These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

257 related articles for article (PubMed ID: 26526039)

  • 1. Computational Fluid Dynamics-Based Design Optimization Method for Archimedes Screw Blood Pumps.
    Yu H; Janiga G; Thévenin D
    Artif Organs; 2016 Apr; 40(4):341-52. PubMed ID: 26526039
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Shape optimization of the diffuser blade of an axial blood pump by computational fluid dynamics.
    Zhu L; Zhang X; Yao Z
    Artif Organs; 2010 Mar; 34(3):185-92. PubMed ID: 20447042
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computational fluid dynamics investigation of a centrifugal blood pump.
    Legendre D; Antunes P; Bock E; Andrade A; Biscegli JF; Ortiz JP
    Artif Organs; 2008 Apr; 32(4):342-8. PubMed ID: 18370951
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump.
    Arvand A; Hormes M; Reul H
    Artif Organs; 2005 Jul; 29(7):531-40. PubMed ID: 15982281
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental and Numerical Investigation of an Axial Rotary Blood Pump.
    Schüle CY; Thamsen B; Blümel B; Lommel M; Karakaya T; Paschereit CO; Affeld K; Kertzscher U
    Artif Organs; 2016 Nov; 40(11):E192-E202. PubMed ID: 27087467
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of a radial ventricular assist device using numerical predictions and experimental haemolysis.
    Carswell D; Hilton A; Chan C; McBride D; Croft N; Slone A; Cross M; Foster G
    Med Eng Phys; 2013 Aug; 35(8):1197-203. PubMed ID: 23384537
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Blood compatible design of a pulsatile blood pump using computational fluid dynamics and computer-aided design and manufacturing technology.
    Okamoto E; Hashimoto T; Inoue T; Mitamura Y
    Artif Organs; 2003 Jan; 27(1):61-7. PubMed ID: 12534714
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CFD-Based Flow Channel Optimization and Performance Prediction for a Conical Axial Maglev Blood Pump.
    Yang W; Peng S; Xiao W; Hu Y; Wu H; Li M
    Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214544
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design and Hemocompatibility Analysis of a Double-Suction Injection Suspension Blood Pump Using Computational Fluid Dynamics Methods.
    Wu Y; Zhu L; Luo Y
    Artif Organs; 2017 Nov; 41(11):979-987. PubMed ID: 28744907
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computational fluid dynamics-based hydraulic and hemolytic analyses of a novel left ventricular assist blood pump.
    Yang XC; Zhang Y; Gui XM; Hu SS
    Artif Organs; 2011 Oct; 35(10):948-55. PubMed ID: 21517911
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Heuristic optimization of impeller sidewall gaps-based on the bees algorithm for a centrifugal blood pump by CFD.
    Onder A; Incebay O; Sen MA; Yapici R; Kalyoncu M
    Int J Artif Organs; 2021 Oct; 44(10):765-772. PubMed ID: 34128420
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A design improvement strategy for axial blood pumps using computational fluid dynamics.
    Burgreen GW; Antaki JF; Griffith BP
    ASAIO J; 1996; 42(5):M354-60. PubMed ID: 8944906
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of computational fluid dynamics techniques to blood pumps.
    Sukumar R; Athavale MM; Makhijani VB; Przekwas AJ
    Artif Organs; 1996 Jun; 20(6):529-33. PubMed ID: 8817950
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computational fluid dynamics design and analysis of a passively suspended Tesla pump left ventricular assist device.
    Medvitz RB; Boger DA; Izraelev V; Rosenberg G; Paterson EG
    Artif Organs; 2011 May; 35(5):522-33. PubMed ID: 21595722
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of the Center Post Establishment and Its Design Variations on the Performance of a Centrifugal Rotary Blood Pump.
    Fang P; Du J; Yu S
    Cardiovasc Eng Technol; 2020 Aug; 11(4):337-349. PubMed ID: 32410073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Review of Hemolysis Prediction Models for Computational Fluid Dynamics.
    Yu H; Engel S; Janiga G; Thévenin D
    Artif Organs; 2017 Jul; 41(7):603-621. PubMed ID: 28643335
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computational design and in vitro characterization of an integrated maglev pump-oxygenator.
    Zhang J; Taskin ME; Koert A; Zhang T; Gellman B; Dasse KA; Gilbert RJ; Griffith BP; Wu ZJ
    Artif Organs; 2009 Oct; 33(10):805-17. PubMed ID: 19681842
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computational modeling of the Food and Drug Administration's benchmark centrifugal blood pump.
    Good BC; Manning KB
    Artif Organs; 2020 Jul; 44(7):E263-E276. PubMed ID: 31971269
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design optimization of an axial blood pump with computational fluid dynamics.
    Zhang Y; Zhan Z; Gui XM; Sun HS; Zhang H; Zheng Z; Zhou JY; Zhu XD; Li GR; Hu SS; Jin DH
    ASAIO J; 2008; 54(2):150-5. PubMed ID: 18356647
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics.
    Arvand A; Hahn N; Hormes M; Akdis M; Martin M; Reul H
    Artif Organs; 2004 Oct; 28(10):892-8. PubMed ID: 15384994
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.