These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 26527206)

  • 1. Diagnostic validity of the use of a portable single-channel electromyography device for sleep bruxism.
    Stuginski-Barbosa J; Porporatti AL; Costa YM; Svensson P; Conti PC
    Sleep Breath; 2016 May; 20(2):695-702. PubMed ID: 26527206
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of sleep bruxism: comparison between an electromyographic and electrocardiographic portable holter and polysomnography.
    Castroflorio T; Deregibus A; Bargellini A; Debernardi C; Manfredini D
    J Oral Rehabil; 2014 Mar; 41(3):163-9. PubMed ID: 24417585
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Agreement between jaw-muscle activity measurement with portable single-channel electromyography and polysomnography in children.
    Restrepo C; Lobbezoo F; Castrillon E; Svensson P; Santamaria A; Alvarez C; Manrique R; Manfredini D
    Int J Paediatr Dent; 2018 Jan; 28(1):33-42. PubMed ID: 28586093
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Agreement of the International Classification of Sleep Disorders Criteria with polysomnography for sleep bruxism diagnosis: A preliminary study.
    Stuginski-Barbosa J; Porporatti AL; Costa YM; Svensson P; Conti PC
    J Prosthet Dent; 2017 Jan; 117(1):61-66. PubMed ID: 27460312
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validity of single-channel masseteric electromyography by using an ultraminiature wearable electromyographic device for diagnosis of sleep bruxism.
    Maeda M; Yamaguchi T; Mikami S; Yachida W; Saito T; Sakuma T; Nakamura H; Saito M; Mizuno M; Yamada K; Satoh K
    J Prosthodont Res; 2020 Jan; 64(1):90-97. PubMed ID: 31085074
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnostic accuracy of portable instrumental devices to measure sleep bruxism: a systematic literature review of polysomnographic studies.
    Manfredini D; Ahlberg J; Castroflorio T; Poggio CE; Guarda-Nardini L; Lobbezoo F
    J Oral Rehabil; 2014 Nov; 41(11):836-42. PubMed ID: 25040303
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Agreement between clinical and portable EMG/ECG diagnosis of sleep bruxism.
    Castroflorio T; Bargellini A; Rossini G; Cugliari G; Deregibus A; Manfredini D
    J Oral Rehabil; 2015 Oct; 42(10):759-64. PubMed ID: 26059761
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Home Polysomnography Reveals a First-Night Effect in Patients With Low Sleep Bruxism Activity.
    Miettinen T; Myllymaa K; Hukkanen T; Töyräs J; Sipilä K; Myllymaa S
    J Clin Sleep Med; 2018 Aug; 14(8):1377-1386. PubMed ID: 30092900
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Diagnostic validity of self-reported measures of sleep bruxism using an ambulatory single-channel EMG device.
    Yachida W; Arima T; Castrillon EE; Baad-Hansen L; Ohata N; Svensson P
    J Prosthodont Res; 2016 Oct; 60(4):250-257. PubMed ID: 26876908
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic accuracy of a portable device (Bruxoff®) to measure sleep bruxism.
    Yanez-Regonesi F; Eisa E; Judge S; Carlson C; Okeson J; Moreno-Hay I
    J Oral Rehabil; 2023 Apr; 50(4):258-266. PubMed ID: 36648354
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ambulatory polysomnography for the assessment of sleep bruxism.
    Doering S; Boeckmann JA; Hugger S; Young P
    J Oral Rehabil; 2008 Aug; 35(8):572-6. PubMed ID: 18699968
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnostic accuracy of ambulatory polysomnography with electroencephalogram for detection of sleep bruxism-related masticatory muscle activity.
    Abe Y; Nakazato Y; Takaba M; Kawana F; Baba K; Kato T
    J Clin Sleep Med; 2023 Feb; 19(2):379-392. PubMed ID: 36305587
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validity of different tools to assess sleep bruxism: a meta-analysis.
    Casett E; Réus JC; Stuginski-Barbosa J; Porporatti AL; Carra MC; Peres MA; de Luca Canto G; Manfredini D
    J Oral Rehabil; 2017 Sep; 44(9):722-734. PubMed ID: 28477392
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A pilot study to test the validity of a piezoelectric intra-splint force detector for monitoring of sleep bruxism in comparison to portable polysomnography.
    Aoki R; Takaba M; Abe Y; Nakazato Y; Ohara H; Maejima K; Baba K
    J Oral Sci; 2022 Jan; 64(1):63-68. PubMed ID: 34955491
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the occurrence of sleep bruxism under accustomed conditions at home and under polysomnography conditions in a sleep laboratory.
    Sakuma T; Yamaguchi T; Maeda M; Saito T; Nakamura H; Mikami S; Saito M; Nakajima T; Mizuno M; Yamada K; Takahashi S; Takahashi M; Yachida W; Satoh K
    J Prosthodont Res; 2022 Oct; 66(4):630-638. PubMed ID: 35095085
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of a new diagnostic method for quantification of sleep bruxism activity.
    Ommerborn MA; Walentek N; Bergmann N; Franken M; Gotter A; Schäfer R
    Clin Oral Investig; 2022 Jun; 26(6):4351-4359. PubMed ID: 35195761
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of the Bitestrip versus polysomnography in the diagnosis of patients with a clinical history of sleep bruxism.
    Mainieri VC; Saueressig AC; Pattussi MP; Fagondes SC; Grossi ML
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2012 May; 113(5):612-7. PubMed ID: 22668619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multiple sleep bruxism data collected using a self-contained EMG detector/analyzer system in asymptomatic healthy subjects.
    Minakuchi H; Sakaguchi C; Hara ES; Maekawa K; Matsuka Y; Clark GT; Kuboki T
    Sleep Breath; 2012 Dec; 16(4):1069-72. PubMed ID: 22278147
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diagnostic accuracy of the use of parental-reported sleep bruxism in a polysomnographic study in children.
    Restrepo C; Manfredini D; Castrillon E; Svensson P; Santamaria A; Alvarez C; Manrique R; Lobbezoo F
    Int J Paediatr Dent; 2017 Sep; 27(5):318-325. PubMed ID: 27612328
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Identification of sleep bruxism with an ambulatory wireless recording system.
    Inano S; Mizumori T; Kobayashi Y; Sumiya M; Yatani H
    Int J Prosthodont; 2013; 26(6):527-35. PubMed ID: 24179965
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.