These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

258 related articles for article (PubMed ID: 26542435)

  • 1. Sample injection and electrophoretic separation on a simple laminated paper based analytical device.
    Xu C; Zhong M; Cai L; Zheng Q; Zhang X
    Electrophoresis; 2016 Feb; 37(3):476-81. PubMed ID: 26542435
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High performance microfluidic capillary electrophoresis devices.
    Fu LM; Leong JC; Lin CF; Tai CH; Tsai CH
    Biomed Microdevices; 2007 Jun; 9(3):405-12. PubMed ID: 17487587
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Parallel separation of multiple samples with negative pressure sample injection on a 3-D microfluidic array chip.
    Zhang L; Yin X
    Electrophoresis; 2007 Apr; 28(8):1281-8. PubMed ID: 17366485
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Micromixer utilizing electrokinetic instability-induced shedding effect.
    Tai CH; Yang RJ; Huang MZ; Liu CW; Tsai CH; Fu LM
    Electrophoresis; 2006 Dec; 27(24):4982-90. PubMed ID: 17109376
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid microfluidic separation of magnetic beads through dielectrophoresis and magnetophoresis.
    Krishnan JN; Kim C; Park HJ; Kang JY; Kim TS; Kim SK
    Electrophoresis; 2009 May; 30(9):1457-63. PubMed ID: 19425001
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tunable electrophoretic separations using a scalable, fabric-based platform.
    Narahari T; Dendukuri D; Murthy SK
    Anal Chem; 2015 Feb; 87(4):2480-7. PubMed ID: 25582166
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous microfluidic DNA and protein trapping and concentration by balancing transverse electrokinetic forces.
    Morales MC; Lin H; Zahn JD
    Lab Chip; 2012 Jan; 12(1):99-108. PubMed ID: 22045330
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A low sample volume particle separation device with electrokinetic pumping based on circular travelling-wave electroosmosis.
    Lin SC; Lu JC; Sung YL; Lin CT; Tung YC
    Lab Chip; 2013 Aug; 13(15):3082-9. PubMed ID: 23753015
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Switchable pH actuators and 3D integrated salt bridges as new strategies for reconfigurable microfluidic free-flow electrophoretic separation.
    Cheng LJ; Chang HC
    Lab Chip; 2014 Mar; 14(5):979-87. PubMed ID: 24430103
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A centrifugal microfluidic device with integrated gold leaf electrodes for the electrophoretic separation of DNA.
    Thompson BL; Birch C; Nelson DA; Li J; DuVall JA; Le Roux D; Tsuei AC; Mills DL; Root BE; Landers JP
    Lab Chip; 2016 Nov; 16(23):4569-4580. PubMed ID: 27766331
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Negative pressure pinched sample injection for microchip-based electrophoresis.
    Zhang L; Yin X; Fang Z
    Lab Chip; 2006 Feb; 6(2):258-64. PubMed ID: 16450036
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual frequency dielectrophoresis with interdigitated sidewall electrodes for microfluidic flow-through separation of beads and cells.
    Wang L; Lu J; Marchenko SA; Monuki ES; Flanagan LA; Lee AP
    Electrophoresis; 2009 Mar; 30(5):782-91. PubMed ID: 19197906
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Charge-based particle separation in microfluidic devices using combined hydrodynamic and electrokinetic effects.
    Jellema LC; Mey T; Koster S; Verpoorte E
    Lab Chip; 2009 Jul; 9(13):1914-25. PubMed ID: 19532967
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrokinetic transport in nanochannels. 2. Experiments.
    Pennathur S; Santiago JG
    Anal Chem; 2005 Nov; 77(21):6782-9. PubMed ID: 16255574
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simple device for multiplexed electrophoretic separations using gradient elution moving boundary electrophoresis with channel current detection.
    Ross D; Kralj JG
    Anal Chem; 2008 Dec; 80(24):9467-74. PubMed ID: 19007187
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous dielectrophoretic cell separation microfluidic device.
    Li Y; Dalton C; Crabtree HJ; Nilsson G; Kaler KV
    Lab Chip; 2007 Feb; 7(2):239-48. PubMed ID: 17268627
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip.
    Gao J; Yin XF; Fang ZL
    Lab Chip; 2004 Feb; 4(1):47-52. PubMed ID: 15007440
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A dielectrophoretic continuous flow sorter using integrated microelectrodes coupled to a channel constriction.
    Salomon S; Leichlé T; Nicu L
    Electrophoresis; 2011 Jun; 32(12):1508-14. PubMed ID: 21563186
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid and variable-volume sample loading in sieving electrophoresis microchips using negative pressure combined with electrokinetic force.
    Qi LY; Yin XF; Zhang L; Wang M
    Lab Chip; 2008 Jul; 8(7):1137-44. PubMed ID: 18584090
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A microfluidic device for continuous capture and concentration of microorganisms from potable water.
    Balasubramanian AK; Soni KA; Beskok A; Pillai SD
    Lab Chip; 2007 Oct; 7(10):1315-21. PubMed ID: 17896016
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.