169 related articles for article (PubMed ID: 26536254)
21. Extracting microtubule networks from superresolution single-molecule localization microscopy data.
Zhang Z; Nishimura Y; Kanchanawong P
Mol Biol Cell; 2017 Jan; 28(2):333-345. PubMed ID: 27852898
[TBL] [Abstract][Full Text] [Related]
22. 3-D reconstruction of microtubules from multi-angle total internal reflection fluorescence microscopy using Bayesian framework.
Yang Q; Karpikov A; Toomre D; Duncan JS
IEEE Trans Image Process; 2011 Aug; 20(8):2248-59. PubMed ID: 21324778
[TBL] [Abstract][Full Text] [Related]
23. Bayesian coestimation of phylogeny and sequence alignment.
Lunter G; Miklós I; Drummond A; Jensen JL; Hein J
BMC Bioinformatics; 2005 Apr; 6():83. PubMed ID: 15804354
[TBL] [Abstract][Full Text] [Related]
24. A protocol for registration and correction of multicolour STED superresolution images.
Hebisch E; Wagner E; Westphal V; Sieber JJ; Lehnart SE
J Microsc; 2017 Aug; 267(2):160-175. PubMed ID: 28370211
[TBL] [Abstract][Full Text] [Related]
25. Bayesian methods for FMRI time-series analysis using a nonstationary model for the noise.
Oikonomou VP; Tripoliti EE; Fotiadis DI
IEEE Trans Inf Technol Biomed; 2010 May; 14(3):664-74. PubMed ID: 20123577
[TBL] [Abstract][Full Text] [Related]
26. Variational algorithms to remove stationary noise: applications to microscopy imaging.
Fehrenbach J; Weiss P; Lorenzo C
IEEE Trans Image Process; 2012 Oct; 21(10):4420-30. PubMed ID: 22752131
[TBL] [Abstract][Full Text] [Related]
27. Voxel-based Bayesian lesion-symptom mapping.
Chen R; Herskovits EH
Neuroimage; 2010 Jan; 49(1):597-602. PubMed ID: 19647797
[TBL] [Abstract][Full Text] [Related]
28. [Bayesian representation of prior information and MCMC method in microwave imaging].
Zhao X; Huang K; Chen X; Yan L
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Dec; 22(6):1108-11. PubMed ID: 16422077
[TBL] [Abstract][Full Text] [Related]
29. Blind image deconvolution using machine learning for three-dimensional microscopy.
Kenig T; Kam Z; Feuer A
IEEE Trans Pattern Anal Mach Intell; 2010 Dec; 32(12):2191-204. PubMed ID: 20975117
[TBL] [Abstract][Full Text] [Related]
30. A Monte Carlo Metropolis-Hastings algorithm for sampling from distributions with intractable normalizing constants.
Liang F; Jin IH
Neural Comput; 2013 Aug; 25(8):2199-234. PubMed ID: 23607562
[TBL] [Abstract][Full Text] [Related]
31. Drift correction for single-molecule imaging by molecular constraint field, a distance minimum metric.
Han R; Wang L; Xu F; Zhang Y; Zhang M; Liu Z; Ren F; Zhang F
BMC Biophys; 2015; 8(1):1. PubMed ID: 25649266
[TBL] [Abstract][Full Text] [Related]
32. A Metropolis Monte Carlo implementation of bayesian time-domain parameter estimation: application to coupling constant estimation from antiphase multiplets.
Andrec M; Prestegard JH
J Magn Reson; 1998 Feb; 130(2):217-32. PubMed ID: 9500892
[TBL] [Abstract][Full Text] [Related]
33. Bayesian phylogeny analysis via stochastic approximation Monte Carlo.
Cheon S; Liang F
Mol Phylogenet Evol; 2009 Nov; 53(2):394-403. PubMed ID: 19589389
[TBL] [Abstract][Full Text] [Related]
34. Controlled Support MEG imaging.
Nagarajan SS; Portniaguine O; Hwang D; Johnson C; Sekihara K
Neuroimage; 2006 Nov; 33(3):878-85. PubMed ID: 16978882
[TBL] [Abstract][Full Text] [Related]
35. An automated vertical drift correction algorithm for AFM images based on morphology prediction.
Wu Y; Fang Y; Fan Z; Wang C; Liu C
Micron; 2021 Jan; 140():102950. PubMed ID: 33096453
[TBL] [Abstract][Full Text] [Related]
36. Bayesian segmentation of human facial tissue using 3D MR-CT information fusion, resolution enhancement and partial volume modelling.
Şener E; Mumcuoglu EU; Hamcan S
Comput Methods Programs Biomed; 2016 Feb; 124():31-44. PubMed ID: 26574298
[TBL] [Abstract][Full Text] [Related]
37. Design and implementation of algorithms for focus automation in digital imaging time-lapse microscopy.
LeSage AJ; Kron SJ
Cytometry; 2002 Dec; 49(4):159-69. PubMed ID: 12454979
[TBL] [Abstract][Full Text] [Related]
38. Fast two-dimensional super-resolution image reconstruction algorithm for ultra-high emitter density.
Huang J; Gumpper K; Chi Y; Sun M; Ma J
Opt Lett; 2015 Jul; 40(13):2989-92. PubMed ID: 26125349
[TBL] [Abstract][Full Text] [Related]
39. P- and T-wave delineation in ECG signals using a Bayesian approach and a partially collapsed Gibbs sampler.
Lin C; Mailhes C; Tourneret JY
IEEE Trans Biomed Eng; 2010 Dec; 57(12):2840-9. PubMed ID: 20851787
[TBL] [Abstract][Full Text] [Related]
40. Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting.
Bootsma GJ; Verhaegen F; Jaffray DA
Med Phys; 2015 Jan; 42(1):54-68. PubMed ID: 25563247
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]