233 related articles for article (PubMed ID: 26511638)
1. Biomechanical comparison of pin and tension-band wire fixation with a prototype locking plate fixation in a transverse canine patellar fracture model.
Gibert S; Kowaleski MP; Matthys R; Nützi R; Serck B; Boudrieau RJ
Vet Comp Orthop Traumatol; 2016; 29(1):20-8. PubMed ID: 26511638
[TBL] [Abstract][Full Text] [Related]
2. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
[TBL] [Abstract][Full Text] [Related]
3. Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures.
Wagner FC; Neumann MV; Wolf S; Jonaszik A; Izadpanah K; Piatek S; Südkamp NP
Injury; 2020 Jun; 51(6):1281-1287. PubMed ID: 32197829
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical comparison of two alternative tibial plateau leveling osteotomy plates with the original standard in an axially loaded gap model: an in vitro study.
Kloc PA; Kowaleski MP; Litsky AS; Brown NO; Johnson KA
Vet Surg; 2009 Jan; 38(1):40-8. PubMed ID: 19152616
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical comparison of pin and nitinol bone staple fixation to pin and tension band wire fixation for the stabilization of canine olecranon osteotomies.
Lai A; Christou C; Bailey C; Tan CJ; Culvenor J; Wang T; Walsh WR
Vet Comp Orthop Traumatol; 2017 Sep; 30(5):324-330. PubMed ID: 28763518
[TBL] [Abstract][Full Text] [Related]
6. In vitro biomechanical evaluation and comparison of a new prototype locking plate and a limited-contact self compression plate for equine fracture repair.
Quinteros DD; García-López JM; Abuja GA; Tarkanian M; Maranda LS; Bubeck K; Kowaleski MP
Vet Comp Orthop Traumatol; 2012; 25(4):273-80. PubMed ID: 22695636
[TBL] [Abstract][Full Text] [Related]
7. Biomechanical comparison of a novel tensioned cable construct versus tension band wiring for transverse patella fracture fixation.
Kagan BD; Sundet AD; Gardner-Morse M; Chaidarun PL; Beynnon BD; Schottel PC
Eur J Orthop Surg Traumatol; 2023 Jul; 33(5):1573-1580. PubMed ID: 35759107
[TBL] [Abstract][Full Text] [Related]
8. A Biomechanical Study of an Alternative Internal Fixation Method for Transverse Patella Fractures.
Han S; Li D; Zhang P; Yin X; Kou Y; Han N; Fu Z
Orthopedics; 2018 Sep; 41(5):e643-e648. PubMed ID: 30011055
[TBL] [Abstract][Full Text] [Related]
9. [Biomechanics test of fixation of star-shaped six-part patellar fractures with petal-shaped poly-axial locking plate].
Meng D; Ouyang Y; Chen H; Zhou J; Xie Z; Lin Y; Lin H; Hou C
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Mar; 32(3):311-315. PubMed ID: 29806280
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical comparison of a 3.5-mm conical coupling plating system and a 3.5-mm locking compression plate applied as plate-rod constructs to an experimentally created fracture gap in femurs of canine cadavers.
Tremolada G; Lewis DD; Paragnani KL; Conrad BP; Kim SE; Pozzi A
Am J Vet Res; 2017 Jun; 78(6):712-717. PubMed ID: 28541152
[TBL] [Abstract][Full Text] [Related]
11. A biomechanical comparison of Kirschner-wire fixation on fracture stability in Salter-Harris type I fractures of the proximal humeral physis in a porcine cadaveric model.
Ma J; Wang T; Lovric V; Johnson KA; Walsh WR
BMC Vet Res; 2017 Oct; 13(1):306. PubMed ID: 29070026
[TBL] [Abstract][Full Text] [Related]
12. A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
Nienhaus M; Zderic I; Wahl D; Gueorguiev B; Rommens PM
J Bone Joint Surg Am; 2018 Jun; 100(12):e83. PubMed ID: 29916933
[TBL] [Abstract][Full Text] [Related]
13. In vitro biomechanical comparison of 3.5 string of pearl plate fixation to 3.5 locking compression plate fixation in a canine fracture gap model.
Malenfant RC; Sod GA
Vet Surg; 2014 May; 43(4):465-70. PubMed ID: 24720361
[TBL] [Abstract][Full Text] [Related]
14. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora.
Goh CS; Santoni BG; Puttlitz CM; Palmer RH
Am J Vet Res; 2009 Jan; 70(1):23-9. PubMed ID: 19119945
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical evaluation of simulated feline patellar fracture repairs.
Longley M; Langley-Hobbs S; Tarlton J
Vet Comp Orthop Traumatol; 2017 Mar; 30(2):125-130. PubMed ID: 28094421
[TBL] [Abstract][Full Text] [Related]
16. Tibial Tuberosity Transposition Fixation with a Locking Plate during Medial Patellar Luxation Surgery: An Ex Vivo Mechanical Study.
Eskelinen EV; Suhonen AP; Virolainen JV; Liska WD
Vet Comp Orthop Traumatol; 2022 Mar; 35(2):96-104. PubMed ID: 34634824
[TBL] [Abstract][Full Text] [Related]
17. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.
Thelen S; Schneppendahl J; Jopen E; Eichler C; Koebke J; Schönau E; Hakimi M; Windolf J; Wild M
Injury; 2012 Aug; 43(8):1290-5. PubMed ID: 22608600
[TBL] [Abstract][Full Text] [Related]
18. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
[TBL] [Abstract][Full Text] [Related]
19. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study.
Dickens AJ; Salas C; Rise L; Murray-Krezan C; Taha MR; DeCoster TA; Gehlert RJ
Injury; 2015; 46(6):1001-6. PubMed ID: 25769202
[TBL] [Abstract][Full Text] [Related]
20. Novel techniques demonstrate superior fixation of simple transverse patella fractures - A biomechanical study.
Lenihan J; Ramos-Pascual S; Silvestros P; Beak P; Miles AW; Trompeter A
Injury; 2020 Jun; 51(6):1288-1293. PubMed ID: 32276726
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]