These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 26519249)

  • 1. Near-Fatal ICD Lead Dysfunction with Implications for ICD Testing.
    Wutzler A; Attanasio P; Haverkamp W; Blaschke F
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):105-6. PubMed ID: 26519249
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrocautery-induced ventricular fibrillation during routine implantable cardioverter-defibrillator generator replacement.
    Cassagneau R; Hanninen M; Yee R
    Europace; 2014 Mar; 16(3):319. PubMed ID: 24068449
    [No Abstract]   [Full Text] [Related]  

  • 3. A rare cause of sensing integrity count in a patient with ICD and dedicated true bipolar lead.
    Erdogan O; Ozben B
    Pacing Clin Electrophysiol; 2013 Oct; 36(10):1301-5. PubMed ID: 23437820
    [No Abstract]   [Full Text] [Related]  

  • 4. Atrial tracking with a single ICD lead in the ventricle.
    Spears D; Selvaraj R; Dhopeswarkar R; Nanthakumar K
    J Cardiovasc Electrophysiol; 2008 Apr; 19(4):440-1. PubMed ID: 18298516
    [No Abstract]   [Full Text] [Related]  

  • 5. ICD shocks in a Brugada syndrome patient: what is the mechanism?
    Sacher F; Field ME; Laborderie J; Reuter S; Haissaguerre M; Clementy J
    J Cardiovasc Electrophysiol; 2007 Aug; 18(8):886-8. PubMed ID: 17506856
    [No Abstract]   [Full Text] [Related]  

  • 6. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Re: a rare cause of sensing integrity count in a patient with ICD and dedicated true bipolar lead.
    Cay S
    Pacing Clin Electrophysiol; 2013 Jul; 36(7):921. PubMed ID: 23663208
    [No Abstract]   [Full Text] [Related]  

  • 8. [Pacemaker quiz, 12th part].
    Israel CW; Vlachojannis GJ; Trepels T; Spyridopoulos I
    Herzschrittmacherther Elektrophysiol; 2006 Jun; 17(2):112-5. PubMed ID: 16786470
    [No Abstract]   [Full Text] [Related]  

  • 9. Causes of ventricular oversensing in implantable cardioverter-defibrillators: implications for diagnosis of lead fracture.
    Gunderson BD; Swerdlow CD; Wilcox JM; Hayman JE; Ousdigian KT; Ellenbogen KA
    Heart Rhythm; 2010 May; 7(5):626-33. PubMed ID: 20184977
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Non-functional lead as a cause of detection disturbances in implantable cardioverter-defibrillator].
    Kempa M; Budrejko S; Nowakowski M; Królak T; Daniłowicz-Szymanowicz L; Raczak G
    Kardiol Pol; 2012; 70(10):1073-5. PubMed ID: 23080104
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The "Pain wave": P‑wave oversensing in subcutaneous ICD.
    Kattih B; Duncker D; König T; Hohmann S; Oswald H; Veltmann C
    Herzschrittmacherther Elektrophysiol; 2016 Jun; 27(2):151-3. PubMed ID: 27084342
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multiple high lead impedances in an implantable-cardioverter defibrillator system: what is the mechanism?
    Ho RT
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1173-5. PubMed ID: 23594162
    [No Abstract]   [Full Text] [Related]  

  • 13. Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation.
    Farwell D; Redpath C; Birnie D; Gollob M; Lemery R; Posan E; Green M
    Europace; 2008 Jun; 10(6):726-8. PubMed ID: 18456645
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Twiddling with an implantable cardioverter-defibrillator.
    McCann CJ; Beelen R; Geelen P
    Acta Cardiol; 2009 Oct; 64(5):695. PubMed ID: 20058522
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads.
    Schmutz M; Delacrétaz E; Schwick N; Roten L; Fuhrer J; Boesch C; Tanner H
    Int J Cardiol; 2013 Jul; 167(1):254-7. PubMed ID: 22236515
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multiple inappropriate defibrillator discharges due to Twiddler's syndrome.
    Asbach S; Brunner M; Zehender M; Bode C; Faber TS
    Wien Klin Wochenschr; 2005 Dec; 117(23-24):801. PubMed ID: 16437315
    [No Abstract]   [Full Text] [Related]  

  • 17. Transvenous implantable cardioverter-defibrillator leads: the weakest link.
    Maisel WH
    Circulation; 2007 May; 115(19):2461-3. PubMed ID: 17502585
    [No Abstract]   [Full Text] [Related]  

  • 18. [ICD lead defects: diagnosis and therapeutical options].
    Wollmann CG; Böcker D; Löher A; Scheld HH; Breithardt G; Gradaus R
    Herzschrittmacherther Elektrophysiol; 2008 Dec; 19(4):169-80. PubMed ID: 19214417
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Early automatic remote detection of combined lead insulation defect and ICD damage.
    Neuzil P; Taborsky M; Holy F; Wallbrueck K
    Europace; 2008 May; 10(5):556-7. PubMed ID: 18227352
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fracture of an S-ICD lead after two prior transvenous lead-related complications with conventional defibrillators.
    Gutleben KJ; Nelovic V; Pujdak K; Werner M; Osmani I; Kähler J
    Pacing Clin Electrophysiol; 2020 Dec; 43(12):1491-1494. PubMed ID: 33085093
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.