These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
364 related articles for article (PubMed ID: 26541720)
1. Impact of novel shift handle laparoscopic tool on wrist ergonomics and task performance. Yu D; Lowndes B; Morrow M; Kaufman K; Bingener J; Hallbeck S Surg Endosc; 2016 Aug; 30(8):3480-90. PubMed ID: 26541720 [TBL] [Abstract][Full Text] [Related]
2. The effect of ergonomic laparoscopic tool handle design on performance and efficiency. Tung KD; Shorti RM; Downey EC; Bloswick DS; Merryweather AS Surg Endosc; 2015 Sep; 29(9):2500-5. PubMed ID: 25537377 [TBL] [Abstract][Full Text] [Related]
3. An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparoscopic grasper. Berguer R; Gerber S; Kilpatrick G; Beckley D Surg Endosc; 1998 Jun; 12(6):805-8. PubMed ID: 9601994 [TBL] [Abstract][Full Text] [Related]
4. An ergonomics study on wrist posture when using laparoscopic tools in four techniques in minimally invasive surgery. Bartnicka J; Zietkiewicz AA; Kowalski GJ Int J Occup Saf Ergon; 2018 Sep; 24(3):438-449. PubMed ID: 29553920 [TBL] [Abstract][Full Text] [Related]
5. Effect of a laparoscopic instrument with rotatable handle piece on biomechanical stress during laparoscopic procedures. Steinhilber B; Seibt R; Reiff F; Rieger MA; Kraemer B; Rothmund R Surg Endosc; 2016 Jan; 30(1):78-88. PubMed ID: 25829062 [TBL] [Abstract][Full Text] [Related]
7. Ergonomic evaluation and performance of a new handle for laparoscopic tools in surgery. Sancibrian R; Redondo-Figuero C; Gutierrez-Diez MC; Gonzalez-Sarabia E; Manuel-Palazuelos JC Appl Ergon; 2020 Nov; 89():103210. PubMed ID: 32658774 [TBL] [Abstract][Full Text] [Related]
8. Ergonomic Benefits of an Angle Grinder With Rotatable Main Handle in a Cutting Task. Reinvee M; Aia S; Pääsuke M Hum Factors; 2019 Nov; 61(7):1112-1124. PubMed ID: 30785831 [TBL] [Abstract][Full Text] [Related]
9. Training improves laparoscopic tasks performance and decreases operator workload. Hu JS; Lu J; Tan WB; Lomanto D Surg Endosc; 2016 May; 30(5):1742-6. PubMed ID: 26173550 [TBL] [Abstract][Full Text] [Related]
10. An ergonomic field study to evaluate the effects of a rotatable handle piece on muscular stress and fatigue as well as subjective ratings of usability, wrist posture and precision during laparoscopic surgery: an explorative pilot study. Kraemer B; Seibt R; Stoffels AK; Rothmund R; Brucker SY; Rieger MA; Steinhilber B Int Arch Occup Environ Health; 2018 Nov; 91(8):1021-1029. PubMed ID: 30078157 [TBL] [Abstract][Full Text] [Related]
11. Effect of handle design and target location on insertion and aim with a laparoscopic surgical tool. Trejo A; Jung MC; Oleynikov D; Hallbeck MS Appl Ergon; 2007 Nov; 38(6):745-53. PubMed ID: 17374356 [TBL] [Abstract][Full Text] [Related]
12. A randomized controlled study to establish the effect of articulating instruments on performance in single-incision laparoscopic surgery. Corker HP; Singh P; Sodergren MH; Balaji S; Kwasnicki RM; Darzi AW; Paraskeva P J Surg Educ; 2015; 72(1):1-7. PubMed ID: 25218370 [TBL] [Abstract][Full Text] [Related]
13. Ergonomic Benefits From a Laparoscopic Instrument With Rotatable Handle Piece Depend on the Area of the Operating Field and Working Height. Steinhilber B; Reiff F; Seibt R; Rieger MA; Martus P; Kraemer B; Rothmund R Hum Factors; 2017 Nov; 59(7):1048-1065. PubMed ID: 28628750 [TBL] [Abstract][Full Text] [Related]
15. Ergonomic aspects of five different types of laparoscopic instrument handles under dynamic conditions with respect to specific laparoscopic tasks: an electromyographic-based study. Matern U; Kuttler G; Giebmeyer C; Waller P; Faist M Surg Endosc; 2004 Aug; 18(8):1231-41. PubMed ID: 15457383 [TBL] [Abstract][Full Text] [Related]
16. The ergonomics of laparoscopic surgery: a quantitative study of the time and motion of laparoscopic surgeons in live surgical environments. Aitchison LP; Cui CK; Arnold A; Nesbitt-Hawes E; Abbott J Surg Endosc; 2016 Nov; 30(11):5068-5076. PubMed ID: 27059965 [TBL] [Abstract][Full Text] [Related]
17. Ergonomics investigation for orientation of the handles of wood routers. Bhardwaj S; Khan AA Int J Occup Saf Ergon; 2018 Dec; 24(4):592-604. PubMed ID: 28868989 [TBL] [Abstract][Full Text] [Related]
18. FLS tasks can be used as an ergonomic discriminator between laparoscopic and robotic surgery. Zihni AM; Ohu I; Cavallo JA; Ousley J; Cho S; Awad MM Surg Endosc; 2014 Aug; 28(8):2459-65. PubMed ID: 24619332 [TBL] [Abstract][Full Text] [Related]
19. Letter: In-line vs pistol-grip handles in a laparoscopic simulator. Moont M Surg Endosc; 2003 Nov; 17(11):1865; author reply 1866. PubMed ID: 14959746 [No Abstract] [Full Text] [Related]
20. Single-incision laparoscopic surgery (SILS™) versus standard laparoscopic surgery: a comparison of performance using a surgical simulator. Santos BF; Enter D; Soper NJ; Hungness ES Surg Endosc; 2011 Feb; 25(2):483-90. PubMed ID: 20585958 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]