BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

233 related articles for article (PubMed ID: 26511638)

  • 1. Biomechanical comparison of pin and tension-band wire fixation with a prototype locking plate fixation in a transverse canine patellar fracture model.
    Gibert S; Kowaleski MP; Matthys R; Nützi R; Serck B; Boudrieau RJ
    Vet Comp Orthop Traumatol; 2016; 29(1):20-8. PubMed ID: 26511638
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
    Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
    Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures.
    Wagner FC; Neumann MV; Wolf S; Jonaszik A; Izadpanah K; Piatek S; Südkamp NP
    Injury; 2020 Jun; 51(6):1281-1287. PubMed ID: 32197829
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of two alternative tibial plateau leveling osteotomy plates with the original standard in an axially loaded gap model: an in vitro study.
    Kloc PA; Kowaleski MP; Litsky AS; Brown NO; Johnson KA
    Vet Surg; 2009 Jan; 38(1):40-8. PubMed ID: 19152616
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of pin and nitinol bone staple fixation to pin and tension band wire fixation for the stabilization of canine olecranon osteotomies.
    Lai A; Christou C; Bailey C; Tan CJ; Culvenor J; Wang T; Walsh WR
    Vet Comp Orthop Traumatol; 2017 Sep; 30(5):324-330. PubMed ID: 28763518
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro biomechanical evaluation and comparison of a new prototype locking plate and a limited-contact self compression plate for equine fracture repair.
    Quinteros DD; García-López JM; Abuja GA; Tarkanian M; Maranda LS; Bubeck K; Kowaleski MP
    Vet Comp Orthop Traumatol; 2012; 25(4):273-80. PubMed ID: 22695636
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical comparison of a novel tensioned cable construct versus tension band wiring for transverse patella fracture fixation.
    Kagan BD; Sundet AD; Gardner-Morse M; Chaidarun PL; Beynnon BD; Schottel PC
    Eur J Orthop Surg Traumatol; 2023 Jul; 33(5):1573-1580. PubMed ID: 35759107
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Biomechanical Study of an Alternative Internal Fixation Method for Transverse Patella Fractures.
    Han S; Li D; Zhang P; Yin X; Kou Y; Han N; Fu Z
    Orthopedics; 2018 Sep; 41(5):e643-e648. PubMed ID: 30011055
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Biomechanics test of fixation of star-shaped six-part patellar fractures with petal-shaped poly-axial locking plate].
    Meng D; Ouyang Y; Chen H; Zhou J; Xie Z; Lin Y; Lin H; Hou C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Mar; 32(3):311-315. PubMed ID: 29806280
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical comparison of a 3.5-mm conical coupling plating system and a 3.5-mm locking compression plate applied as plate-rod constructs to an experimentally created fracture gap in femurs of canine cadavers.
    Tremolada G; Lewis DD; Paragnani KL; Conrad BP; Kim SE; Pozzi A
    Am J Vet Res; 2017 Jun; 78(6):712-717. PubMed ID: 28541152
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A biomechanical comparison of Kirschner-wire fixation on fracture stability in Salter-Harris type I fractures of the proximal humeral physis in a porcine cadaveric model.
    Ma J; Wang T; Lovric V; Johnson KA; Walsh WR
    BMC Vet Res; 2017 Oct; 13(1):306. PubMed ID: 29070026
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
    Nienhaus M; Zderic I; Wahl D; Gueorguiev B; Rommens PM
    J Bone Joint Surg Am; 2018 Jun; 100(12):e83. PubMed ID: 29916933
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro biomechanical comparison of 3.5 string of pearl plate fixation to 3.5 locking compression plate fixation in a canine fracture gap model.
    Malenfant RC; Sod GA
    Vet Surg; 2014 May; 43(4):465-70. PubMed ID: 24720361
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora.
    Goh CS; Santoni BG; Puttlitz CM; Palmer RH
    Am J Vet Res; 2009 Jan; 70(1):23-9. PubMed ID: 19119945
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical evaluation of simulated feline patellar fracture repairs.
    Longley M; Langley-Hobbs S; Tarlton J
    Vet Comp Orthop Traumatol; 2017 Mar; 30(2):125-130. PubMed ID: 28094421
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tibial Tuberosity Transposition Fixation with a Locking Plate during Medial Patellar Luxation Surgery: An Ex Vivo Mechanical Study.
    Eskelinen EV; Suhonen AP; Virolainen JV; Liska WD
    Vet Comp Orthop Traumatol; 2022 Mar; 35(2):96-104. PubMed ID: 34634824
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.
    Thelen S; Schneppendahl J; Jopen E; Eichler C; Koebke J; Schönau E; Hakimi M; Windolf J; Wild M
    Injury; 2012 Aug; 43(8):1290-5. PubMed ID: 22608600
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
    Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
    Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study.
    Dickens AJ; Salas C; Rise L; Murray-Krezan C; Taha MR; DeCoster TA; Gehlert RJ
    Injury; 2015; 46(6):1001-6. PubMed ID: 25769202
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Novel techniques demonstrate superior fixation of simple transverse patella fractures - A biomechanical study.
    Lenihan J; Ramos-Pascual S; Silvestros P; Beak P; Miles AW; Trompeter A
    Injury; 2020 Jun; 51(6):1288-1293. PubMed ID: 32276726
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.