These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

389 related articles for article (PubMed ID: 2651614)

  • 1. Results of mechanical circulatory assistance before heart transplantation.
    Oaks TE; Wisman CB; Pae WE; Pennock JL; Burg J; Pierce WS
    J Heart Transplant; 1989; 8(2):113-5. PubMed ID: 2651614
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Heart transplantation in patients requiring preoperative mechanical support.
    Bolman RM; Spray TL; Cox JL; Kouchoukos N; Cance C; Saffitz J; Genton RE; Eisen H
    J Heart Transplant; 1987; 6(5):273-80. PubMed ID: 3316551
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanical support of the circulation followed by cardiac transplantation.
    Pennock JL; Pierce WS; Campbell DB; Pae WE; Davis D; Hensley FA; Richenbacher WE; Waldhausen JA
    J Thorac Cardiovasc Surg; 1986 Dec; 92(6):994-1004. PubMed ID: 3537535
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Perioperative mechanical circulatory support for transplantation.
    Marks JD; Karwande SV; Richenbacher WE; Jones KW; Doty DB; Millar RC; O'Connell JB; Renlund DG; Bristow MR; Pantalos GM
    J Heart Lung Transplant; 1992; 11(1 Pt 1):117-28. PubMed ID: 1531769
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bridging to heart transplantation with circulatory support devices.
    Pennington DG; McBride LR; Kanter KR; Miller LW; Ruzevich SA; Naunheim K; Swartz MT; Termuhlen D
    J Heart Transplant; 1989; 8(2):116-23. PubMed ID: 2651615
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Seven years' experience with the Pierce-Donachy ventricular assist device.
    Pennington DG; Kanter KR; McBride LR; Kaiser GC; Barner HB; Miller LW; Naunheim KS; Fiore AC; Willman V
    J Thorac Cardiovasc Surg; 1988 Dec; 96(6):901-11. PubMed ID: 3057290
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical circulatory support as a bridge to transplantation.
    Joyce LD; Emery RW; Eales F; Von Rueden TJ; Kiser JC; Hoffman FM; Johnson KE; Toninato CJ; Kersten TE; Nicoloff DM
    J Thorac Cardiovasc Surg; 1989 Nov; 98(5 Pt 2):935-40; discussion 940-1. PubMed ID: 2811424
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Heart transplantation after mechanical circulatory support: four years' experience.
    Birovljev S; Radovancevic B; Burnett CM; Vega JD; Bennink G; Lonquist JL; Duncan JM; Frazier OH
    J Heart Lung Transplant; 1992; 11(2 Pt 1):240-5. PubMed ID: 1576128
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Possibilities of using cardiovascular assist systems and the artificial heart].
    Urbaszek W
    Z Gesamte Inn Med; 1986 May; 41(10):286-90. PubMed ID: 3529661
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Mechanical circulatory support today].
    von Segesser LK; Turina MI
    Schweiz Med Wochenschr; 1991 Dec; 121(51-52):1960-4. PubMed ID: 1763305
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Terminal cardiac failure. Circulatory assist devices].
    Duveau D; Baron O
    Arch Mal Coeur Vaiss; 1996 Nov; 89 Spec No 6():51-4. PubMed ID: 9092428
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Total artificial hearts and ventricular assist devices as bridges to heart transplantation.
    Lammermeier D; Frazier OH; Igo SR; Cooley DA
    Tex Med; 1988 Dec; 84(12):56-60. PubMed ID: 3064349
    [No Abstract]   [Full Text] [Related]  

  • 13. Staged cardiac transplantation. Total artificial heart or ventricular-assist pump?
    Pae WE; Pierce WS; Myers JL; Wisman CB; Campbell DB; Waldhausen JA
    Circulation; 1988 Nov; 78(5 Pt 2):III66-72. PubMed ID: 3052919
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early graft failure after heart transplantation: management by extracorporeal circulatory assist and retransplantation.
    Jurmann MJ; Wahlers T; Coppola R; Fieguth HG; Haverich A
    J Heart Transplant; 1989; 8(6):474-8. PubMed ID: 2614549
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardiac transplantation after mechanical circulatory support: a Canadian perspective.
    Masters RG; Hendry PJ; Davies RA; Smith S; Struthers C; Walley VM; Veinot JP; Mussivand TV; Keon WJ
    Ann Thorac Surg; 1996 Jun; 61(6):1734-9. PubMed ID: 8651776
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiac assist devices.
    Elefteriades JA
    Cardiol Clin; 1988 Aug; 6(3):449-59. PubMed ID: 3073010
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Successful use of left ventricular assist device for primary graft failure after heart transplantation.
    Hooper TL; Odom NJ; Fetherston GJ; Waterhouse P; Hilton CJ; Dark JH
    J Heart Transplant; 1988; 7(5):385-7. PubMed ID: 3058909
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preoperative predictors of survival in patients with Thoratec ventricular assist devices as a bridge to heart transplantation. Thoratec Ventricular Assist Device Principal Investigators.
    Farrar DJ
    J Heart Lung Transplant; 1994; 13(1 Pt 1):93-100; discussion 100-1. PubMed ID: 8167132
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical assistance for biventricular failure following coronary bypass operation and heart transplantation.
    Zumbro GL; Shearer G; Kitchens WR; Galloway RF
    J Heart Transplant; 1985 May; 4(3):348-52. PubMed ID: 3916506
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Follow-up of survivors of mechanical circulatory support.
    Kanter KR; Ruzevich SA; Pennington DG; McBride LR; Swartz MT; Willman VL
    J Thorac Cardiovasc Surg; 1988 Jul; 96(1):72-80. PubMed ID: 3386294
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.