BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

570 related articles for article (PubMed ID: 26526783)

  • 1. Early healing assessment with optical coherence tomography of everolimus-eluting stents with bioabsorbable polymer (synergy™) at 3 and 6 months after implantation.
    de la Torre Hernández JM; Tejedor P; Camarero TG; Duran JM; Lee DH; Monedero J; Laso FS; Calderón MA; Veiga G; Zueco J
    Catheter Cardiovasc Interv; 2016 Sep; 88(3):E67-73. PubMed ID: 26526783
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three-month evaluation of strut healing using a novel optical coherence tomography analytical method following bioresorbable polymer everolimus-eluting stent implantation in humans: the TIMELESS study.
    Vesga B; Hernandez H; Moncada M; Gasior P; Higuera S; Dager A; Arana C; Delgado JA; Généreux P; Maehara A; Granada JF
    Coron Artery Dis; 2017 Mar; 28(2):126-134. PubMed ID: 27879518
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial.
    Xu B; Zhang YJ; Sun ZW; Qiao SB; Chen SL; Zhang RY; Pan DR; Pang S; Zhang Q; Xu L; Yang YJ; Leon MB; Gao RL
    Int J Cardiovasc Imaging; 2015 Dec; 31(8):1489-96. PubMed ID: 26208685
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Very early neointimal coverage of new biodegradable polymer drug-eluting stent compared with durable polymer everolimus-eluting stent evaluated by optical frequency domain imaging.
    Kobayashi N; Ito Y; Yamawaki M; Araki M; Sakai T; Sakamoto Y; Mori S; Tsutsumi M; Nauchi M; Honda Y; Tokuda T; Makino K; Shirai S; Hirano K
    Int J Cardiovasc Imaging; 2018 Apr; 34(4):515-522. PubMed ID: 29159531
    [TBL] [Abstract][Full Text] [Related]  

  • 5. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).
    Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Very early tissue coverage after drug-eluting stent implantation: an optical coherence tomography study.
    Takahara M; Kitahara H; Nishi T; Miura K; Miyayama T; Sugimoto K; Nakayama T; Fujimoto Y; Kobayashi Y
    Int J Cardiovasc Imaging; 2017 Jan; 33(1):25-30. PubMed ID: 27601229
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Overtime evaluation of the vascular HEALing process after everolimus-eluting stent implantation by optical coherence tomography. The HEAL-EES study.
    Otsuki S; Brugaletta S; Sabaté M; Shiratori Y; Gomez-Monterrosas O; Scalone G; Romero-Villafañe S; Hernández-Enríquez M; Freixa X; Martín-Yuste V; Masotti M
    Cardiovasc Revasc Med; 2016 Jun; 17(4):241-7. PubMed ID: 27158001
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Morphological, Functional, and Biological Vascular Healing Response 6 Months After Drug-Eluting Stent Implantation: A Randomized Comparison of Three Drug-Eluting Stents.
    Nakata T; Fujii K; Fukunaga M; Shibuya M; Kawai K; Kawasaki D; Naito Y; Ohyanagi M; Masuyama T
    Catheter Cardiovasc Interv; 2016 Sep; 88(3):350-7. PubMed ID: 26526816
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.
    Ohtani H; Kimura S; Sugiyama T; Hishikari K; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Kojima K; Sagawa Y; Hikita H; Ashikaga T; Takahashi A; Isobe M
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):177-186. PubMed ID: 27761750
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging: The DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months).
    Chevalier B; Smits PC; Carrié D; Mehilli J; Van Boven AJ; Regar E; Sawaya FJ; Chamié D; Kraaijeveld AO; Hovasse T; Vlachojannis GJ
    Circ Cardiovasc Interv; 2017 Dec; 10(12):. PubMed ID: 29246909
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optical coherence tomography findings after chronic total occlusion interventions: Insights from the "AngiographiC evaluation of the everolimus-eluting stent in chronic Total occlusions" (ACE-CTO) study (NCT01012869).
    Sherbet DP; Christopoulos G; Karatasakis A; Danek BA; Kotsia A; Navara R; Michael TT; Roesle M; Rangan BV; Haagen D; Garcia S; Maniu C; Pershad A; Abdullah SM; Hastings JL; Kumbhani DJ; Luna M; Addo T; Banerjee S; Brilakis ES
    Cardiovasc Revasc Med; 2016; 17(7):444-449. PubMed ID: 27133499
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early Strut Coverage in Patients Receiving Drug-Eluting Stents and its Implications for Dual Antiplatelet Therapy: A Randomized Trial.
    Lee SY; Kim JS; Yoon HJ; Hur SH; Lee SG; Kim JW; Hong YJ; Kim KS; Choi SY; Shin DH; Nam CM; Kim BK; Ko YG; Choi D; Jang Y; Hong MK
    JACC Cardiovasc Imaging; 2018 Dec; 11(12):1810-1819. PubMed ID: 29454763
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Early vascular healing with rapid breakdown biodegradable polymer sirolimus-eluting versus durable polymer everolimus-eluting stents assessed by optical coherence tomography.
    Tada T; Byrne RA; Schuster T; Cuni R; Kitabata H; Tiroch K; Dirninger A; Gratze F; Kaspar K; Zenker G; Joner M; Schömig A; Kastrati A
    Cardiovasc Revasc Med; 2013; 14(2):84-9. PubMed ID: 23352095
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.
    Costa JR; Chamié D; Abizaid AA; Ribeiro E; Meireles GC; Prudente M; Campos CA; Castro JP; Costa R; Lemos PA
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):161-168. PubMed ID: 27714601
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Procedural resources utilization and clinical outcomes with bioresorbable everolimus-eluting scaffolds and Pt-Cr everolimus-eluting stent with resorbable abluminal polymer in clinical practice. A randomized trial.
    de la Torre Hernandez JM; Garcia Camarero T; Lee DH; Sainz Laso F; Veiga Fernandez G; Pino T; Rubio S; Legarra P; Valdivia JR; Zueco Gil J
    Catheter Cardiovasc Interv; 2017 Aug; 90(2):E25-E30. PubMed ID: 27807948
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The REMEDEE-OCT Study: An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis.
    Jaguszewski M; Aloysius R; Wang W; Bezerra HG; Hill J; De Winter RJ; Karjalainen PP; Verheye S; Wijns W; Lüscher TF; Joner M; Costa M; Landmesser U
    JACC Cardiovasc Interv; 2017 Mar; 10(5):489-499. PubMed ID: 28279316
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of neointimal coverage between durable-polymer everolimus-eluting stents and bioresorbable-polymer everolimus-eluting stents 1 year after implantation using high-resolution coronary angioscopy.
    Nojima Y; Adachi H; Ihara M; Kurimoto T; Okayama K; Sakata Y; Nanto S
    Catheter Cardiovasc Interv; 2019 Aug; 94(2):204-209. PubMed ID: 30737973
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of zotarolimus-eluting stent and everolimus-eluting stent for vascular healing response: serial 3-month and 12-month optical coherence tomography study.
    Kim SJ; Lee H; Cho JM; Park CB; Kim W; Kato K; Yonetsu T; Kim CJ; Jang IK
    Coron Artery Dis; 2013 Aug; 24(5):431-9. PubMed ID: 23722649
    [TBL] [Abstract][Full Text] [Related]  

  • 19. One-year head to head comparison of the neointimal response between sirolimus eluting stent with reservoir technology and everolimus eluting stent: an optical coherence tomography study.
    Shiratori Y; Brugaletta S; Alvarez-Contreras L; Azpeitia Y; Ospino N; Gaido S; Delahanty A; Santos A; Martin-Yuste V; Masotti M; Serruys PW; Windecker S; Sabaté M
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E428-36. PubMed ID: 23441068
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Difference of vascular healing between bioabsorbable-polymer and durable-polymer new generation drug-eluting stents: an optical coherence tomographic analysis.
    Matsuhiro Y; Nakamura D; Shutta R; Kawamura A; Nakamura H; Okamoto N; Matsunaga-Lee Y; Yano M; Egami Y; Sakata Y; Nishino M; Tanouchi J
    Int J Cardiovasc Imaging; 2021 Apr; 37(4):1131-1141. PubMed ID: 33165669
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.