BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 26530957)

  • 1. [History of internal fixators. The subsequent importance for spinal surgery].
    Dick W; Rickert M
    Unfallchirurg; 2015 Dec; 118 Suppl 1():66-72. PubMed ID: 26530957
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Injuries of the lower cervical vertebrae--the monocortical stabilization technique].
    Stulík J; Krbec M; Vyskocil T
    Acta Chir Orthop Traumatol Cech; 2003; 70(4):226-32. PubMed ID: 14569859
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Limitations of dorsal transpedicular stabilization in unstable fractures of the lower thoracic and lumbar spine: an analysis of 133 patients.
    Oertel J; Niendorf WR; Darwish N; Schroeder HW; Gaab MR
    Acta Neurochir (Wien); 2004 Aug; 146(8):771-7. PubMed ID: 15254799
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Treatment of thoracolumbar spinal fractures using internal fixators (evaluation of 120 cases)].
    Krbec M; Stulík J
    Acta Chir Orthop Traumatol Cech; 2001; 68(2):77-84. PubMed ID: 11706721
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Design and experimental study of internal fixator for the reconstruction of lumbar isthmus].
    Hao Y; Deng S; Zhao H; Sun Z; Li J; Zhou J; Wang Z; Xu J; Yu S; Wang L; Wang R
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Apr; 23(4):408-11. PubMed ID: 19431975
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical evaluation of conventional internal contemporary spinal fixation techniques used for stabilization of complete sacroiliac joint separation: a 3-dimensional unilaterally isolated experimental stiffness study.
    Korovessis PG; Magnissalis EA; Deligianni D
    Spine (Phila Pa 1976); 2006 Dec; 31(25):E941-51. PubMed ID: 17139210
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The LS-8 lever fixator: repositioning and fixation aids for dislocations and dislocation fractures of the lumbar spine and the thoracolumbar transition. Part I. Biomechanical considerations and surgical technique].
    Sándor L
    Unfallchirurg; 1993 Jul; 96(7):367-72. PubMed ID: 8367731
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Corrosion on an internal spinal fixator system.
    Vieweg U; van Roost D; Wolf HK; Schyma CA; Schramm J
    Spine (Phila Pa 1976); 1999 May; 24(10):946-51. PubMed ID: 10332783
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Imaging current spine hardware: part 1, cervical spine and fracture fixation.
    Petscavage-Thomas JM; Ha AS
    AJR Am J Roentgenol; 2014 Aug; 203(2):394-405. PubMed ID: 25055276
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Single segment internal fixator device in treatment of thoracolumbar vertebral fractures].
    Wawro W; Konrad L; Aebi M
    Unfallchirurg; 1994 Mar; 97(3):114-20. PubMed ID: 8178177
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Simplified surgical technique and decreased radiation exposure in dorsal stabilization of spinal fractures].
    Friedl W
    Chirurg; 1992 Nov; 63(11):980-3. PubMed ID: 1458994
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Use of bioceramics in the treatment of fractures of the thoraco-lumbar spine].
    Stulík J; Krbec M; Vyskocil T
    Acta Chir Orthop Traumatol Cech; 2002; 69(5):288-94. PubMed ID: 12557599
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The minimally invasive stabilization of the dorsal pelvic ring with the transiliacal internal fixator (TIFI)--surgical technique and first clinical findings].
    Füchtmeier B; Maghsudi M; Neumann C; Hente R; Roll C; Nerlich M
    Unfallchirurg; 2004 Dec; 107(12):1142-51. PubMed ID: 15338033
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Classic: Current concepts review: internal fixation of fractures of the thoracolumbar spine. 1984.
    Stauffer ES
    Clin Orthop Relat Res; 2006 Feb; 443():135-8. PubMed ID: 16462437
    [No Abstract]   [Full Text] [Related]  

  • 15. From unstable internal fixation to biological osteosynthesis. A historical overview of operative fracture treatment.
    Broos PL; Sermon A
    Acta Chir Belg; 2004 Aug; 104(4):396-400. PubMed ID: 15469150
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pelvic Fixation in Adult and Pediatric Spine Surgery: Historical Perspective, Indications, and Techniques: AAOS Exhibit Selection.
    Jain A; Hassanzadeh H; Strike SA; Menga EN; Sponseller PD; Kebaish KM
    J Bone Joint Surg Am; 2015 Sep; 97(18):1521-8. PubMed ID: 26378268
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures.
    Wolf JC; Weil WM; Hanel DP; Trumble TE
    J Hand Surg Am; 2006 Dec; 31(10):1578-86. PubMed ID: 17145376
    [TBL] [Abstract][Full Text] [Related]  

  • 18. History of posterior thoracic instrumentation.
    Singh H; Rahimi SY; Yeh DJ; Floyd D
    Neurosurg Focus; 2004 Jan; 16(1):E11. PubMed ID: 15264789
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The design of an anti-rotation reduction internal fixator and its applications in spine fracture surgeries].
    Pan XM; Quan Y; Zhang B; Tan YJ; Liao DF; Liu JB
    Zhongguo Yi Liao Qi Xie Za Zhi; 2005 Jan; 29(1):27-8, 40. PubMed ID: 15875689
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Dorsal stabilization of fractures of the thoracic and lumbar spine by external fixator--technique and outcome].
    Pizanis A; Mutschler W
    Zentralbl Chir; 1998; 123(8):936-43. PubMed ID: 9757539
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.