vyskocil T; Steudel WI
    Spine (Phila Pa 1976); 2009 Apr; 34(7):641-6. PubMed ID: 19287352
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of bioresorbable and titanium plates in cervical spinal fusion: early radiologic and clinical results.
    Nabhan A; Ishak B; Steimer O; Zimmer A; Pitzen T; Steudel WI; Pape D
    J Spinal Disord Tech; 2009 May; 22(3):155-61. PubMed ID: 19412016
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Anterior cervical discectomy and fusion with a locked plate and wedged graft effectively stabilizes flexion-distraction stage-3 injury in the lower cervical spine: a biomechanical study.
    Paxinos O; Ghanayem AJ; Zindrick MR; Voronov LI; Havey RM; Carandang G; Hadjipavlou A; Patwardhan AG
    Spine (Phila Pa 1976); 2009 Jan; 34(1):E9-15. PubMed ID: 19127153
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Answer to the Letter to the Editor of Jianqiang Ni et al. concerning "Anterior stand-alone fusion revisited: a prospective clinical, X-ray and CT investigation" by Siepe C.J., et al. Eur Spine J (2014): DOI 10.1007/s00586-014-3642-y.
    Siepe CJ
    Eur Spine J; 2015 Jun; 24(6):1328-9. PubMed ID: 25724686
    [No Abstract]   [Full Text] [Related]  

  • 19. Biomechanical performance of rigid compared to dynamic anterior cervical plating: analysis of adjacent upper and lower level compressive forces.
    Connor DE; Shamieh KS; Ogden AL; Mukherjee DP; Sin A; Nanda A
    J Clin Neurosci; 2012 Dec; 19(12):1706-10. PubMed ID: 23084351
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Biomechanical evaluation of five fixation techniques for the lower cervical spine].
    Wang D; Tang T; Huang S; Yang H; Zhu Q; Oyang J
    Zhonghua Wai Ke Za Zhi; 1999 May; 37(5):301-3. PubMed ID: 11829846
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.