These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 26550787)

  • 1. Evaluation of Efficacy of Bone Scan With SPECT/CT in the Management of Low Back Pain: A Study Supported by Differential Diagnostic Local Anesthetic Blocks.
    Jain A; Jain S; Agarwal A; Gambhir S; Shamshery C; Agarwal A
    Clin J Pain; 2015 Dec; 31(12):1054-9. PubMed ID: 26550787
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The value of SPECT/CT in localizing pain site and prediction of treatment response in patients with chronic low back pain.
    Lee I; Budiawan H; Moon JY; Cheon GJ; Kim YC; Paeng JC; Kang KW; Chung JK; Lee DS
    J Korean Med Sci; 2014 Dec; 29(12):1711-6. PubMed ID: 25469075
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Correlation of (99m) Tc-DPD SPECT/CT Scan Findings and Diagnostic Blockades of Lumbar Medial Branches in Patients with Unspecific Low Back Pain in a Randomized-Controlled Trial.
    Freiermuth D; Kretzschmar M; Bilecen D; Schaeren S; Jacob AL; Aeschbach A; Ruppen W
    Pain Med; 2015 Oct; 16(10):1916-22. PubMed ID: 26177035
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Single photon emission computed tomography (SPECT) for low back pain induced by extension with no root sign.
    Chung CT; Wang CF; Chou CS; Wang SJ; Kao CH; Lan HC
    J Chin Med Assoc; 2004 Jul; 67(7):349-54. PubMed ID: 15510932
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The role of PET/CT in evaluation of Facet and Disc abnormalities in patients with low back pain using (18)F-Fluoride.
    Gamie S; El-Maghraby T
    Nucl Med Rev Cent East Eur; 2008; 11(1):17-21. PubMed ID: 19173183
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of topographic hybrid single-photon emission computerized tomography with computerized tomography scan in patients with and without nonspecific chronic low back pain. A prospective comparative study.
    Van de Kelft E; Verleye G; Van de Kelft AS; Melis K; Van Goethem J
    Spine J; 2017 Oct; 17(10):1457-1463. PubMed ID: 28495243
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hybrid Bone SPECT/CT Imaging in Evaluation of Chronic Low Back Pain: Correlation with Facet Joint Arthropathy.
    Russo VM; Dhawan RT; Baudracco I; Dharmarajah N; Lazzarino AI; Casey AT
    World Neurosurg; 2017 Nov; 107():732-738. PubMed ID: 28847557
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single photon emission computerized tomography (SPECT) scan-positive facet joints and other spinal structures in a hospital-wide population with spinal pain.
    Makki D; Khazim R; Zaidan AA; Ravi K; Toma T
    Spine J; 2010 Jan; 10(1):58-62. PubMed ID: 19643679
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Relevance of nerve blocks in treating and diagnosing low back pain--is the quality decisive?].
    Hildebrandt J
    Schmerz; 2001 Dec; 15(6):474-83. PubMed ID: 11793154
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The positive prediction of single photon emission computed tomography/ computed tomography (SPECT/CT) in the outcome of intervention for cervical facet pain.
    Nolan JE; Sundet AD; Kagan BD; Lake TJ; Krag MH; Lunardini DJ
    Spine J; 2022 Oct; 22(10):1622-1627. PubMed ID: 35537654
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The role of bone SPECT/CT in the evaluation of painful joint prostheses.
    Arıcan P; Okudan Tekin B; Şefizade R; Naldöken S; Baştuğ A; Özkurt B
    Nucl Med Commun; 2015 Sep; 36(9):931-40. PubMed ID: 26049374
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interobserver reliability in the interpretation of diagnostic lumbar MRI and nuclear imaging.
    Mulconrey DS; Knight RQ; Bramble JD; Paknikar S; Harty PA
    Spine J; 2006; 6(2):177-84. PubMed ID: 16517390
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Utility of single photon emission computed tomography/computed tomography imaging in evaluation of chronic low back pain.
    Harisankar CN; Mittal BR; Bhattacharya A; Singh P; Sen R
    Indian J Nucl Med; 2012 Jul; 27(3):156-63. PubMed ID: 23919068
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Application of SPECT bone scan for multiple myeloma].
    Hu S; Deng HY; Li XH
    Hunan Yi Ke Da Xue Xue Bao; 2002 Apr; 27(2):176-8. PubMed ID: 12575356
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Added value of SPECT/CT in patients suspected of having bone infection: preliminary results.
    Horger M; Eschmann SM; Pfannenberg C; Storek D; Vonthein R; Claussen CD; Bares R
    Arch Orthop Trauma Surg; 2007 Apr; 127(3):211-21. PubMed ID: 17146681
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MDP-SPECT Versus Hybrid MDP-SPECT/CT in the Evaluation of Suspected Pars Interarticularis Fracture in Young Athletes.
    Gaddikeri S; Matesan M; Alvarez J; Hippe DS; Vesselle HJ
    J Neuroimaging; 2018 Nov; 28(6):635-639. PubMed ID: 29989259
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SPECT/CT in patients with lower back pain after lumbar fusion surgery.
    Sumer J; Schmidt D; Ritt P; Lell M; Forst R; Kuwert T; Richter R
    Nucl Med Commun; 2013 Oct; 34(10):964-70. PubMed ID: 23820764
    [TBL] [Abstract][Full Text] [Related]  

  • 18. SPECT/CT Scan: A New Diagnostic Tool in Pain Medicine.
    Pendleton J; Ng A
    Curr Pain Headache Rep; 2023 Nov; 27(11):729-735. PubMed ID: 37837482
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of lumbar facet joint nerve blocks in the management of chronic low back pain: preliminary report of a randomized, double-blind controlled trial: clinical trial NCT00355914.
    Manchikanti L; Manchikanti KN; Manchukonda R; Cash KA; Damron KS; Pampati V; McManus CD
    Pain Physician; 2007 May; 10(3):425-40. PubMed ID: 17525777
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of computed tomography-single-photon emission computed tomography fusion for diagnosing painful facet arthropathy. Technical note.
    McDonald M; Cooper R; Wang MY
    Neurosurg Focus; 2007 Jan; 22(1):E2. PubMed ID: 17608336
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.