These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 26550021)

  • 1. An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes.
    Hu R; Li C
    Comput Math Methods Med; 2015; 2015():281589. PubMed ID: 26550021
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Physiologic insulin delivery with insulin feedback: a control systems perspective.
    Palerm CC
    Comput Methods Programs Biomed; 2011 May; 102(2):130-7. PubMed ID: 20674062
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adaptive fuzzy integral sliding mode control of blood glucose level in patients with type 1 diabetes: In silico studies.
    Asadi S; Nekoukar V
    Math Biosci; 2018 Nov; 305():122-132. PubMed ID: 30201283
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An improved PID switching control strategy for type 1 diabetes.
    Marchetti G; Barolo M; Jovanovic L; Zisser H; Seborg DE
    IEEE Trans Biomed Eng; 2008 Mar; 55(3):857-65. PubMed ID: 18334377
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Closed-loop control of artificial pancreatic Beta -cell in type 1 diabetes mellitus using model predictive iterative learning control.
    Wang Y; Dassau E; Doyle FJ
    IEEE Trans Biomed Eng; 2010 Feb; 57(2):211-9. PubMed ID: 19527957
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Method for automatic adjustment of an insulin bolus calculator: in silico robustness evaluation under intra-day variability.
    Herrero P; Pesl P; Bondia J; Reddy M; Oliver N; Georgiou P; Toumazou C
    Comput Methods Programs Biomed; 2015 Apr; 119(1):1-8. PubMed ID: 25733405
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In Silico Closed-Loop Control Validation Studies for Optimal Insulin Delivery in Type 1 Diabetes.
    Zavitsanou S; Mantalaris A; Georgiadis MC; Pistikopoulos EN
    IEEE Trans Biomed Eng; 2015 Oct; 62(10):2369-78. PubMed ID: 25935026
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparative study of different control techniques for the regulation of blood glucose level in diabetic patients.
    Ibbini MS
    J Med Eng Technol; 2009; 33(8):656-62. PubMed ID: 19848860
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simulation environment to evaluate closed-loop insulin delivery systems in type 1 diabetes.
    Wilinska ME; Chassin LJ; Acerini CL; Allen JM; Dunger DB; Hovorka R
    J Diabetes Sci Technol; 2010 Jan; 4(1):132-44. PubMed ID: 20167177
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An improved PID switching control strategy for type 1 diabetes.
    Marchetti G; Barolo M; Jovanovic L; Zisser H; Seborg DE
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5041-4. PubMed ID: 17947128
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A semiclosed-loop optimal control system for blood glucose level in diabetics.
    Ibbini MS; Masadeh MA; Amer MM
    J Med Eng Technol; 2004; 28(5):189-96. PubMed ID: 15370997
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A framework for specifying safe behavior of the CIIP medical system.
    Babamir SM
    Adv Exp Med Biol; 2011; 696():637-44. PubMed ID: 21431605
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Induced L₂-norm minimization of glucose-insulin system for Type I diabetic patients.
    Kovács L; Benyó B; Bokor J; Benyó Z
    Comput Methods Programs Biomed; 2011 May; 102(2):105-18. PubMed ID: 20674065
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automatic Artificial Pancreas Systems Using an Intelligent Multiple-Model PID Strategy.
    Batmani Y; Khodakaramzadeh S; Moradi P
    IEEE J Biomed Health Inform; 2022 Apr; 26(4):1708-1717. PubMed ID: 34587104
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automatic bolus and adaptive basal algorithm for the artificial pancreatic β-cell.
    Wang Y; Dassau E; Zisser H; Jovanovič L; Doyle FJ
    Diabetes Technol Ther; 2010 Nov; 12(11):879-87. PubMed ID: 20879966
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On-line adaptive algorithm with glucose prediction capacity for subcutaneous closed loop control of glucose: evaluation under fasting conditions in patients with Type 1 diabetes.
    Schaller HC; Schaupp L; Bodenlenz M; Wilinska ME; Chassin LJ; Wach P; Vering T; Hovorka R; Pieber TR
    Diabet Med; 2006 Jan; 23(1):90-3. PubMed ID: 16409572
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An insulin infusion advisory system based on autotuning nonlinear model-predictive control.
    Zarkogianni K; Vazeou A; Mougiakakou SG; Prountzou A; Nikita KS
    IEEE Trans Biomed Eng; 2011 Sep; 58(9):2467-77. PubMed ID: 21622071
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical validation of a new control-oriented model of insulin and glucose dynamics in subjects with type 1 diabetes.
    Fabietti PG; Canonico V; Orsini-Federici M; Sarti E; Massi-Benedetti M
    Diabetes Technol Ther; 2007 Aug; 9(4):327-38. PubMed ID: 17705688
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Artificial neural networks for closed loop control of in silico and ad hoc type 1 diabetes.
    Fernandez de Canete J; Gonzalez-Perez S; Ramos-Diaz JC
    Comput Methods Programs Biomed; 2012 Apr; 106(1):55-66. PubMed ID: 22178070
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In silico evaluation platform for artificial pancreatic beta-cell development--a dynamic simulator for closed-loop control with hardware-in-the-loop.
    Dassau E; Palerm CC; Zisser H; Buckingham BA; Jovanovic L; Doyle FJ
    Diabetes Technol Ther; 2009 Mar; 11(3):187-94. PubMed ID: 19191486
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.