These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
155 related articles for article (PubMed ID: 26550241)
21. Ambu® AuraGain™ versus LMA Supreme™ Second Seal™: a randomised controlled trial comparing oropharyngeal leak pressures and gastric drain functionality in spontaneously breathing patients. Shariffuddin II; Teoh WH; Tang E; Hashim N; Loh PS Anaesth Intensive Care; 2017 Mar; 45(2):244-250. PubMed ID: 28267947 [TBL] [Abstract][Full Text] [Related]
22. Assessment of head and neck position for optimal ultrasonographic visualisation of the internal jugular vein and its relation to the common carotid artery: A prospective observational study. Purohit G; Setlur R; Dhar M; Bhasin S J Anaesthesiol Clin Pharmacol; 2020; 36(1):62-65. PubMed ID: 32174660 [TBL] [Abstract][Full Text] [Related]
23. Comparison of the Supreme™ and ProSeal™ laryngeal mask airways in infants: a prospective randomised clinical study. Oba S; Turk HS; Isil CT; Erdogan H; Sayin P; Dokucu AI BMC Anesthesiol; 2017 Sep; 17(1):125. PubMed ID: 28870163 [TBL] [Abstract][Full Text] [Related]
24. Effect-site concentration of propofol required for LMA-Supreme™ insertion with and without remifentanil: a randomized controlled trial. Zaballos M; Bastida E; Agustí S; Portas M; Jiménez C; López-Gil M BMC Anesthesiol; 2015 Oct; 15():131. PubMed ID: 26438179 [TBL] [Abstract][Full Text] [Related]
25. Brief review: The LMA Supreme™ supraglottic airway. Wong DT; Yang JJ; Jagannathan N Can J Anaesth; 2012 May; 59(5):483-93. PubMed ID: 22318376 [TBL] [Abstract][Full Text] [Related]
26. Anatomic relationship of the internal jugular vein and the common carotid artery in Chinese people. Qin XH; Zhang H; Mi WD Chin Med J (Engl); 2010 Nov; 123(22):3226-30. PubMed ID: 21163120 [TBL] [Abstract][Full Text] [Related]
27. LMA Supreme™ vs i-gel™--a comparison of insertion success in novices. Ragazzi R; Finessi L; Farinelli I; Alvisi R; Volta CA Anaesthesia; 2012 Apr; 67(4):384-8. PubMed ID: 22329593 [TBL] [Abstract][Full Text] [Related]
28. Ultrasound analysis of the relationship between right internal jugular vein and common carotid artery in the left head-rotation and head-flexion position. Saitoh T; Satoh H; Kumazawa A; Nobuhara M; Machii M; Tanaka T; Shiraki K; Saotome M; Urushida T; Katoh H; Hayashi H Heart Vessels; 2013 Sep; 28(5):620-5. PubMed ID: 22968853 [TBL] [Abstract][Full Text] [Related]
29. Observation of ventilation effects of I-gel™, Supreme™ and Ambu AuraOnce™ with respiratory dynamics monitoring in small children. Gu Z; Jin Q; Liu J; Chen L J Clin Monit Comput; 2017 Oct; 31(5):1035-1041. PubMed ID: 27492428 [TBL] [Abstract][Full Text] [Related]
30. [Ultrasound evaluation of the anatomical relationships between common carotid arteries and internal jugular veins in children]. Kayashima K; Imai K; Sozen R Masui; 2013 Feb; 62(2):161-7. PubMed ID: 23479915 [TBL] [Abstract][Full Text] [Related]
31. Point-of-care ultrasound evaluation and puncture simulation of the internal jugular vein by medical students. Pazeli JM; Vieira ALS; Vicentino RS; Pazeli LJ; Lemos BC; Saliba MMR; Mello PA; Costa MD Crit Ultrasound J; 2018 Dec; 10(1):34. PubMed ID: 30564947 [TBL] [Abstract][Full Text] [Related]
32. Ultrasound evaluation of the anatomical characteristics of the internal jugular vein and carotid artery--facilitation of internal jugular vein cannulation. Sibai AN; Loutfi E; Itani M; Baraka A Middle East J Anaesthesiol; 2008 Oct; 19(6):1305-20. PubMed ID: 18942245 [TBL] [Abstract][Full Text] [Related]
33. Oropharyngeal leak pressure with the laryngeal mask airway Supreme™ at different intracuff pressures: a randomized controlled trial. Zhang L; Seet E; Mehta V; Subramanyam R; Ankichetty SP; Wong DT; Chung F Can J Anaesth; 2011 Jul; 58(7):624-629. PubMed ID: 21533663 [TBL] [Abstract][Full Text] [Related]
34. LMA Supreme™ and Ambu® AuraGain™ in anesthetized adult patients: a prospective observational study. Kriege M; Piepho T; Zanker S; Alflen C; Heid F; Noppens RR Minerva Anestesiol; 2017 Feb; 83(2):165-174. PubMed ID: 27676414 [TBL] [Abstract][Full Text] [Related]
35. Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture. Sulek CA; Gravenstein N; Blackshear RH; Weiss L Anesth Analg; 1996 Jan; 82(1):125-8. PubMed ID: 8712386 [TBL] [Abstract][Full Text] [Related]
36. US-guided placement of temporary internal jugular vein catheters: immediate technical success and complications in normal and high-risk patients. Oguzkurt L; Tercan F; Kara G; Torun D; Kizilkilic O; Yildirim T Eur J Radiol; 2005 Jul; 55(1):125-9. PubMed ID: 15950110 [TBL] [Abstract][Full Text] [Related]
37. Differences in anatomical relationship between vertebral artery and internal jugular vein in children and adults measured by ultrasonography. Matsushita K; Yamaura K; Karashima Y; Akiyoshi K; Hoka S J Clin Monit Comput; 2016 Apr; 30(2):221-5. PubMed ID: 26018456 [TBL] [Abstract][Full Text] [Related]
38. Effect of Positive End-Expiratory Pressure on Overlap Between Internal Jugular Vein and Carotid Artery in Mechanically Ventilated Patients with Laryngeal Mask Airway (LMA) Insertion - A Prospective Randomized Trial. An X; Ye H; Chen J; Lu B Med Sci Monit; 2019 Mar; 25():2305-2310. PubMed ID: 30925147 [TBL] [Abstract][Full Text] [Related]
39. Optimal shoulder roll height for internal jugular venous cannulation: a study of awake adult volunteers. Chang WK; Wang YC; Ting CK; Cheng HW; Chan KH; Chen PT J Clin Anesth; 2012 May; 24(3):179-84. PubMed ID: 22301206 [TBL] [Abstract][Full Text] [Related]
40. Modified anchoring maneuver using pilot puncture needle to facilitate internal jugular vein puncture for small children. Tripathi M; Pandey M Paediatr Anaesth; 2008 Nov; 18(11):1050-4. PubMed ID: 18950328 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]