670 related articles for article (PubMed ID: 26519948)
1. A semiadiabatic spectral-spatial spectroscopic imaging (SASSI) sequence for improved high-field MR spectroscopic imaging.
Feldman RE; Balchandani P
Magn Reson Med; 2016 Oct; 76(4):1071-82. PubMed ID: 26519948
[TBL] [Abstract][Full Text] [Related]
2. Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging.
Ma J; Wismans C; Cao Z; Klomp DWJ; Wijnen JP; Grissom WA
Magn Reson Med; 2018 Jan; 79(1):31-40. PubMed ID: 28370494
[TBL] [Abstract][Full Text] [Related]
3. Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T.
Balchandani P; Qiu D
Magn Reson Imaging; 2014 Sep; 32(7):804-12. PubMed ID: 24928300
[TBL] [Abstract][Full Text] [Related]
4. Three-dimensional MR spectroscopic imaging using adiabatic spin echo and hypergeometric dual-band suppression for metabolic mapping over the entire brain.
Esmaeili M; Bathen TF; Rosen BR; Andronesi OC
Magn Reson Med; 2017 Feb; 77(2):490-497. PubMed ID: 26840906
[TBL] [Abstract][Full Text] [Related]
5. Flexible proton 3D MR spectroscopic imaging of the prostate with low-power adiabatic pulses for volume selection and spiral readout.
Steinseifer IK; Philips BW; Gagoski B; Weiland E; Scheenen TW; Heerschap A
Magn Reson Med; 2017 Mar; 77(3):928-935. PubMed ID: 26968422
[TBL] [Abstract][Full Text] [Related]
6. A SEmi-Adiabatic matched-phase spin echo (SEAMS) PINS pulse-pair for B1 -insensitive simultaneous multislice imaging.
Feldman RE; Islam HM; Xu J; Balchandani P
Magn Reson Med; 2016 Feb; 75(2):709-17. PubMed ID: 25753055
[TBL] [Abstract][Full Text] [Related]
7. Interleaved narrow-band PRESS sequence with adiabatic spatial-spectral refocusing pulses for 1H MRSI at 7T.
Balchandani P; Pauly J; Spielman D
Magn Reson Med; 2008 May; 59(5):973-9. PubMed ID: 18429014
[TBL] [Abstract][Full Text] [Related]
8. Implementation of three-dimensional wavelet encoding spectroscopic imaging: in vivo application and method comparison.
Young R; Serrai H
Magn Reson Med; 2009 Jan; 61(1):6-15. PubMed ID: 19097215
[TBL] [Abstract][Full Text] [Related]
9. (1)H MR spectroscopic imaging of the prostate at 7T using spectral-spatial pulses.
Lagemaat MW; Breukels V; Vos EK; Kerr AB; van Uden MJ; Orzada S; Bitz AK; Maas MC; Scheenen TW
Magn Reson Med; 2016 Mar; 75(3):933-45. PubMed ID: 25943445
[TBL] [Abstract][Full Text] [Related]
10. Designing adiabatic radio frequency pulses using the Shinnar-Le Roux algorithm.
Balchandani P; Pauly J; Spielman D
Magn Reson Med; 2010 Sep; 64(3):843-51. PubMed ID: 20806378
[TBL] [Abstract][Full Text] [Related]
11. Improved volume selective (1) H MR spectroscopic imaging of the prostate with gradient offset independent adiabaticity pulses at 3 tesla.
Steinseifer IK; van Asten JJ; Weiland E; Scheenen TW; Maas MC; Heerschap A
Magn Reson Med; 2015 Oct; 74(4):915-24. PubMed ID: 25264976
[TBL] [Abstract][Full Text] [Related]
12. High-resolution (1) H-MRSI of the brain using SPICE: Data acquisition and image reconstruction.
Lam F; Ma C; Clifford B; Johnson CL; Liang ZP
Magn Reson Med; 2016 Oct; 76(4):1059-70. PubMed ID: 26509928
[TBL] [Abstract][Full Text] [Related]
13. MR fingerprinting using the quick echo splitting NMR imaging technique.
Jiang Y; Ma D; Jerecic R; Duerk J; Seiberlich N; Gulani V; Griswold MA
Magn Reson Med; 2017 Mar; 77(3):979-988. PubMed ID: 26924639
[TBL] [Abstract][Full Text] [Related]
14. Dielectric pads and low- B1+ adiabatic pulses: complementary techniques to optimize structural T1 w whole-brain MP2RAGE scans at 7 tesla.
O'Brien KR; Magill AW; Delacoste J; Marques JP; Kober T; Fautz HP; Lazeyras F; Krueger G
J Magn Reson Imaging; 2014 Oct; 40(4):804-12. PubMed ID: 24446194
[TBL] [Abstract][Full Text] [Related]
15. Neurologic 3D MR spectroscopic imaging with low-power adiabatic pulses and fast spiral acquisition.
Andronesi OC; Gagoski BA; Sorensen AG
Radiology; 2012 Feb; 262(2):647-61. PubMed ID: 22187628
[TBL] [Abstract][Full Text] [Related]
16. Fast three-dimensional 1H MR spectroscopic imaging at 7 Tesla using "spectroscopic missing pulse--SSFP".
Schuster C; Dreher W; Stadler J; Bernarding J; Leibfritz D
Magn Reson Med; 2008 Nov; 60(5):1243-9. PubMed ID: 18836998
[TBL] [Abstract][Full Text] [Related]
17. SLOW: A novel spectral editing method for whole-brain MRSI at ultra high magnetic field.
Weng G; Radojewski P; Sheriff S; Kiefer C; Schucht P; Wiest R; Maudsley AA; Slotboom J
Magn Reson Med; 2022 Jul; 88(1):53-70. PubMed ID: 35344608
[TBL] [Abstract][Full Text] [Related]
18. Ultrahigh field single-refocused diffusion weighted imaging using a matched-phase adiabatic spin echo (MASE).
Dyvorne H; O'Halloran R; Balchandani P
Magn Reson Med; 2016 May; 75(5):1949-57. PubMed ID: 26041650
[TBL] [Abstract][Full Text] [Related]
19. Test-retest reproducibility of neurochemical profiles with short-echo, single-voxel MR spectroscopy at 3T and 7T.
Terpstra M; Cheong I; Lyu T; Deelchand DK; Emir UE; Bednařík P; Eberly LE; Öz G
Magn Reson Med; 2016 Oct; 76(4):1083-91. PubMed ID: 26502373
[TBL] [Abstract][Full Text] [Related]
20. Flip-angle mapping of 31P coils by steady-state MR spectroscopic imaging.
Chmelík M; Považan M; Jírů F; Just Kukurová I; Dezortová M; Krššák M; Bogner W; Hájek M; Trattnig S; Valkovič L
J Magn Reson Imaging; 2014 Aug; 40(2):391-7. PubMed ID: 24925600
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]